Programming:
The MPPT Charge Controller for Expion360 Lithium Batteries
Programming / Commissioning Your System - The Charge Controller
Charge Control Settings for Lithium Batteries:
1. Download the “VictronConnect” App to your phone.
2. Open the App.
3. You’ll see a selection for your SmartSolar MPPT Charger, select it.
4. Type
000000
to login for the first time.
NOTE: To change the PIN code, go back one step to the main screen. Click on the
3 buttons to the right of the controller image, and select “Reset PIN Code”.
5. Click on the
gear
in the top right corner.
6. Click on “Battery”.
7. Click on the settings and adjust them acccordingly to match below:
- Battery voltage: 12V
- Max charge current: 50A (In this example)
- Use default charge settings: OFF
- Charger: ON
- Absorption voltage: 14.20 V
- Absorption Time Limit: 01:00
- Float voltage: 13.50 V
- Equalization voltage: 14.20 V
- Auto Equalization: DISABLE (OFF)
- Temperature compensation: OFF
Download
VictronConnect
In App Store
Device List within
VictronConnect
MPPT Charge Controller
Screen
AM Solar Inc.
3555 Marcola Rd.
Springfield, OR 97477
541.726.1091
www.amsolar.com
15 Minutes
Expion360
13.70V
14.60V
Rev.20181204