16
After finishing the above process, and check the protect switch of electric heat weather it is closed or not, if it is
closed and clear away the malfunction, and it gets into the normal sauna working, or repeat the above
process
When the system has above troubles, the buzzer will sound the voice “do” long times.
Three- Technical Specification:
Working Condition and characteristic
Rated Voltage
AC220V
Rated Frequency
50/60Hz
Rated Current
<=13A
Rated Power
2840W
>20M
Waterproof Level
IPX4
Dimensions
Control Box
Length*Width*High 195*65*42
Unit: mm
Remarks:
1. The waterless protection of steam generator is adopted by water level sensor.
2. The over-heater protection of steam generator is adopted by ceramic temperature sensor.
3. Difference steam generators have different rated current and rated power.
4. Without the permission of our technical department, please don’t enlarge the load power.
5. This product follows national standard
《
Safety of Household and similar electrical appliances
》
GB4706.1-2005
6. The installation of keyboard and electric box are attached in the appendix.
Three-Cautions:
In order prolong the lifetime of this product and ensure the safety of human being, please read these cautions
carefully before using this product.
1. User must strictly follow our provided circuit drawing and parameter to install the load.
2. The earth wire of control box must be well connected on the circuit.
3. User must use at least 3x2mm² power supply which meet the nation standards (GB), the socket of power supply
of the control box must be at least 20A, and fix it reliably.
4. User must add extra 20A or above national standard air switch or leakage switch, the leakage switch of control
box is only used as complement.
5. Please check and ensure the pipe of water intake, steam pipe, power control box, power supply of electric box
are in good condition, then turn on the power. (Attention: Ensure that water provided)
6. The inner hole of the steam pipe should be at least 15mm, strictly forbid to install valve on steam pipe.
Summary of Contents for LeonS90.20-V3 Blanco
Page 1: ...CABINA PARA DUCHA LeonS90 20 V3 Blanco...
Page 2: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ...18 18 18 18 18...
Page 8: ......
Page 9: ...31 33 33 31...
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 31: ...29 1...
Page 32: ...30 4 1 LCD 20 4 2 60 LCD 1 120 5 4 3 45 C LCD 25 C 60 C 5...
Page 34: ...32 5 4 2 5 4 3 3 87MHz 108MHz 0 15 5 5 5 1 3 15 1 5 1 4 2 2 1 2 2 1 2 E1...
Page 35: ...33 2 3 2 5 2 2 4 E3 3 10 30 AC220V 50 60Hz 13A 2840W 20M IPX4 195 65 42mm 1 2 3 4...
Page 36: ...34 5 GB4706 1 2005 6 1 2 3 3x2mm 20 4 20 5 6 15 7 8 9 10 5 10 1 4 60 30 11 12...
Page 37: ...35 1 2 3 1A 4 5 E3 1 5A 5A 2...
Page 38: ...36 1 2 3 4 1 2 3 4 1 2 3 1 2 3 1...
Page 39: ...37 1 2 3 4 5 1 2 3 4 5 6 7 1 2 3...
Page 40: ...38 1 AC220V 2 3 1 2 1...
Page 41: ......