Specifi cation Sheet
SS-ASH13
www.amana-hac.com
7
P
ERFORMANCE
R
ATINGS
(
CONT
.)
Heat
Pump
Coil / Air Handler
Total
BTU/h
Sensible
BTU/h
SEER EER
Heating Capacity
dBs
47° F
(Btuh)
47°F
(COP)
HSPF
17°F
(Btuh)
17°F
(COP)
ASH130481A* (cont.)
CHPF060D2* / CHPF4EEP
45,000
34,000
13.0
12
43,000
3.50
8.2
27,000
2.40
76
CHPF060D2*
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
CHPF4860D6A* + A*V80905C**
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
CHPF060D2*
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
CHPF4860D6A* + A*V81155C**
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
CHPF060D2*
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
CHPF4860D6A* + A*V90905D**
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
CHPF060D2*
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
CHPF4860D6A* + A*V91155D**
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
H61F / CSCF4860N6A* + EEP
45,000
34,000
13.0
12
43,000
3.50
8.2
27,000
2.40
H61F / CSCF4860N6A* + A*V80905C**
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
H61F / CSCF4860N6A* + A*V81155C**
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
H61F / CSCF4860N6A* + A*V90905D**
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
H61F / CSCF4860N6A* + A*V91155D**
45,000
34,000
13.5
12
43,000
3.50
8.3
27,000
2.40
CA*F061*2* / CA*F4860 *6A* + MBE2000
45,000
34,000
14.0
12
43,000
3.60
8.4
27,000
2.50
ASH130601A*
AEPT060-00*-1* / AEPF42601A*
55,500
40,000
13.3
12
55,500
3.60
8.6
35,000
2.60
77
ARPF060-00B-1* / ADPF48601A*
55,500
40,000
13.0
12
55,500
3.50
8.5
35,000
2.50
ARPT061-00*-1* / ARPF48601A*
55,500
40,000
13.0
12
55,500
3.50
8.5
35,000
2.50
ARUF061-00*-1* / ARUF48601A*
55,500
40,000
13.0
12
55,500
3.50
8.5
35,000
2.50
CA*F061*2* / CA*F4860 *6A* + EEP
55,500
40,000
13.0
12
55,500
3.50
8.5
35,000
2.50
CA*F061*2* / CA*F4860*6* + A*V80905C**
55,500
40,000
13.3
12
55,500
3.50
8.5
35,000
2.50
CA*F061*2* / CA*F4860*6* + A*V81155C**
55,500
40,000
13.3
12
55,500
3.50
8.5
35,000
2.50
CA*F061*2* / CA*F4860*6* + A*V9115D**
55,500
40,000
13.3
12
55,500
3.50
8.5
35,000
2.50
CHPF060D2* / CHPF4860D6A* + EEP
55,500
40,000
13.0
12
55,500
3.50
8.5
35,000
2.50
CHPF060D2*
55,500
40,000
13.3
12
55,500
3.50
8.5
35,000
2.50
CHPF4860D6A* + A*V80905C**
55,500
40,000
13.3
12
55,500
3.50
8.5
35,000
2.50
CHPF060D2*
55,500
40,000
13.3
12
55,500
3.50
8.5
35,000
2.50
CHPF4860D6A* + A*V81155C**
55,500
40,000
13.3
12
55,500
3.50
8.5
35,000
2.50
CHPF060D2*
55,500
40,000
13.3
12
55,500
3.50
8.5
35,000
2.50
CHPF4 A*V9115D**
55,500
40,000
13.3
12
55,500
3.50
8.5
35,000
2.50
H61F / CSCF4860N6A* + EEP
55,500
40,000
13.0
12
55,500
3.50
8.5
35,000
2.50
H61F / CSCF4860N6A* + A*V8090C**
55,500
40,000
13.3
12
55,500
3.50
8.5
35,000
2.50
H61F / CSCF4860N6A* + A*V81155C**
55,500
40,000
13.3
12
55,500
3.50
8.5
35,000
2.50
H61F / CSCF4860N6A* + A*V91155D**
55,500
40,000
13.2
12
55,500
3.50
8.5
35,000
2.50
CA*F061*2* / CA*F4860 *6A* + MBE2000
55,500
40,000
13.5
12
55,500
3.60
8.6
35,000
2.60
NOTES:
1) Certified per ARI 210/240 @ 80 °F/67 °F/95 °F
2) Seasonal Energy Efficiency Ratio
3) Energy Efficiency Ratio @ 80 °F/67 °F/95 °F
4) HSPF = Heating Seasonal Performance Factor
5) Order the EEP from the Service Department using Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not
interchangeable with B13707-35S.
When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size.