SS-AMVM96
www.amana-hac.com
9
8 www.amana-hac.com
SS-AMVM96
P
roduCt
s
PeCiFiCAtions
P
roduCt
s
PeCiFiCAtions
ACVM96 A
irFlow
d
AtA
— C
ooling
s
Peeds
ACVM960604CX
High- or Single Stage
Low Stage
Cooling
Speed Tap
Adjust
Tap
CFM *
Cooling
Speed Tap
Adjust
Tap
CFM *
A
Minus(-)
594
A
Minus(-)
333
Normal
660
Normal
370
Plus (+)
726
Plus (+)
407
B
Minus(-)
774
B
Minus(-)
486
Normal
860
Normal
540
Plus (+)
946
Plus (+)
594
C
Minus(-)
1035
C
Minus(-)
711
Normal
1150
Normal
790
Plus (+)
1265
Plus (+)
869
D
Minus(-)
1323
D
Minus(-)
882
Normal
1470
Normal
980
Plus (+)
1617
Plus (+)
1078
* @ .1" - .8" w.c. ESP
Notes
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• Operation is recommended below .5” w.c. ESP in heating mode. Operating CFM between .5”
and .8” w.c. is tabulated for cooling purposes only.
ACVM960805DX
High- or Single Stage
Low Stage
Cooling
Speed Tap
Adjust
Tap
CFM *
Cooling
Speed Tap
Adjust
Tap
CFM *
A
Minus(-)
810
A
Minus(-)
477
Normal
900
Normal
530
Plus (+)
990
Plus (+)
583
B
Minus(-)
990
B
Minus(-)
657
Normal
1100
Normal
730
Plus (+)
1210
Plus (+)
803
C
Minus(-)
1287
C
Minus(-)
837
Normal
1430
Normal
930
Plus (+)
1573
Plus (+)
1023
D
Minus(-)
1692
D
Minus(-)
1098
Normal
1880
Normal
1220
Plus (+)
2068
Plus (+)
1342
* @ .1" - .8" w.c. ESP
Notes
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• Operation is recommended below .5” w.c. ESP in heating mode. Operating CFM between .5”
and .8” w.c. is tabulated for cooling purposes only.