WIRING DIAGRAMS

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

HIGH VOL

T

A

G

E

!

DIS

C

ONNECT

 AL

L

 POW

E

R BEF

O

RE

 SERVICI

NG OR IN

S

T

A

L

L

IN

G

 T

H

IS

UNIT

 M

U

L

T

IPL

E

 PO

W

E

R SO

UR

CES M

A

Y BE P

R

ESEN

T

 F

A

IL

URE 

T

O

DO

 SO

 M

A

Y CAUS

E PRO

P

ERTY DAM

AG

E, 

PERSO

NAL

 I

N

J

U

R

Y

 O

R

 DE

A

T

H

.

AMH8_CA/CB

CAP

B

K

 (

H

I)

AUXILIARY

PROPERLY POLARIZED AND GROUNDED.

SERVICING.WIRING TO UNIT MUST BE

WARNING:DISCONNECT POWER BEFORE

XFMR

BK

115V

24V

BR

LIMITS

 WH

 (N
)

RD

 (

L

O

W
)

OR(M

ED
 L

O

W
)

BL
 (

M

ED)

BL
O

W
E

R

CI
C

U

L

A

T

O

R

24
V T

H

ERM

O

S

T

A

CO

NNE

CT
IO

NS

RO2 (11)

GND (8)

HUMIDIFIER

XFMR (6)

GND

G

C

W

Y

TO
MICRO

R

MVL (2)

MVC (9)

PS (10)

PSO (4)

HLI (7)

HLO (1)

CONTROL MODULE

INTEGRATED

NO

SWITCH

PRESSURE

ID BLOWER

VALVE

M1

GAS

C2

C

115 VAC

FLAME SENSOR

FP

XFMR-H

XFMR (3)

RO1 (5)

24 VAC

HOT SURFACE

IGNITER

IN
T

E

G

R

A

T

E

D

 C
O

NT
RO

MO

D

U

L

E

BR

BR

IGN

IND

ID
BLWR

CIRCULATOR

BLWR

TRANSFORMER

40 VA

XFMR-N

IN
T

E

G

R

A

T

E

D

 C

O

N

T

RO

L

 M
O

DU
L

E

CIR-N

5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

ON SOME MODELS

HUMIDIFIER

24 VAC

INDUCED DRAFT

°C. USE COPPER CONDUCTORS ONLY.

BLOWER COMPARTMENT

BURNER COMPARTMENT

   REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE

   CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART)

   REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE

4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION

INTEGRATED CONTROL

       INTERNAL TO

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

BLOWER

PRIMARY LIMIT

WH

GR

BK

IGNITER

SURFACE

HOT

PU

RD

15 PIN PLUG

C

NO

SWITCH

PRESSURE

BR

SENSOR

FLAME

BK

WH

ROLLOUT LIMITS

   RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND

SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)

    7 FLASHES = LOW FLAME SIGNAL

    5 FLASHES = FLAME SENSE  WITHOUT GAS  VALVE

    4 FLASHES = OPEN  HIGH  LIMIT

   3 FLASHES = PRESSURE SWITCH STUCK OPEN

   2 FLASHES = PRESSURE SWITCH STUCK CLOSED

   STEADY ON = NORMAL OPERATION

OFF         = CONTROL FAILURE

5

   1 FLASH   =

0

1

2

3

4

PU

   6 FLASHES =  OPEN ROLLOUT OR OPEN FUSE

COLOR CODES:

PU PURPLE

OR  ORANGE

YL  YELLOW

6

7

8

BK BLACK

GR GREEN

BR BROWN

PK PINK

RD  RED

GY GRAY

BL BLUE

WH  WHITE

PU

   RATING OF AT LEAST 105

NOTES:

TO

 

115VAC/

 

1

Ø

 

/60

 

HZ

 

POWER

 

SUPPLY WITH

OVERCURRENT

 

PROTECTION

 

DEVICE

JUNCTION BOX

SWITCH

LINE-H

DOOR

L

GND

LINE-N

DISCONNECT

N

SWITCH

 

(TEMP.)

FIELD

 

SPLICE

SWITCH

 

(PRESS.)

PROT.

 

DEVICE

 

OVERCURRENT

EQUIPMENT

 

GND

TERMINAL

JUNCTION

HI

 

VOLTAGE

 

FIELD

HI

 

VOLTAGE

 

(115V)

LOW

 

VOLTAGE

 

FIELD

LOW

 

VOLTAGE

 

(24V)

PLUG

 

CONNECTION

IGNITER

FIELD

 

GND

IND-N

IGN-N

JUNCTION

BOX

OVERCURRENT PROTECTION

POWER SUPPLY WITH

TO 115 VAC/ 1/60HZ

GND

LINE-N

LINE H

DEVICE

DOOR SWITCH

WH

BK

SWITCH LOCATED IN BLOWER

COMPARTMENT ON SOME MODELS

RD

RD

BL

PU

YL

OR

BR

(SINGLE CONTROL ON SOME MODELS)

PARK

7

8

6

5

4

C

G

R

W

Y

5 MIN

2 STG

MODE

2

1

3

2

1

CONTROL MODULE

INTEGRATED

PM

1

HI

C

3

2

2 STAGE

GAS VALVE

WH

24 VAC

HUMIDIFIER

RD

HI

MVH (12)

AIR CLEANER

ELECTRONIC

EAC-N

EAC-H

6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH

FOR MORE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT INPUTS).

WH

BL

BR

WH

BL

BK

BK

YL

YL

RD

YL

YL

PU

OR

WH

WH

WH

WH

YL

BL

RD

C

    8 FLASHES = CHECK  IGNITER OR IMPROPER GROUND

Summary of Contents for AMH8

Page 1: ...ts related companies and is used under license to Goodman Company L P Houston TX All rights reserved Copyright 2009 2010 Goodman Company L P Refer to Service Manual RS6610004 for installation operatio...

Page 2: ...repair this unit without such background may result in product damage personal injury or death Goodman will not be responsible for any injury or property damage arising from improper service or servi...

Page 3: ...and disposal of refrigerants introduced into this unit Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines These regulations may vary by j...

Page 4: ...f the blower door is not in place Keep the blower access door in place except for inspection and maintenance This furnace is also equipped with a self diagnosing elec tronic control module In the even...

Page 5: ...air as altitude increases The kit will provide the proper design certified input rate within the specified altitude range 2000 3000 4000 4500 5000 6000 7000 8000 US BURNER ORIFICE 44 55 44 55 45 56 4...

Page 6: ...Blower Door Interlock Switch Integrated Control Module Transformer Circulator Blower 1 2 3 4 5 6 7 8 9 Upflow Horizontal 1 Tubular Heat Exchanger 2 Pressure Switch 3 Flue Pipe Connection 4 Induced Dr...

Page 7: ...7 AMH8 MODELS A B AMH80453AX AMH80703AX 14 12 1 2 AMH80704BX AMH80903BX AMH80904BX 17 1 2 16 AMH80905CX AMH81155CX 21 19 1 2 AMH81405DX 24 1 2 23 All dimensions are in inches Alt Gas Inlet High Volta...

Page 8: ...81405DX 0 60 013070142 PRESSURE SWITCH TRIP POINTS AND USAGE CHART SQUARE NOSE ROUND NOSE PRESSURE SWITCH TRIP POINTS AND USAGE CHART For installaions in Canada the AMH8 furnace is certified only to 4...

Page 9: ...have an insulated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor unit Coil Matches Amana brand units using R22 and...

Page 10: ...ILTER SIZE TYPE 45M 160 in2 permanent 70M 241 in2 permanent 90M 320 in2 permanent 115M 400 in2 permanent 140M 370 in2 permanent 45M 320 in2 disposable 70M 483 in2 disposable 90M 640 in2 disposable 115...

Page 11: ...nace in Low Stage Low Heat Blower Low Heat Blower Call for Heat Call for Heat Safety Circuit Check Safety Circuit Check MODE DIP SWITCH TwinComfort Note This furnace is designed to be used with a sing...

Page 12: ...0 140 000 Output Natural Gas BTUH 1 36 000 56 000 56 000 72 000 72 000 72 000 92 000 112 000 Output LP BTUH 32 000 48 000 48 000 64 000 64 000 64 000 80 000 96 000 A F U E 80 0 80 0 80 0 80 0 80 0 80...

Page 13: ...19 56 913 57 892 58 847 829 818 792 728 LOW 1 5 758 741 741 733 699 677 649 626 HIGH 4 0 2134 2100 25 2042 25 1975 26 1883 28 1786 1700 1601 M H S 80704B MED 3 5 1668 31 1663 31 1656 31 1645 32 1616 3...

Page 14: ...30 40 50 60 70 80 90 110 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 20...

Page 15: ...CIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 7 AMPS BLOWER PRIMARY LIMIT WH GR BK IGNITER SURFACE HOT PU RD 15 PIN PLUG C NO SWITCH PRESSURE BR S...

Page 16: ...ANTICIPATORONROOMTHERMOSTATAT0 7AMPS BLOWER PRIMARYLIMIT WH GR BK IGNITER SURFACE HOT PU RD 15PINPLUG C NO SWITCH PRESSURE BR SENSOR FLAME BK WH ROLLOUTLIMITS RAPIDFLASHES REVERSED115VACPOLARITY VERIF...

Page 17: ...CIR NEU K5 GAS VALVE HIGH LIMIT AUX LIMIT PRESSURE SWITCH FLAME SENSOR PROBE IGNITOR FP IGN GND MV MLV PS HLO HLI CIRCULATOR BLOWER XFMR HOT XFMR NEU 24 VAC TH RO1 RO2 R TR C Y G W COMPRESSOR CONTACTO...

Reviews: