Amana DigiSmart PTC073G***XXX Product Specifications Download Page 2

P

roduct

 S

PecificationS

2

www.amana-ptac.com

SS-DPTAC

n

omenClATure

   

Basic   Model   Type

Engineering   

PTC

Standard   Cooler   PTAC

Major   &   Minor   Revisions

PTH

Standard   Heat   Pump   PTHP

DRY

Dehumid   Cooler   PTAC

Features   Code

A

Standard   Model

Cooling   Capacity

C

Corrosion   Protec>on   (Seacoast)

07

7000   BTU/h

60   Hz

D

Power   Door

09

9000   BTU/h

60   Hz

F

Fuse   Holder   (230/208   Only)

10

10000   BTU/h

50   Hz

H

Hydronic   Heat-­‐Capable

12

12000   BTU/h

50   or   60   Hz

P

Condensate   Pump   (PTH   Only)

15

14000   BTU/h

60   Hz

Q

Quiet   STC   31   Chassis

Rated   Voltage

R

RF   Antenna

2

115V,   60   Hz,   1   Ph

V

Power   Vent

3

230/208V,   60   Hz,   1   Ph

X

placeholder

4

265V,   60   Hz,   1   Ph

W

Hard-­‐Wired   (PTQC)

5

240/220V,   50   Hz,   1   Ph

Use   up   to   4   as   needed   in   alphabe>cal   order

Design   Series

Examples:

G

R-­‐410A

PTC123E50AXXX

PTC073E35CRXX

PTC123E50CXXX

PTC073E25CQRW

Heater   Size
00

No   Electric   Heat

3.5   kW   (230/208V)

15

1.5   kW

3.7   kW   (265V)

25

2.5   kW

5.0   kW

PTC

07

3

G

35

AXXX

50

35

AA

1,2,3

4

5

6

7,8,9 10,11,12,13

14

Summary of Contents for DigiSmart PTC073G***XXX

Page 1: ...es condensate from indoor cooling operation and evaporates it into the atmosphere through the condenser Digismart front desk control energy management software Room freeze protection is activated when...

Page 2: ...TU h 50 Hz H Hydronic Heat Capable 12 12000 BTU h 50 or 60 Hz P Condensate Pump PTH Only 15 14000 BTU h 60 Hz Q Quiet STC 31 Chassis Rated Voltage R RF Antenna 2 115V 60 Hz 1 Ph V Power Vent 3 230 208...

Page 3: ...7 2 2 3 6 4 4 Net Weight lbs 98 102 102 113 Ship Weight lbs 113 117 119 130 Actual vent CFM performance will vary due to application and installation conditions Notes All 265 volt models must use an...

Page 4: ...142 Actual vent CFM performance will vary due to application and installation conditions Notes All 265 volt models must use an Amana brand sub base PTSB4 E or an Amana brand hard wire kit PTPWHWK4 Mi...

Page 5: ...volts have a Leak Current Detector Interrupter LCDI power cord and meet UL 484 standards Product Specifications PTH Models Reverse Cycle Heating Performance Heating Capacity PTH073G AXXX PTH093G AXXX...

Page 6: ...ally sealed internally isolated rotary type and permanently mounted on rubber isolators No removal or adjustment of compressor hold down bolts is to be required during installation Warranty Thewarrant...

Page 7: ...er Vent Damper Must be provided to maximize ventilation air intake to up to approximately 95 CFM Power vent must be off and damper door closed when unit fan is de energized Fuse Holder included in 265...

Page 8: ...lters 1 Facing the unit pull up on the filter handles located at the front top of the unit 2 Pull each filter upward and remove 3 Clean filters with vacuum or with running water Reverse this procedure...