Capacité de refroidissement du climatiseur
Btu/heure
Capacité de refroidissement du climatiseur
Btu/heure
Capacité de refroidissement du climatiseur
Btu/heure
150 3,600 3,900 5,000 5,800 6,100 7,100 7,100 7,400 8,400
200 4,100 4,500 5,900 6,300 6,700 8,100 7,600 8,000 9,400
250 4,500 5,000 6,700 6,800 7,300 9,000 8,100 8,600 10,300
300 4,900 5,500 7,600 7,300 7,900 10,000 8,600 9,200 11,300
350 5,300 6,000 8,500 7,800 8,500 10,900 9,100 9,800 12,200
400 5,800 6,600 9,400 8,300 9,100 11,900 9,600 10,400 13,200
450 6,200 7,100 10,200 8,700 9,600 12,800 10,000 10,900 14,100
500 6,600 7,600 11,100 9,200 10,200 13,700 10,500 11,500 15,000
550 7,000 8,100 12,000 9,700 10,800 14,700 11,000 12,100 16,000
600 7,500 8,700 12,900 10,200 11,400 15,600 11,500 12,700 16,900
650 7,900 9,200 13,700 10,700 12,000 16,600 12,000 13,300 17,900
700 8,300 9,700 14,600 11,200 12,600 17,500 12,500 13,900 18,800
750 8,800 10,300 15,500 11,700 13,200 18,500 13,000 14,500 19,800
800 9,200 10,800 16,400 12,200 13,800 19,400 13,500 15,100 20,700
850 9,600 11,300 17,300 12,700 14,400 20,300 14,000 15,700 21,600
900 10,000 11,800 18,100 13,200 15,000 21,300 14,500 16,300 22,600
950 10,500 12,400 19,000 13,700 15,600 22,200 15,000 16,900 23,500
1000 10,900 12,900 19,900 14,200 16,200 23,200 15,500 17,500 24,500
1100 11,700 13,900 21,600 15,100 17,300 25,000 16,400 18,600 26,300
1200 12,600 15,000 23,400 16,100 18,500 26,900 17,400 19,800 28,200
1300 13,400 16,000 25,100 17,100 19,700 28,800 18,400 21,000 30,100
1400 14,300 17,100 26,900 18,100 20,900 30,700 19,400 22,200 32,000
NORD OU OMBRAGÉE
EST OU SUD
OUEST
P
ièce
au
-
de
ssus
P
laf
ond
is
ol
é
P
laf
ond
non
i
s
ol
é
P
ièce
au
-
de
ssus
P
laf
ond
is
ol
é
P
laf
ond
non
i
s
ol
é
P
ièce
au
-
de
ssus
P
laf
ond
is
ol
é
P
laf
ond
non
i
s
ol
é
6XSHUILFLH
jUHIURLGLU
HQSLHGV
FDUUpV
Capacité de refroidissement du climatiseur
Btu/heure
Capacité de refroidissement du climatiseur
Btu/heure
Capacité de refroidissement du climatiseur
Btu/heure
150 4,000 4,300 5,600 6,500 6,800 8,000 8,000 8,300 9,500
200 4,500 5,000 6,600 7,100 7,500 9,100 8,600 9,000 10,600
250 5,000 5,600 7,600 7,600 8,200 10,200 9,100 9,700 11,700
300 5,500 6,200 8,600 8,200 8,900 11,300 9,700 10,400
12,800
350 6,000 6,800 9,600 8,800 9,600 12,400
10,300
11,100
13,800
400 6,500 7,400 10,600 9,400 10,300 13,500 10,900 11,800 14,900
450 6,900 8,000 11,600 9,900 10,900 14,500 11,400 12,400 16,000
500 7,400 8,600 12,600 10,400 11,500 15,600 11,900 13,000 17,100
550 7,900 9,200 13,600 11,000 12,200 16,700 12,500 13,700 18,200
600 8,400 9,800 14,600 11,500 12,900 17,800 13,000 14,400 19,300
650 8,900 10,400 15,600 12,100 13,600 18,900 13,600 15,100 20,400
700 9,400 11,000 16,600 12,700 14,300 19,900 14,200 15,800 21,500
750 9,900 11,600 17,600 13,300 15,000 21,000 14,800 16,500 22,600
800 10,400 12,200 18,700 13,800 15,700 22,100 15,300 17,200 23,600
850 10,900 12,800 19,700 14,400 16,400 23,200 15,900 17,900 24,700
900 11,400 13,400 20,700 15,000 17,100 24,300 16,500 18,600 25,800
950 11,900 14,100 21,700 15,600 17,800 25,400 17,100 19,300 26,900
1000 12,400 14,700 22,700 16,200 18,500 26,500 17,600 19,900 28,000
1100 13,300 15,900 24,700 17,300 19,700 28,600 18,700 21,200 30,100
1200 14,300 17,100 26,700 18,400 21,100 30,800 19,800 22,600 32,300
1300 15,300 18,300 28,700 19,500 22,500 32,900 21,000 24,000 34,400
1400 16,300 19,500 30,800 20,600 23,900 35,100 22,100 25,300 36,600
16
Energy Saver
Unit must be currently running in COOL mode to set EN-
ERGY SAVER. Use this mode to help reduce energy con-
sumption. In ENERGY SAVER mode as the unit maintains
room temperature the compressor and fan motor cycle on
and off. Fan motor will shut off 3 minutes after compressor.
In non-energy saver mode the fan motor runs continuously
while the compressor cycles on and off.
Press the ENERGY SAVER keypad.
Auto
(Fan Speed)
Unit must be currently running in COOL mode to set AUTO
fan speed. This setting automatically adjusts the fan speed
based on the room temperature. Two degrees or more above
your temperature setting and the fan will run on high. The fan
will run on medium speed if the room temperature is between
.1 and 1.9 degrees above your setting. If the room tempera-
ture is equal to or less than your setting, the fan will run on
low. Time between speed changes is 3 minutes.
Press AUTO.
Dehumidifier
Unit must be ON to set DEHUMIDIFIER feature. This mode
is used for removing excess moisture from the air. If the room
temperature falls one degree below your set point, the
compressor shuts off and the fan runs at low speed. A room
temperature one to three degrees above the set point makes
the compressor cycle ten minutes on and six minutes off,
while the fan runs at low speed. A room temperature more
than three degrees above set point makes the compressor
run continuously, while the fan runs in your preselected
speed. Energy Saver does not operate in this mode.
In any order.
Press DEHUMIDIFY.
Press TEMP/TIME to adjust temperature.
Press HIGH, MED, or LOW.
Fan Only
Use this setting to circulate and filter air when cooling is not
desired.
Note:
Fan only uses low and medium speeds only.
Timer On
Timer on feature is used to program the unit, to delay start
from 1 to 12 hours in advance.
To set TIMER ON feature, unit must be on.
Select the desired setting (COOL, DEHUMIDIFIER, or FAN
ONLY).
Press TIMER ON keypad. LED will display a digit from 1 to
12 (indicates hours before unit starts up)
.
Press the TEMP/TIME up or down keypad to select your
delay start, beginning now.
Note:
Unit will automatically power down 5 seconds after
accepting your TIMER ON setting.
To cancel this mode
press TIMER ON again.
Timer Off
This feature is used to preset an auto off time of up to 12 hours.
To set TIMER OFF, unit must be on.
Select desired setting (COOL, DEHUMIDIFIER, or FAN ONLY).
Press TIMER OFF keypad. LED will display a digit from 1 to 12
(Indicates hours until unit shut down)
.
Press the TEMP/TIME up or down keypad to set shut off time,
beginning now.
Note:
To cancel this mode press TIMER OFF again.
Sleep
Unit must be currently running in COOL mode to set SLEEP.
This setting is an 8 hour preset auto off. During the first hour of
SLEEP there will be a two degree rise in temperature. During
the second hour of SLEEP there will be an additional two
degree rise in temperature. During the remaining six hours of
SLEEP there will be no change in temperature.
Set desired temperature and fan speed.
Press the SLEEP keypad.
X. Full Function Remote
Duplicates every feature found on the control panel, for effort-
less environmental control at your finger tips.
A UTO
DEHUM
ENERGY
SAVER
XI. Battery Compartment
TIMER
ON
TIMER
OFF
SLEEP
MODELS: AAC051STA,
AAC081STA, AAC101STA
AAC061STA AAC121STA, AAC182STA
FAN
ONLY
AUTO
FAN
DEHUM
COOL
SLEEP
TIMER
OFF
TIMER
ON
LOW
HIGH
MED
ENERGY SAVER
ON / OFF
-
AUTO
SWEEP
FAN
ONLY
AUTO
FAN
DEHUM
COOL
SLEEP
TIMER
OFF
TIMER
ON
LOW
HIGH
MED
ENERGY SAVER
ON / OFF
-
FAN
ONLY