Always “On” UPS Systems Inc. 

 
 

 

GES V-Series – Single Phase Input, Single Phase 

Output 

Uninterruptible Power Supply 

 

 

 

GES-801V, GES-102V, GES-102VR, GES-152V, GES-152VR,  

GES-222V, GES-222VR 

Line Interactive (PWM): 800VA, 1kVA, 1.5kVA, 2.2kVA 

User Manual 

 

 

M0102_V_Series_801-222V_Manual V2.3 2012-06-12 

Summary of Contents for GES-102V

Page 1: ...Single Phase Input Single Phase Output Uninterruptible Power Supply GES 801V GES 102V GES 102VR GES 152V GES 152VR GES 222V GES 222VR Line Interactive PWM 800VA 1kVA 1 5kVA 2 2kVA User Manual M0102_V_...

Page 2: ...the skin and eyes It may be toxic CAUTION A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on or with the batt...

Page 3: ...ng with the UPS 1 Do not remove the UPS cover unless authorized by factory Removing the cover will void the warranty 2 The UPS can only be connected to a 2 pole 3 wire plug 3 Do not install the UPS in...

Page 4: ...Switching Off the UPS 8 4 3 Self Test 8 4 4 Silence the Alarm 8 4 5 Cold Start 8 4 6 Shutdown Mode 9 4 7 Green Function 9 5 AUDIBLE ALARM 10 5 1 Back Up Slow Alarm 10 5 2 Low Battery Rapid Alarm 10 5...

Page 5: ...es a low voltage state Also included with our UPS systems is a cyclic self testing function to verify both the operation of the UPS and the condition of the battery In addition the V Series UPS provid...

Page 6: ...M0102_V_Series_801 222V_Manual V2 3 2012 06 12 2 Figure 2 1 2 102VR Front Panel 7 8 9 1 5 6 10 Figure 2 1 1 Tower Front Panel Always O n I 1 2 3 4 5 6 Figure 2 1 3 152 222VR Front Panel I Line Mode B...

Page 7: ...5 LINE NORMAL indicator GREEN LED This LED illuminates when the line input voltage is normal RM version also flashes to indicate Backup mode 6 ON OFF TEST SILENCE button TEST SILENCE for GES 102VR Pre...

Page 8: ...Panel Left GES 801 102 152V Right GES 222V 2 3 8 7 5 6 Figure 2 2 2 Rear Panel GES 102VR OUTPUT REMOTE PORT BREAKER INPUT IN OUT 3 M0102_V_Series_801 222V_Manual V2 3 2012 06 12 4 8 7 2 6 Figure 2 2...

Page 9: ...ERNET INTRANET service 4 SITE WIRING FAULT INDICATOR RED LED Illuminates when the UPS is connected to an improperly wired AC power outlet Note This device is available on 110 VAC models only 5 SURGE P...

Page 10: ...perly without a computer interface connection 3 4 Connect to Utility Connect the AC input power connector Included to utility power 3 5 Charging the Battery The UPS charges its battery whenever the UP...

Page 11: ...e telephone connections and 10BaseT connectors This connection will require another length of cable This is optional UPS will work properly without this connection 3 8 Storage Conditions Store the UPS...

Page 12: ...ent push the On Off Test Silence Test Silence for GES 102VR Button for less than 1 second During the self test the UPS operates in back up mode During the self test the UPS briefly operates the loads...

Page 13: ...he computer interface can command the UPS to shutdown This is normally done to preserve battery capacity after the graceful shutdown of protected servers 4 7 Green Function In order to conserve batter...

Page 14: ...your dealer for service 6 SOFTWARE OPTIONS 6 1 UPSMON Software The UPSMON software uses the standard RS 232 interface to perform monitoring functions and then provides an orderly shutdown of a compute...

Page 15: ...ES 801V ES 102V and GES 152V G Pins for the GES 222V 1 Pin 8 5 and 6 2 are open collector outputs that must be pulled up to a common referenced supply no greater than 40VDC 2 The transistors are capab...

Page 16: ...S 232 RTS PIN 7 RS 232 DTR PIN 4 Contacts Normally Open Signal High Minimum 1 Second DB 9 Pin Configuration for the GES 801V 102V and 152V 1 2 3 4 5 6 7 8 9 3 6 7 8 4 2 9 5 Low Battery Mains Failure C...

Page 17: ...e battery plate and set the plate to the side For the 152 222VR The battery retainer plate should be visible Using a Phillips screwdriver remove the 3 screws holding the battery retainer plate on and...

Page 18: ...er Call for service Call service center to replace batteries UPS has no reaction while AC power is connected yet starts after pushing power on off switch Breaker at back panel open No AC input UPS AC...

Page 19: ...ion BATTERY Type Maintenance free Sealed Lead Acid Typical Recharge Time 4 hours to 90 of full capacity Protection Automatic self test discharge replace battery indicator Back up Time 10 30 minutes de...

Page 20: ...NT 6 87A 8 33A 12 5A FREQUENCY 50 60Hz Auto Detected WAVEFORM ON BATTERY PWM Pulse Width Modulated or Modifie POWER FACTOR 0 6 CREST FACTOR 3 1 on battery TRANSFER TIME 2 4 ms Typical OUTLETS 4 1 Surg...

Page 21: ...40 C 32 104 F HUMIDITY 0 90 Non Condensing AUDIBLE NOISE 40 dBA AT 1 METER FROM U SAFETY APPROVAL SAFETY cUL UL1778 CSA C22 2 EMI RFI FCC CLASS B SURGE TRANSIENT IEEE C62 41 CAT A PHYSICAL DATA WxDxH...

Page 22: ...mail sales alwaysonups com Website www alwaysonups com 11 2 QA Warranty Questions Always On UPS Systems Inc Bldg 1 150 Campion Road Kelowna BC Canada V1X 7S8 Phone 250 491 9777 Ext 209 Fax 250 491 977...