7
PRODUCT DIMENSIONS
AMS8
For installations in Canada, the GMS furnaces are certifed only to 4,500 ft.
* Negative pressure readings are in inches of water column (*w.c.)
Model
Trip Point
ID Blow er
Press ure
Switch
ID Blow er
Pressure
Switch
Part #
AMS8040 3AX
-0.7 0
B1370158
AMS8060 3AX
-0.7 5
B1370179
AMS8060 4BX
-0.7 5
B1370179
AMS8080 4BX
-0.7 0
B1370158
AMS8080 5CX
-0.7 5
B1370179
AMS8100 5CX
-0.7 0
B1370158
AMS8120 5DX
-0.8 0
0130F00042
AMS81405DN
-0.8 0
0130F00042
Pressure Switch Trip Points
Part Number
20162901
20162904
20162903
O pen Setting (°F)
210
150
160
AM S80403AX
1
---
---
AM S80603AX
---
1
---
AM S80604BX
---
1
---
AM S80804BX
---
1
---
AM S80805CX
---
---
1
AM S81005CX
---
1
---
AM S81205DX
---
---
1
AM S81405DN
---
---
1
PRIMARY LIMIT
Part Number
10123529
Open Setting (°F)
300
AMS80403AX
2
AMS80603AX
2
AMS80604BX
2
AMS80804BX
2
AMS80805CX
2
AMS81005CX
2
AMS81205DX
2
AMS8140 5DN
2
ROLLOUT LIMIT SWITCHES
Part Number
0130F00038
Open Setting (°F)
120
AMS80403AX
1
AMS80603AX
1
AMS80604BX
1
AMS80804BX
1
AMS80805CX
1
AMS81005CX
1
AMS81205DX
1
AMS8140 5DN
1
AUXILIARY LIMIT SWITCHES