WIRING DIAGRAMS
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
87
A/GSXC18 & A/GSZC18
A/GSXC16060 & A/GSZC16060
W
IRING CODE
FACT
OR
Y
W
IRING
HIGH
VO
LT
AG
E
LO
W
VOLTAG
E
HIGH
VO
LT
AG
E
FIELD
OP
TIONA
L
HIGH
VOLTAGE
OP
TIONA
L
LO
W
VOLTAG
E
CO
LO
R C
O
DE
BK --
------------- BLACK
BL --
------------- BLUE
BL/PK --
--------
BLU
E/
PINK STRIPE
BR -------------- BR
OW
N
OR -
------------
-ORANG
E
PU -------------
-P
URPL
E
RD -------------- RED WH
-------------
WH
IT
E
YL --------------- Y
ELLO
W
YL/PK ---------- YELLO
W/
PINK
STRIP
E
GR/
YL
--
-------
- GREEN
/ YELL
OW
STRIP
E
GY
--
------------- GR
AY
1
3
4
6
E51
E16
GR
/Y
L
BL
BR
RELAY
RELAY
RELAY
HERM
CO
M
START
RU
N
230 VAC SUP
PL
Y
L1
L2
E13
L2 OUT
L2
L1
E10
R
C
START
E5
E8
CAP CO
M
E17
ST
ART
RLY
WH
FAN RU
N
RELAY
E29
E28
E26
E9
E23
E22
E24 HIG
H
RVS
LPCO
HP
CO
OAS
OCS
(HEAT
PU
MP ON
LY
)
WH
BL
BL WH
YL
YL
LO
W
VOLT
AGE
BARRIE
R
BL/P
K
BK
YL
/P
K
BK
YL
/PK
BK
RD
BK
BK
BK
BL/PK
RCC
F
BK
YL
RD
O L Y2 Y1 W1 C
O L (OPTIONAL) Y2 Y1 W1
C
LEGAC
Y
INDOOR
THERMO
ST
AT
2 1
C R 2 1
R
R
C
INDOOR P
OW
ER SUP
PL
Y
24 VAC
CO
MMUNICATING
IN
DOOR
THERMOS
TA
T
TO
INDOOR
CO
MMU
NICATING PCB
FR
OM
OUTDOO
R
UNIT
GN
D
L1 L2
BK
YL
YL
CM
RES
2
5
1
SR
SC
OP
TIONA
L
HARD START
L1
L2
K2
C
R
S
COMP
R
S
1
2
5
CCH
SC
C
UC CONTROL
HERM
CAP COM
SR
OPTIONAL HARD
START
K5
ECM
FAN
MOTOR
C
CHS
BK
BK
RD
RD
RD
YL
BK
RD
0140R00615- A
B
K
G
Y
FR
OM
OUTDOOR UNIT
R
GR
/Y
L
BK
RD
LPS
HPS
RVS (HP ONL
Y)
CO
M
PO
NEN
T
CO
DE
C --------------
- CONTACTOR
CH ------------- CRAN
KCAS
E
HEATE
R
CHS
----------- CR
ANKCASE HEAT
ER
SW
ITCH
CM ------------
CON
DENSER FAN MOT
OR
CO
MP -------- COMP
RESSO
R
CS -
-----------
- COMPRESS
OR SOLENOI
D
DT ------------- DISC
HARGE THE
RM
OS
TA
T
HPS --
--------
-H
IGH PRES
SURE SW
ITC
H
IO --
-----------
INTERNAL OVERLOAD
LPS --
------- LO
W
PRESSURE S
W
ITC
H
OAS ----------
OUTDOOR
A
IR SENSOR
OCS --
--------
OUTDOOR CO
IL
TEMP SENSOR
RCCF --
------
R
UN
CAPACITOR FOR COMP
RESS
OR & FAN
RVS --
--------
REVERSIN
G
VALVE SOLENOID
SC -
---------- START
CAPACITOR FOR COMP
RESSO
R(
OPTIONAL)
SR -
----------- ST
ART RELAY
FOR COMP
RESSOR (O
PT
IONAL)
NOTES: 1. USE COP
PER SUP
PL
Y
WI
RES ONLY
.
2. USE 40VA TRANSFO
RM
ER MINIM
UM FOR
SY
STEM
3. IF DT IS NO
T PRESENT, HPS BL/PK
WI
RE GOES DIRECTLY
TO
TER
MINAL E29.
4. CONTROL
S SHO
WN
W
ITH THERMOS
TAT IN "OFF
" POSITION.
5. CO
MM
ON SIDE OF 24VAC CONTROL CI
RC
UIT MUST BE
GRO
UN
DE
D.
6. USE N.E.C. CLASS 2 W
IRES
.
7. COM
PRESSOR W
IRE TO BE ROUTED
TH
ROUGH CENTE
R OF
CURRENT S
EN
SOR BEFORE CONNECTI
NG TO R TE
RMINAL.
HERM
C
RUN
CAPACITOR
FAN
HIGH
VO
LT
AGE AREA
LO
W
VOLTAGE AREA
CH
S
CH
BK
RD
H
F
C
BK
YL
DT
O L
R
C
W1
Y1
E2
Y2
1
2
LP
S
E22
E23
E9
E26
E7
E1
HP
S
OC
S
OAS
DT
RVS
E28
E29
E21
CS
1
3
4
6
E51
CM
NOTE 1
(HEAT PUMP ONL
Y)
C
R
S
AU
X
CO
MP
CS
Y2
MAI
N
C
FUSE
O L
R
C
W1
Y1
E2
Y2
1
2
1 2
R
C
E25
RELAY
E7
OAT OCT
E1
CC
H
E21
UC B
OA
RD
PU
SEE NO
TE
6
SEE N
OT
E
6
SEE NOTE 6
E16
"FOR PRINT
ING PLATES
"
BK
GR
BL
RD
BK
TRANSFO
RM
ER
RD
CO
M
20
8
240
24
BR
BK
EQUI
PM
EN
TG
RO
UN
D
SEE NOTE
1
SEE NO
TE
1
SEE NO
TE
6
TO
FIELD LOW
VOLTAGE CO
NTROL
WI
RES. SEE
NOTES 2 AND 5
Summary of Contents for ASXC16
Page 4: ...PRODUCT IDENTIFICATION 4 ...
Page 5: ...PRODUCT IDENTIFICATION 5 ...