PRODUCT DESIGN

Rev. 1

Coil Matches:

A large array of Amana coils are available for use with the GUID furnaces, in either upflow or horizontal applications. These
coils are available in both cased and uncased models, with or without a TXV expansion device. These 80% furnaces match
up with the existing Amana coils as shown in the chart below.

Thermostats:

The following Amana Thermostats are suggested for use with the GUID Furnace Models:

Btuh

Input

Cabinet

Width

Air Flow

(tons)

CAA_F*C

Cased

A-Coils

CCA_FSC

Uncased

A-Coils

CHA_TCC

Cased

TXV A-Coils

CHA_TSC

Uncased

 TXV A-Coils

CCF_F*C

Horiz.

A-Coils

CHF_TCC

Horiz.

A-Coils

45,000

16 1/2"

1 1/2 - 3

70,000

16 1/2"

2 - 3 1/2

115,000

24 1/2"

3 - 5

CCA18FCC
CCA24FCC
CCA30FCC
CCA36FCC
CCA42FCC

CCA18FSC
CCA24FSC
CCA30FSC
CCA36FSC
CCA42FSC

CHA18TCC
CHA24TCC
CHA30TCC
CHA36TCC

CHA18TSC
CHA24TSC
CHA30TSC
CHA36TSC

CCF24FCC
CCF30FCC
CCF36FCC

CHF18TCC
CHF24TCC
CHF30TCC

90,000

20 1/2"

2 1/2 - 4

CCA30FDC
CCA36FDC
CCA42FDC
CCA48FCC

CCA48FSC

CHA42TCC

CHA42TSC

CCF24FDC
CCF36FDC
CCF42FCC
CCF48FCC 

CHF36TCC
CHF42TCC

CCA36FKC
CCA48FDC
CCA54FCC
CCA57FCC
CCA60FCC

CCA54FSC
CCA57FSC
CCA60FSC

CHA48TCC
CHA54TCC
CHA57TCC
CHA60TCC

CHA48TSC
CHA54TSC
CHA57TSC
CHA60TSC

CCF48FDC
CCF60FCC

CHF48TCC

Thermostats

Thermostat

Man/Auto

Programmable

Cool

Heat

Batt. Powered

Batt. Bkup*

Shape

Color

1213401

Man. Changeover

Yes

1

1

Yes

No

Rectangular

White

1213402

Man. Changeover

No

1

1

Yes

No

Rectangular

White

1213408

Man. or Auto Changeover

Yes

1

1

No

Yes

Rectangular

White

Summary of Contents for 40"

Page 1: ... to the appropriate Parts Catalog for part number information This manual is to be used by qualified HVAC technicians only Amana does not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person Built Better Than It Has To Be Air Conditioning Heating RT6621004 Revision1 September2000 40 80 Gas Furnaces GUID This manual r...

Page 2: ...T THIS MAY CAUSE SERIOUS INJURY OR DEATH AMANA WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCE DURES IF YOU PERFORM SERVICE ON YOUR OWN PRODUCT YOU ASSUME RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE WHICH MAY RESULT WARNING WARNING Product Type G Gas Furnace Supply Type U Upflow Horizontal Airflow Capability 30 3 0 Tons 40 4 0 ...

Page 3: ...X30 P1227002F GUID070DX40 P1227003F GUID090DX50 P1227005F GUID115DX50 P1227007F GUID070DX40 P1227009F GUID045CA30 P1229401F GUID070CA30 P1229402F GUID070CA40 P1229403F GUID090CA30 P1229404F GUID090CA50 P1229405F GUID115CA50 P1229407F GUID045CA30 P1229501F GUID070CA30 P1229502F GUID070CA40 P1229503F GUID090CA30 P1229504F GUID090CA50 P1229505F GUID115CA50 P1229507F GUID045CX30 P1229601F GUID070CX30 ...

Page 4: ...e necessary When installed in a residential garage the furnace must be positioned so the burners and ignition source are located not less than 18 inches 457 mm above the floor and protected from physical damage by ve hicles Accessibility Clearances Minimum UPFLOW HORIZONTAL LEFT HORIZONTAL RIGHT FRONT 6 1 Alcove Alcove RIGHT 0 6 12 LEFT 0 12 6 REAR 0 0 0 TOP 1 6 6 FLUE 6 2 6 2 6 2 FLOOR C C C MINI...

Page 5: ... dimensions are in inches A Raytheon Company UPFLOW FRONT VIEW A B C 3 4 D BOTTOM KNOCK OUT SUPPLY SIDE KNOCK OUT 31 34 5 8 UPFLOW RIGHT SIDE VIEW SUPPLY 28 1 4 31 5 8 37 3 8 23 1 5 8 14 23 BOTTOM KNOCK OUT 1 5 8 3 4 20 1 8 28 28 3 4 4 5 8 4 3 4 GAS SUPPLY HOLE ELECTRICAL HOLE LOW VOLTAGE ELECTRICAL HOLE HIGH VOLTAGE KNOCK OUT FOR HORIZONTAL VENTING UPFLOW LEFT SIDE VIEW 3 4 40 1 3 4 4 5 8 SIDE KN...

Page 6: ...ace of limit part 10728331 160 F Part Number 10123506 or 10123525 Open Setting F 160 Color Orange GUID045 30 1 GUID070 30 40 1 GUID090 30 50 1 GUID115 50 1 AUXILIARY LIMIT SWITCHES PRESSURE SWITCH Prod HIGH ALTITUDE KIT TRIP POINT HIGH ALTITUDE KIT LABEL COLOR GUID 10727920 HAC1PS11 10727915 0 41 HAC1PS12 10727916 ORANGE Note All negative pressure readings are in inches of water column w c 0 to 60...

Page 7: ...2 3 70 000 16 1 2 2 3 1 2 115 000 24 1 2 3 5 CCA18FCC CCA24FCC CCA30FCC CCA36FCC CCA42FCC CCA18FSC CCA24FSC CCA30FSC CCA36FSC CCA42FSC CHA18TCC CHA24TCC CHA30TCC CHA36TCC CHA18TSC CHA24TSC CHA30TSC CHA36TSC CCF24FCC CCF30FCC CCF36FCC CHF18TCC CHF24TCC CHF30TCC 90 000 20 1 2 2 1 2 4 CCA30FDC CCA36FDC CCA42FDC CCA48FCC CCA48FSC CHA42TCC CHA42TSC CCF24FDC CCF36FDC CCF42FCC CCF48FCC CHF36TCC CHF42TCC ...

Page 8: ...w c 10 50 12 50 12 50 15 50 15 50 20 50 Temperature Rise F 35 65 35 65 35 65 40 70 40 70 40 70 Pressure Switch Trip Point w c 0 55 0 55 0 55 0 55 0 55 0 55 Blower Wheel D x W 9 x 8 9 x 8 10 x 6 10 x 8 10 x 8 10 x 9 Blower Horsepower 1 3 1 3 1 2 1 2 3 4 3 4 Blower Speeds 4 4 4 4 4 4 Max CFM 0 5 E S P 1200 1290 1529 1380 1975 1985 Power Supply 115 60 1 115 60 1 115 60 1 115 60 1 115 60 1 115 60 1 Mi...

Page 9: ...70DA40 GUID070DX40 Btuh Input US 69 000 69 000 Output US 55 200 55 200 A F U E 80 80 Rated External Static w c 12 50 12 50 Temperature Rise F 35 65 35 65 Pressure Switch Trip Point w c 0 55 0 55 Blower Wheel D x W 10 x 8 10 x 8 Blower Horsepower 1 2 1 2 Blower Speeds 4 4 Max CFM 0 5 E S P 1529 1529 Power Supply 115 60 1 115 60 1 Minimum Circuit Ampacity MCA 9 9 9 9 Maximum Overcurrent Device 15 15...

Page 10: ...0 980 35 900 38 Low MED LO 2 0 935 36 910 37 885 39 845 40 790 43 710 48 LOW 1 5 700 49 685 50 665 51 635 54 575 59 425 HIGH 3 0 1555 1505 1440 35 1365 37 1290 39 1180 43 GUID070 30 MED 3 0 1325 38 1305 39 1250 41 1200 42 1140 44 1060 48 Med Lo MED LO 2 5 1090 47 1080 47 1055 48 1020 50 970 52 905 56 LOW 2 0 760 750 750 735 700 645 HIGH 3 5 1695 1625 1580 1520 1450 35 1365 37 GUID070 40 MED 3 0 14...

Page 11: ...ot recommended for this model 7 The above chart is for U S furnaces installed at 0 2000 feet At higher altitudes a properly derated unit will have approximately the same temperature rise at a particular CFM while the ESP at that CFM will be lower Note The models listed in the above airflow table use 10x8 blower assembly instead of 10x6 to achieve a full 4 tons of airflow Listed below are the model...

Page 12: ...0 110 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 ...

Page 13: ...LIMIT CONTROL BR 27 PRIMARY ROLLOUT LIMIT RL FLAME SENSOR COMBUSTION BLOWER CB DOOR SWITCH CLOSED WHEN DOOR IN PLACE 115V FIELD CONNECT AIR CIRCUL BLOWER ACB CAPACITOR CAP BR BR X F M R I G N I N D C O O L H E A T P A R K P A R K L I N E X F M R L I N E C I R W Y LOAD LINE TRANSFORMER 29 OR MED LOW 26 BK HI 23 BU MED 24 RD LOW PRESSURE SWITCH PS NC NO COM CONTROL BK 3 OR 16 BU 15 BU 25 YL 11 VT 20...

Page 14: ...AUX LIMIT CONTROL PRIMARY ROLLOUT LIMIT RL FLAME SENSOR COMBUSTION BLOWER CB DOOR SWITCH CLOSED WHEN DOOR IN PLACE 115V FIELD CONNECT CAPACITOR CAP BR BR X F M R I G N I N D C O O L H E A T P A R K P A R K L I N E X F M R L I N E C I R W Y LOAD LINE TRANSFORMER 29 OR MED LOW 26 BK HI 23 BU MED 24 RD LOW PRESSURE SWITCH PS NC NO COM CONTROL BK 3 BU 15 YL 11 VT 20 GY 47 BK 1 WH 2 WH 12 GY 25 1 4 7 1...

Page 15: ...ROL PRIMARY ROLLOUT LIMIT RL FLAME SENSOR COMBUSTION BLOWER CB DOOR SWITCH CLOSED WHEN DOOR IN PLACE 115V FIELD CONNECT CAPACITOR CAP BR BR X F M R I G N I N D C O O L H E A T P A R K P A R K L I N E X F M R L I N E C I R W Y LOAD LINE TRANSFORMER 29 OR MED LOW 26 BK HI 23 BU MED 24 RD LOW PRESSURE SWITCH PS NC NO COM CONTROL BK 3 BU 15 YL 11 VT 20 GY 47 BK 1 WH 2 WH 12 GY 25 4 7 10 11 8 5 6 9 BR ...

Page 16: ...A T INTEGRATED CONTROL MODULE INTEGRATED CONTROL MODULE GND DISCONNECT L N WARNING DISCONNECT POWER BEFORE SERVICING WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED TO 115VAC 1Ø 60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE VT 55 BU 36 OR ON OFF ON ON OFF OFF OFF GND GND DISCONNECT L 4 IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME DISCARD JUMPER BEFORE CONNECTING BLOWER LEAD...

Page 17: ...unit being serviced OPTIONAL SENSOR PARK PARK ELECTRONIC AIR CLEANER HUMIDIFIER PRESSURE SWITCH AUX LIMIT PRIMARY LIMIT FLAME TH TR RO1 HL1 PS RO2 MV MV HLO FP COOL Y HEAT W 24V POWER R BLOWER G TH HLO FP ROLLOUT SWITCH RO2 RO1 PS TR MV HL1 GND MV 120V 24V GAS VALVE HEAT COOL TRANSFORMER F F TX LINE PARK PARK HUM EAC XFMR LINE CIR N N N COOL ACB LOW ACB CN1 N N R G W Y C HUM 120VAC HEAT ACB EAC BL...

Page 18: ...bove refer to the appropriate wiring diagram for the unit being serviced HEAT COOL PARK PARK CIR NEU GAS VALVE HIGH LIMIT AUX LIMIT PRESSURE SWITCH FLAME SENSOR PROBE IGNITER FP IGN GND MVC MV PS HLO HLI CIRCULATOR BLOWER XFMR HOT XFMR NEU 24 VAC TH RO1 RO2 R TR C Y G W COMPRESSOR CONTACTOR COIL THERMOSTAT R Y G W INDUCER IND ELECTRONIC AIR CLEANER HUMIDIFIER HUM NEU HUM EAC EAU NEU ROLLOUT SWITCH...

Page 19: ...opriate wiring diagram for the unit being serviced 0005 3M K5 K2 HEAT COOL PARK PARK CIR NEU K8 GAS VALVE HIGH LIMIT AUX LIMIT PRESSURE SWITCH FLAME SENSOR PROBE IGNITOR FP IGN GND MV MV PS HLO HLI CIRCULATOR BLOWER XFMR HOT XFMR NEU 24 VAC TH RO1 RO2 R TR C Y G W COMPRESSOR CONTACTOR COIL THERMOSTAT R Y G W INDUCER IND ELECTRONIC AIR CLEANER HUMIDIFIER HUM NEU IND EAC EAU NEU K3 ROLLOUT SWITCH LI...

Reviews: