INSTALLATION

This heater makes use of an industrial 

cylinder (9kg ALVA cylinder recommended) 

with a 5/8” BSP thread; horizontall exit valve. 

The Bullnose regulator supplied with the 

heater tightens to the left hand side 

(anti-clockwise). 

(Figure A)

If you have bought a new gas cylinder, the 

cylinder needs to be purged (emptied out), 

before it’s first use. If it is not purged of air, 

the heater will not work properly. 

This should happen at the gas filling station

 when you fill up the cylinder. 

Always check this with your gas supplier.

HEATER SET UP

1. 

Before removing this heater from the packaging, 

           read this manual in full and make sure that it is 

           what you want /need

2. 

Remove the heater from the packaging

3. 

Fold open the cylinder support base 

(Figure D)

 

           and secure with the 2 supplied screws.

4. 

Check if the nose cone is present, secure and

           in good condition. 

(Figure B)

5. 

The regulator goes directly into the cylinder valve. 

           Always make sure the regulator bottoms fully. 

           The use of any adaptors is illegal. 

6. 

Screw the regulator into the cylinder valve.                                                                                    

DO NOT use a tool to tighten the regulator; 

           it is to be hand-tightened only.

6.       Open the cylinder valve 1½ turns to the left 

          (anti-clockwise). 

(Figure C) 

7.       Push the control down for at least 10 seconds, 

          but DO NOT try to ignite the heater. 

          This will allow gas to flow through the heater, 

          making the leak test possible 

8.       DO THE LEAK TEST (please refer to 

page 4

)

9.       Place the cylinder in the heater cabinet by 

           securing the rear guard in place. 

(Figure D)  

 

Figure A

Figure B

Figure D

             

FLASHBACK (flames in the burner tube)

• 

If a flash back occurs (indicated by a roaring noise), immediately close the cylinder 

valve.

• 

Turn the heater OFF at the control knob.

• 

Disconnect the regulator and allow the heater to cool.

• 

Check for blockages in the venturi ports. Clean with compressed air, a small soft 

brush or pipe cleaners.

• 

If the problem persists in reuse, have the heater checked by a qualified technician.

CHANGING YOUR CYLINDER

Make sure you cylinder valve is closed (by turning it clockwise). Allow the heater to fully 

cool before replacing the cylinder. Open the rear of the heater to expose the cylinder.

(Figure H)

Remove and replace the cylinder. ALWAYS check that the regulator-sealing washer (nose 

cone) is intact and in place before reattaching the regulator to a cylinder. 

(Figure B - Page 3)

DO NOT attempt to remove the regulator while the heater is on or if the cylinder valve is 

not closed.

 

3

8

Figure C

Figure H

 

Summary of Contents for GH310S

Page 1: ...D FOR USE MUST NOT BE STORED IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE PRECAUTIONS Foamy bubbles indicate a leak Connection in heater assembly The leak test must be carried out in a or other sources of ignition 1 With the cylinder connected to the heater and the valve open press down the heater control knob the heater 2 Brush all the connections hose to valve hose to regulator regulator into ...

Page 2: ...se the cylinder valve The guarantee for the heater will be rendered void if the heater is serviced or repaired by any one other than an Alva appointed technician fault free The operator is responsible for the safety of all third parties while the heater is in use DO NOT place the heater near walls curtains or furniture while in use The heater should always face the centre of the room as indicated ...

Page 3: ...ls Is my heater faulty A It is normal for dust to settle on the panel When this happens the heater will not burn properly at first giving the appearance of a blue flame running on the panel This might happen when you first buy the unit after you have stored it There is nothing wrong with the heater Simply burn the dust off the panels by letting the heater run on Position 3 for between 5 and 15 min...

Page 4: ...ENANCE Always make sure the heater is OFF and cool with the cylinder valve closed before conducting any maintenance Your heater should be checked once a year by a If faults are suspected or detected stop using the heater and contact ALVA Clean the exterior and storage area of your heater when required to remove dust and prevent lint build up DO NOT use abrasive products to clean the heater these m...

Page 5: ...nly 6 Open the cylinder valve 1 turns to the left anti clockwise Figure C 7 Push the control down for at least 10 seconds but DO NOT try to ignite the heater This will allow gas to flow through the heater making the leak test possible 8 DO THE LEAK TEST please refer to page 4 9 Place the cylinder in the heater cabinet by securing the rear guard in place Figure D Figure A Figure B Figure D FLASHBAC...

Page 6: ... heater assembly USING YOUR HEATER This heater can be regulated to three different heat selections 1 2 and 3 1 Open the cylinder valve by turning the cylinder valve to the left 2 Press the control knob down at the OFF position and turn to position 1 Hold the control knob for 10 15 seconds 3 While holding it down slowly press the red ignition button to ignite The heater should make a click sound an...