CAL
ZERO
Zero reference point for
ZERO
RNGE
operation
n/a
n/a
/
USER
En4
4mA input scale
Any display
value
n/a
/
USER
En20
20mA input scale
Any display
value
n/a
/
UCAL
Uncalibrate
n/a
n/a
/
Pbut
P
button function (for
instruments with front
P
button)
NONE, Hi,
Lo, HiLo,
ZERO, dISP
,
or
CLR.t
NONE
/
R.INP
Remote input (external input)
function
NONE,
P.HLd,
d.HLd, Hi,
Lo , HiLo,
ZERO,
SP.Ac,
No.Ac,
CAL.S,
duLL, dISP
or
CLR.t
NONE
/
ACCS
Access mode
OFF, EASY,
NONE
or
ALL
OFF
/
SPAC
Setpoint access mode
(
∗
Optional
)
A1, A1-2
etc.
A1
/
SQrt
Square root mode
on
or
OFF
OFF
/
tOtI
dCPt
Total display decimal point
selection
0
to number of
display digits
minus 1
0
/
dISP
SCLE
Total display scaling factor
Any display
value
1
/
tOtI
SECS
Totaliser scaling factor
Any display
value
60
/
E.SCL
Total exponent scaling factor
0
to
9
0
/
totI
NEG
Negative total select
OFF
or
on
OFF
/
totI
RAP.F
Wrap around operation
ZERO
or
StOP
ZERO
/
CLR
totI
Clear total
n/a
n/a
/
dFIt
dISP
Default display
RAtE
or
tOtI
RAtE
/
(
∗
Optional
)—this function will only be accessible if the relevant option is fitted
PM4IVTMAN-2.3-0
13 of