INPt
SCLE
SSI bitS
SIGN
Viewable display range
1
1
12
OFF
0
to
4095
1
-1
12
OFF
0
to
-4095
1
1
12
on
-2048
to
2047
1
-1
12
on
-2047
to
2048
1
2
12
OFF
0
to
8191
2
1
12
OFF
0
to
2047
1
1
13
OFF
0
to
8191
1
1
14
OFF
0
to
16383
1
1
20
OFF
0
to
1048575
1
1.00
20
OFF
0
to
1048.58
8192
1000
12
OFF
0
to
500
5.31
Sign bit
Display:
SIGN
Range:
on
or
OFF
Default Value:
OFF
Displays and sets the sign bit enabling. With the
SIGN
function set to
on
the data is interpreted
as a twos compliment signed number, masked to the number of bits set by the
SSI bitS
function.
See the
SSI bitS
function above for the effect of the
SIGN
setting on the values displayed for
a given number of input bits.
5.32
SSI code type
Display:
SSI CodE
Range:
bin
or
GRAY
Default Value:
bin
The input type can be set to
bin
for binary or to
GRAY
for gray code SSI to match the output
type from the sensor.
5.33
User simple scaling method
Display:
U.SCL
Range:
on
or
OFF
Default Value:
OFF
Two point scaling method using a zero or preset operation via a remote input switch or front
P
button as the first scaling point and a
F
button operation to scale as second point. This method
provides a simple scaling method without the need to enter the setup functions and is generally
used where scaling is to be changed frequently.
Note: 5 or more display digits are required to view fully some of the messages seen in this function.
26 of