Amana DD01E Installation Instructions Manual Download Page 3

3

Thermostat Installation for DS01E Kit

NOTE: A DT01* must be installed on the digital PTAC unit
for the DS01* to be operable.
Skip these steps if not installing.
1. Select thermostat mounting location about five feet

above the floor, on an inside wall, out of direct sun-
light, away from sources of radiant heat (lamps, fire-
places, heating and air conditioning equipment, etc.),
away from windows or door to the outside, and avoid
areas with poor air circulation. If the PIR in the ther-
mostat is to be used with a DD01* device as a 2nd mo-
tion sensor, point the thermostat towards the area where
you are requiring additional motion sensing.

Ensure location is out of the path of foot traffic where
a person might accidentally bump into the thermostats
and damage the device.

2. Remove thermostat from mounting plate by pulling apart

at the bottom of the thermostat about 1”, and slide
thermostat up to release from the top of the mounting
plate.

3. Place thermostat mounting plate against the wall at de-

sired location and mark placement of mounting holes.
Make sure the UP arrow is pointing up on the mounting
plate.

4. If mounting in drywall, tap plastic anchors into wall. For

other surfaces, drill a 3/16” hole.

5. Screw mounting plate to the wall. DO NOT SNAP THER-

MOSTAT INTO PLACE UNTIL AFTER BINDING PROCESS.
See Binding Instructions on page 10.

6. Install four (4) AA batteries (included) into the back of

the thermostat. Terminals are marked “+” and “-” for
polarity.

NOTE: Do not install thermostat on wall plate until all con-
figuration settings and binding processes have been com-
pleted.

WIRED POWER OPTION

1. If the option for wired power is used, the two thermo-

stat wires (20 gauge minimum field supplied) can be
connected to the thermostat.

2. Route wires through the opening in the mounting plate.

3. Loosen set screws on wired terminal and insert wires

into the opening.  Tighten set screws. (See following
figure for powered connection with 2 jumpers).

4. Connect wires at PTAC unit to terminal pins C and R.

The wire harness kit PWHK01C is required for this con-
nection.

TWO JUMPERS

FACTORY DEFAULT

“BATTERY”

BATTERY CONNECTION

NOTE:  For battery connection the 2 jumpers must be posi-
tioned as shown above, with jumpers on the center & left
pins.

TWO JUMPERS MOVED TO

“EXT POWR”

TERMINAL BLOCK

POWERED CONNECTION

NOTE:  For powered connection, the 2 jumpers must be
positioned as shown above, with jumpers on the center &
right pins.

Summary of Contents for DD01E

Page 1: ...installation or repair it is possible to place yourself in a position which is more hazardous than when the unit is in operation Remember it is your responsibility to install the product safely and t...

Page 2: ...r at the fuse box or circuit breaker 2 If the cabinet front is screwed to the chassis remove the 1 4 screw or screws See following figure Front Mounting Screw accessed through louvers 3 Remove cabinet...

Page 3: ...plate 4 If mounting in drywall tap plastic anchors into wall For other surfaces drill a 3 16 hole 5 Screw mounting plate to the wall DO NOT SNAP THER MOSTAT INTO PLACE UNTIL AFTER BINDING PROCESS See...

Page 4: ...door frame the sensor will need to be mounted on the wall next to the door In these cases a wired magnet a field supplied single pole single throw wired magnet can be recessed or surface mounted andw...

Page 5: ...r where it will be as close as possible to the bottom of the motion sensor but no more then 1 8 from the bottom center of the sensor DD01E or DD01F when the door is closed Select the correct slot in t...

Page 6: ...Screw location located on each side of sensor SIDE VIEW P O S I T I O N A P O S I T I O N B P O S I T I O N C MAGNET SLOTS MAGNET HOLDER TOP VIEW INSTALL THE MAGNET IN THE CORRECT SLOT 15 16th FROM B...

Page 7: ...oor frame POSITION A Spacers Two 2 1 4 spacers are included in kit CONSTRUCTION STYLE 4 Place magnet in Position A in instances when the door frame extends into the room beyond the door NOTE Two 2 1 4...

Page 8: ...cally self configure to activate pre configured energy management routine when the DD01E or DD01F is installed and bound to the PTAC Additionally the setback times and setback temperatures can be chan...

Page 9: ...s the HEAT key until appears then press the up and down arrows to select 01 3 If a room contains more than one unit a suite a suffix must also be entered to identify which unit is in the main room and...

Page 10: ...lease the white button a second time Skip this step if there is no thermostat 3 Press and then immediately release the white tactile button on the back of the DD01 motion sensor or should now be displ...

Page 11: ...00 99 00 99 C5 Room I D Digit 3 4 00 99 00 99 C6 Wired or Wireless Occupancy 0 Off 1 On 18 18 Hour Automatic Entry C8 Temp Limiting Cool 60 72 60 72 C9 Temp Limiting Heat 68 90 80 68 90 80 Cd English...

Page 12: ...back temperature press the HEAT key until feature code comes up To scroll to a previously viewed feature codes press the COOL key Once you have scrolled to the feature press either the up or down arr...

Page 13: ...10 To exit configuration mode Press the OFF key NOTE Configuration feature mode will also automatically exit if no keys are pressed for a period of two 2 minutes The changes made in configuration mode...

Page 14: ...between the equipment and all persons This equipment is authorized for use under the United States Federal Communication Commission Rules and Regulations Code of Federal Regulations Chapter 47 part 1...

Page 15: ...15 THIS PAGE LEFT BLANK INTENTIONALLY...

Page 16: ...k of Maytag Corporation or its related companies and is used under license to Goodman Company L P Houston TX All rights reserved PTAC Direct Sales Inc 185 S Kimball Ave Suite 130 Southlake TX 76092 87...

Reviews: