BLOWER PERFORMANCE SPECIFICATIONS

12

1.

CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return
filters, this chart assumes both filters are installed.

2.

All furnaces ship as high speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.

3.

For most jobs, about 400 CFM per ton when cooling is desirable.

4.

INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

5.

The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded
area indicates ranges in excess of maximum external static pressure allowed when heating. The data for 0.6" w.c. to 0.8" w.c. is shown for
air conditioning purposes only.

6.

The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly de-rated unit will have approximately the same
temperature rise at a particular CFM, while the ESP at that CFM will be lower.

Tons AC

at 0.5"

0.6

0.7

0.8

ESP

CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

HIGH

3.0

1352

29

1318

30

1260

31

1202

33

1128

35

1044 955

853

AMH950453BXA*

MED 2.5

1214

32

1172

34

1123

35

1064

37

1012

39

938

859

741

(MED-HI)

MED-LO

2.0

997

40

994

40

960

41

923

43

884

45

817

741

611

LOW

1.5

757

52

753

52

734

54

704

56

674

59

620

524

438

HIGH

3.0

1449

41

1409

42

1326

45

1273

47

1201

49

1194 1136 1018

AMH950703BXA*

MED

2.5

1192

50

1172

51

1141

52

1094

54

1046

57

973

904

793

(MED-HI)

MED-LO

2.0

981

61

962

62

943

63

917

65

888

67

830

764

665

LOW

1.5

750

79

730

81

714

83

692

86

657

90

620

570

502

HIGH

4.0

2069

29

1965

30

1871

32

1756

34

1661

36

1549 1415 1275

AMH950704CXA*

MED

3.5

1752

34

1724

34

1667

36

1603

37

1488

40

1402 1290 1082

(MED-HI)

MED-LO

3.0

1437

41

1437

41

1417

42

1369

43

1320

45

1256 1140 984

LOW

2.5

1184

50

1177

50

1161

51

1132

52

1095

54

1047 928

837

HIGH

4.0

1970

40

1874 342 1757

45

1667

48

1566

51

1431 1334 1182

AMH950904CXA*

MED 3.5

1713

46

1650

48

1572

50

1510

52

1418

56

1313 1211 1079

(MED-HI)

MED-LO

3.0

1439

55

1412

56

1370

58

1327

60

1260

63

1166 1078 956

LOW

2.5

1183

67

1155

69

1122

74

1108

72

1062

75

1011 931

816

HIGH

5.0

2147

37

2114

37

2057

39

2030

39

1978

40

1889 1784 1713

AMH950905DXA*

MED 4.0

1675

47

1686

47

1640

48

1623

49

1557

51

1501 1455 1360

(MED-HI)

MED-LO

3.5

1489

53

1470

54

1436

55

1409

56

1361

58

1318 1243 1130

LOW

3.0

1307

61

1265

63

1234

64

1203

66

1168

68

1096 1053 991

HIGH

5.0

2134

46

2103

47

2029

48

1941

51

1906

51

1818 1733 1625

AMH951155DXA*

MED 4.0

1678

58

1643

60

1643

60

1577

62

1527

64

1489 1423 1339

(MED-HI)

MED-LO

3.5

1453

68

1440

68

1426

69

1363

72

1349

73

1314 1253 1205

LOW

3.0

1259

78

1239

79

1220

80

1181

83

1159

85

1118 1082 1015

 BLOWER PERFORMANCE

0.1

0.2

0.3

0.4

0.5

(CFM & Temperature Rise vs. External Static Pressure)

Model

Heating Speed

As Shipped

Motor 

Speed

EXTERNAL STATIC PRESSURE (Inches Water Column)

(

)

Summary of Contents for AMH95 Series

Page 1: ...sted on page 3 Copyright 2006 2007 2009 2010 Goodman Company L P TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL AL AL is a trademark of Maytag Corporation and is used under license to Goodman Company L P All rights reserved This manual is to be used by qualified professionally trained HVAC technicians only Goodman does not assume any responsibility for property ...

Page 2: ...onnect ALL power before servicing or installing this unit Multiple power sources may be present Failure to do so may cause property damage personal injury or death Installation and repair of this unit should be performed ONLY by individuals meeting the require ments of an entry level technician at a minimum as specified by the Air Conditioning Heating and Refrigera tion Institute AHRI Attempting t...

Page 3: ...low these regulations may harm the environment and can lead to the imposition of substantial fines These regulations may vary by jurisdiction Should questions arise contact your local EPA office WARNING WARNING Do not connect or use any device that is not design certified by Goodman for use with this unit Serious property damage personal injury reduced unit performance and or hazardous conditions ...

Page 4: ...arts in Service Instructions General Operation The AMH95 furnaces are equipped with an electronic igni tion device used to light the burners and an induced draft blower to exhaust combustion products An interlock switch prevents furnace operation if the blower door is not in place Keep the blower access door in place except for inspection and maintenance This furnace is also equipped with a self d...

Page 5: ...Gas Line Entrance 14 Flue Pipe Connection Alternate 15 Rubber Elbow 16 Induced Draft Blower 17 Electrical Connection Inlets Alternate 18 Coil Front Cover Pressure Tap 19 Coil Front Cover Drain Port 20 Drain Line Penetrations 21 Drain Trap 22 Blower Door Interlock Switch 23 Capacitor 24 Integrated Control Module with fuse and diagnostic LED 25 24 Volt Thermostat Connections 26 Transformer 40 VA 27 ...

Page 6: ...UNFOLDED FLANGES 1 FOLDED FLANGES UNFOLDED FLANGES FOLDED FLANGES AIR DISCHARGE AIR DISCHARGE Cabinet Size A B C D E 20 7 16 AMH950453BXA AMH950703BXA AMH950704CXA AMH950904CXA AMH950905DXA AMH951155DXA 16 19 1 2 23 17 1 2 21 13 5 8 17 1 2 20 7 8 All dimensions are in inches 24 1 2 12 1 8 16 19 3 8 12 15 16 15 15 16 ...

Page 7: ...BD TBD AMH951155DXA 1 30 1 10 0 75 0 60 0 60 20197310 1 10 0130F00000P TBD TBD TBD NEGATIVE PRESSURE ID BLOWER WITH FLUE FIRING TYPICAL SEA LEVE DATA 2 NEGATIVE PRESSURE COIL COVER WITH FLUE FIRING TYPICAL SEA LEVE DATA 2 NEGATIVE PRESSURE COIL COVER WITH FLUE NOT FIRING TYPICAL SEA LEVEL DATA 1 2 Data given is the least negative pressure required for pressure switch to remain closed PRESSURE SWIT...

Page 8: ...0453BXA 1 AMH950703BXA 2 AMH950704CXA 2 AMH950904CXA 2 AMH950905DXA 2 AMH951155DXA 2 ROLLOUT LIMIT SWITCHES Part Number 10123535 10123519 Open Setting F 150 160 AMH950453BXA 1 AMH950703BXA 1 AMH950704CXA 1 AMH950904CXA 1 AMH950905DXA 1 AMH951155DXA 1 AUXILIARY LIMIT SWITCHES ...

Page 9: ... C D heights have an insulated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor unit C A P F 1824 A 6 A PRODUCT TYPE C Indoor Coil CABINET FINISH U Unpainted P Painted N Unpainted Case EXPANSION DEVICE F Flowrater NOMINAL CAPACITY RANGE 13 SEER 1824 1 1 2 to 2 Tons 3030 2 1 2 Tons 3636 3 Tons 3642 3 to 3 1 2 Tons 374...

Page 10: ...nimum Filter Area in2 Based on 600 ft min filter face velocity Minimum filter area dictated by heating airflow requirement 600 800 1000 1200 1400 1600 2000 0453BXA 194 194 240 288 0703BXA 324 324 324 336 0704CXA 291 291 336 384 0904CXA 432 432 432 432 0905DXA 388 388 388 480 1155DXA 486 486 486 486 Input__Airflow COOLING AIRFLOW REQUIREMENT CFM 600 800 1000 1200 1400 1600 2000 0453BXA 388 388 480 ...

Page 11: ...e with all national and or local electrical codes Use copper wire only AMH95 MODEL AMH95 0453BXA AMH95 0703BXA AMH95 0704CXA AMH95 0904CXA AMH95 0905DXA AMH95 1155DXA Btuh Input US 46 000 69 000 69 000 92 000 92 000 115 000 Output US 44 400 66 400 66 900 89 000 88 400 110 500 Input CAN 46 000 69 000 69 000 92 000 92 000 115 000 Output CAN 44 400 66 400 66 900 89 000 89 400 110 500 A F U E 95 0 95 ...

Page 12: ...4 54 704 56 674 59 620 524 438 HIGH 3 0 1449 41 1409 42 1326 45 1273 47 1201 49 1194 1136 1018 AMH950703BXA MED 2 5 1192 50 1172 51 1141 52 1094 54 1046 57 973 904 793 MED HI MED LO 2 0 981 61 962 62 943 63 917 65 888 67 830 764 665 LOW 1 5 750 79 730 81 714 83 692 86 657 90 620 570 502 HIGH 4 0 2069 29 1965 30 1871 32 1756 34 1661 36 1549 1415 1275 AMH950704CXA MED 3 5 1752 34 1724 34 1667 36 160...

Page 13: ...10 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 ...

Page 14: ...T COVER PRESSURE SWITCH N O C GY BK PLUG CONNECTION FIELD SPLICE SWITCH TEMP OR 24V THERMOSTAT CONNECTIONS GR GND 115 VAC 24 VAC BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR OPEN DOOR SWITCH BK GND L N WH JUNCTION BOX 1 OR ID BLOWER PRESSURE SWITCH HEAT H GND WH RD WH GND BURNER COMPARTMENT BLOWER COMPARTMENT NOTE 4 SEE N O COOL H BK HI BR BR CAPACITOR YL WH YL BL PU RD OR PK BK WH WH BLOWER INDU...

Page 15: ...ON DEVICE WH JUNCTION BOX OR ID BLOWER PRESSURE SWITCH HEAT H GND WH RD WH GND BURNER COMPARTMENT BLOWER COMPARTMENT NOTE 4 SEE N O COOL H BK HI BR BR CAPACITOR YL WH YL CONTROL PRIMARY LIMIT AUTO RESET BL PU MANUAL RESET ROLLOUT LIMIT CONTROL S RD OR PK BK WH WH BLOWER INDUCED DRAFT MANUAL RESET AUXILIARY LIMITS 1 IN UPFLOW BLOWER DECK 2 IN C FLOW BLOWER HOUSING C CIRCULATOR BLOWER FS LIMIT CONTR...

Reviews: