Disassembly Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all earthing wires are connected before certifying unit as repaired and/or operational.
30
16023324 Rev. 0
©2004 Maytag Services
Light Bulb Sockets
1. After following procedure on removing light bulb
assembly.
2. Disconnect wires to sockets.
3. Squeeze tab on back side of socket to release it from
assembly.
4. Reverse procedure to reassemble.
PC Control Board
1. Remove light shield by sliding shield to rear to release
cover.
2. Depress with a screw driver through two slots in the
front of the light housing release tabs to release
Control Board housing.
3. Control Board housing will drop down exposing
Control Board.
4. Unplug two wire harnesses plugged into the Control
Board.
5. Release tabs holding Control Board to housing.
CONTROL BOARD
RELEASE TABS
LIGHT COVER
Mid Level Electronic Model
Light Switch
1. After following procedure on removing light bulb
assembly.
2. Disconnect wires from light switch.
3. Squeeze tab to release light switch from light
assembly.
4. Reverse procedure to reassemble.
Electronic Temp-Assure
TM
Damper Control
1. Remove louvered cover off of Damper Control
housing by squeezing down on louvers to release
from housing.
2. Remove two screws holding housing to rear wall.
3. Remove Damper Control housing.
4. Remove Foam insert by pulling it out.
5. Unplug wire harness from Damper Control.
6. Unclip Damper Control from tabs and remove.
ELECTRIC DAMPER
FOAM INSERT
DAMPER CONTROL
COVER
Fresh Food Thermistor (some models)
1. Remove light shield by sliding shield to rear to release
cover.
2. Depress with a screw driver through two slots in the
front of the light housing release tabs to release
Control Board housing.
3. Control Board housing will drop down exposing
Control Board and Thermistor.
4. Cut wires to Thermistor at Thermistor.
5. Remove Thermistor from clip.
Water Tank (some models)
1. Turn water off to unit.
2. Disconnect water line that supplys water tank from
water valve.
3. Remove compression nut off of inlet to tank.
4. Remove crispers from fresh food compartment.