© 1999 Amada
18
8.0 TROUBLESHOOTING GUIDE
TROUBLE
REMEDY
POSSIBLE CAUSE
1d. Check airflow in duct for
proper requirements.
Adjust the damper control
until the proper airflow is
achieved and the blower
fan motor amp draw is
within motor's ratings.
1e. Check that the supply
circuit has sufficient power
to run all equipment.
1. Check that the gaskets on
the filter cartridges are
facing into the cabinet first.
See Figure 5, Filter
Cartridge Replacement and
Section 7.1, Filter
Cartridges.
2. Replace the filter
cartridges. Use only Torit
Ultra-Web II FR filter
cartridges.
3. Tighten access cover knobs
securely by hand.
1. Starter kicks out (contd).
d. Blower fan damper
control not adjusted
properly.
e. Electrical circuit
overload.
1. Filter cartridges installed
improperly.
2. Filter cartridge damage,
dents in the end caps,
gasket damage or holes in
pleated media.
3. Access covers are loose.
B. Blower fan and motor
start, but do not stay
running (contd).
C. Dust discharging out clean
air outlet.