Operation Verification
The following sections describe how to verify the correct functioning of the
Outdoor Units, Indoor Units, Ethernet connection and data connectivity.
Outdoor Unit Verification
To verify the correct operation of the Outdoor Unit, examine the LED
indicators located on the bottom panel of the outdoor unit.
The following tables list the provided LEDs and their associated
indications.
Table 4-4
:
Outdoor Unit LEDs
Name
Description
Functionality
W-LINK
Wireless Link Indicator
Blinking Green – Data received or transmitted on the
wireless link. Blinking rate is slower when there is less
wireless traffic.
DC Power
Self Test and Power
indication
Green – Power is available and self test passed.
Red – Self test failed. Firmware did not load
successfully.
ETH
Ethernet activity/
connectivity indication
Off –Ethernet connectivity is OK.
No traffic activity detected on the port.
Blinking Green –Ethernet connectivity is OK, with
traffic on the port.
Red – No Ethernet connectivity between the ondoor
and outdoor units.
SNR BAR
(SU-RA)
Received signal strength
Indication
10 green LEDs bar display indicating the level of the
received signal
Summary of Contents for BreezeACCESS VL 5.4
Page 1: ...BreezeACCESS VL System Manual January 2003 SW Version 1 0 Cat No 213409 ...
Page 12: ......
Page 30: ......
Page 60: ......
Page 124: ...BreezeACCESS VL System Manual B 2 ...
Page 126: ...BreezeACCESS VL System Manual C 2 ...
Page 137: ...Supported MIBs and Traps D 11 Air Interface Parameters ...
Page 147: ...Supported MIBs and Traps D 21 ...
Page 148: ......