3 Holid
ay
Holid
ay temperatu
res settings
1 CH holid
ay set point
Set CH temperatu
re used when Holid
ay mode acti
ve
2 DHW holid
ay set point
Set DHW temperatu
re used during holid
ay mode
4 Maintenance
Set maintenance
related info
1 Se
rvice information
Used
to displ
ay se
rvice company phone number or
ente
red info
2 Se
rvice due date
Show next se
rvice due date . When date expi
re a MSG
is shown on lower pa
rt of main sc
reen asking for service
5 Settings
Boiler option settings
1 Select Language
Allow selection of a di
ffe
rent language
English
Select for English
Italian
Select for Italian
German
Select for German
Russian
Select for Russian
2 Select units
Allow selection of di
ffe
rent unit
Fah
renheit
Select for
Fah
renheit
Celsius
Select for Celsius
3 Set date
Allow
RT
C date setting
4 Set time
Allow
RT
C time set. When selected a sc
reen asking for
time format 24/12 Hours is opened. When selected ap- pr
opriate format sc
reens jump
to time entering sc
reen
24 hours
Select for 24 hours clock
12 hours
Select for 12 hours clock
5 Res
to
re fac
to
ry data
Pr
essing OK all the user settings will be
res
to
red
to the
original fac
to
ry default settings. See 1)
6 Chimn
ey sweeper
Manual mode. Hitting OK will fo
rce boiler
to operate at
% of power
Timeout 15 minutes. While test in p
rog
ress n
avigating
th
rough other menus is allowed.
7 Diagnostics
Will displ
ay boiler usage information and er
rors
1 Boiler information
Boiler information
"1 CH
request
2 DHW demand
3 Firing rate
4 Flame ionization cur
rent
5 Boiler set point
6 Boiler supply tempera- tu
re
7 Return temperatu
re
8 Flue temperatu
re
9 Outdoor temperatu
re
10 DHW s
torage temperatu
re
11 Boiler fan speed
12 CH ignitions
13 CH runtime
14 DHW ignitions
15 DHW runtime
16 System p
ressu
re
17 Heat E
xchanger
Temp.
18 0-10V input
19
Ta
rget powe
r"
Will displ
ay the information shown in SUBMENU 2
When the line has a * at the end of the line means that hitting
OK
when
the
line
is
highlighted
will
open
a
graph
that shows the latest 120
variable
values s
to
red
ev
er
y
12 minutes (24 hour his
to
ry)