Alva GH310S Assembly & Operating Instructions Download Page 1

 

INDOOR GAS HEATER (GH310S)

Assembly and operating instructions

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE 

THIS IS A LOW PRESSURE APPLIANCE 

TO BE USED ONLY WITH A 2.8kPa 

 SANS 1237 APPROVED REGULATOR

(REGULATOR FITTED AND SUPPLIED)

FOR YOUR OWN SAFETY, 

PLEASE READ THIS MANUAL 

CAREFULLY AND ALWAYS

OPERATE THIS PRODUCT ACCORDING

TO THE INSTRUCTIONS

IT IS ILLEGAL AND DANGEROUS 

TO CHANGE OR MODIFY ANY PART 

OF THIS APPLIANCE   

  

     WARNING

• TURN OFF GAS SUPPLY AT CYLINDER

• EXTINGUISH ALL NAKED FLAMES. 

   DO NOT OPERATE ANY ELECTRICAL 

   APPLIANCES.

• VENTILATE THE AREA

• CHECK FOR LEAKS AS DETAILED 

   IN THIS MANUAL

• IF ODOUR PERSISTS, CONTACT YOUR 

  DEALER OR GAS SUPPLIER IMMEDIATELY . 

FOR YOUR SAFETY

IF YOU SMELL GAS:

•  LEAK TEST ALL CONNECTIONS AFTER 

    EACH TANK REFILL

•  NEVER CHECK FOR LEAKS WITH A MATCH 

    OR OPEN FLAME

•  DO NOT STORE OR USE GASOLINE, 

    OR OTHER FLAMMABLE VAPOURS 

    AND LIQUIDS IN THE VICINITY OF THIS 

    OR ANY OTHER APPLIANCE

•  ANY LP GAS CYLINDER NOT CONNECTED

    FOR USE MUST NOT BE STORED IN THE 

    VICINITY OF THIS OR ANY OTHER APPLIANCE

PRECAUTIONS

Foamy bubbles 

indicate a leak

Connection 

in heater

assembly 

The leak test must be carried out in a 

or other sources of ignition.

1)  With the cylinder connected to the    

     heater and the valve open, press down  

     the heater control knob. 

     the heater.

2) Brush all the connections (hose to valve,  

     hose to regulator, regulator into 

     cylinder) with a solution of equal parts 

     soap and water (make sure it’s foamy).

3) A stream of bubbles forming indicates a 

     gas leak.

4) If bubbles appear, turn the cylinder 

     valve OFF (clockwise) and disconnect 

     the regulator from the gas cylinder.

5) Tighten the connection and retry the 

     leak test.

6) If you are unsure or if you cannot 

     tighten the connection, place the 

     cylinder outside in a cool,  

     well-ventilated area and contact Alva 

     on 086 100 ALVA (2582)

7) A leak between the regulator and  

     which is very dangerous and can lead to  

     extensive injury or even death.

LEAK TEST

Distributed and serviced by ALVA Marketing ( Pty) Ltd, P.O. Box 30014, Tokai, 7966

 Tel: 082 100 ALVA (2582)•  E-mail: [email protected] • www.alva.co.za

         @StingrayGroupSA •       www.facebook.com/AlvaGas

       

Summary of Contents for GH310S

Page 1: ...D FOR USE MUST NOT BE STORED IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE PRECAUTIONS Foamy bubbles indicate a leak Connection in heater assembly The leak test must be carried out in a or other sources of ignition 1 With the cylinder connected to the heater and the valve open press down the heater control knob the heater 2 Brush all the connections hose to valve hose to regulator regulator into ...

Page 2: ...se the cylinder valve The guarantee for the heater will be rendered void if the heater is serviced or repaired by any one other than an Alva appointed technician fault free The operator is responsible for the safety of all third parties while the heater is in use DO NOT place the heater near walls curtains or furniture while in use The heater should always face the centre of the room as indicated ...

Page 3: ...ls Is my heater faulty A It is normal for dust to settle on the panel When this happens the heater will not burn properly at first giving the appearance of a blue flame running on the panel This might happen when you first buy the unit after you have stored it There is nothing wrong with the heater Simply burn the dust off the panels by letting the heater run on Position 3 for between 5 and 15 min...

Page 4: ...ENANCE Always make sure the heater is OFF and cool with the cylinder valve closed before conducting any maintenance Your heater should be checked once a year by a If faults are suspected or detected stop using the heater and contact ALVA Clean the exterior and storage area of your heater when required to remove dust and prevent lint build up DO NOT use abrasive products to clean the heater these m...

Page 5: ...nly 6 Open the cylinder valve 1 turns to the left anti clockwise Figure C 7 Push the control down for at least 10 seconds but DO NOT try to ignite the heater This will allow gas to flow through the heater making the leak test possible 8 DO THE LEAK TEST please refer to page 4 9 Place the cylinder in the heater cabinet by securing the rear guard in place Figure D Figure A Figure B Figure D FLASHBAC...

Page 6: ... heater assembly USING YOUR HEATER This heater can be regulated to three different heat selections 1 2 and 3 1 Open the cylinder valve by turning the cylinder valve to the left 2 Press the control knob down at the OFF position and turn to position 1 Hold the control knob for 10 15 seconds 3 While holding it down slowly press the red ignition button to ignite The heater should make a click sound an...