ПРИВОДЫ TARGO (СЕРИЯ TR)
|
ПРИВОДИ TARGO (СЕРІЯ TR)
|
TARGO DRIVES (TR SERIES)
48
OPERATION
8.
OPERATION
When operating:
• the product shall not be used by children or persons with limited physical, sensory or mental
abilities, nor by persons with insufficient experience and knowledge.
• Do not touch a moving door or moving parts.
• Before starting movement of the door make sure that no people, animals, vehicles or objects
are located in the operational (danger) area of the door. Monitor the door movement. Passage
of people and vehicles through the door opening whilst the door is moving is prohibited.
• Children should be under the supervision to prevent playing with the device.
• Be careful when using the manual release facility to disengage the door’s drive, as an open
door can fall quickly due to slack or broken springs, or door imbalance.
• Regularly check the drive system check cables, springs and mounting hardware for the signs of
wear, damage or imbalance. It is prohibited to use a door which requires repair or adjustment,
as the mounting defect or incorrect balance of the door may result in injury or drive failure.
• If the power cord is damaged, it must be replaced by the manufacturer, service provider or
similar qualified personnel to avoid danger.
Perform scheduled maintenance at least once every six months. Scheduled maintenance
shall include:
• checking the drive and door elements (key, cams, electrical cables, door components, etc.),
paying attention to the oxidisation of the components. Replacing all parts and units with an
unacceptable degree of wear. Please use the original spare parts.
• Check that no grease leaks out of the drive.
• Checking the accuracy of the door stops in their final positions. If necessary, reprogramme the
final positions.
• Cleaning the external surfaces of the drive. Performing the cleaning with the help of a soft
moist cloth. The use of the following for cleaning is forbidden: water jets, high pressure
cleaners, acids and alkali.
• Performing the check according to the instructions in section ‘7. Testing and commissioning’.
The service life is 8 years, but not more than 50,000 cycles.
Y
The company does not perform direct control of the mounting of the drive and automation
devices, their maintenance and operation, and cannot be responsible for the safety of the
drive mounting, operation and maintenance.
9.
TROUBLESHOOTING
FAULT
POSSIBLE REASON
RECOMMENDATIONS
Drive does not work
No supply voltage, poorly clamped
wires on terminals
Check the supply voltage. Clamp wires
on terminals
Drive does not work
The drive is unlocked or the emergency
manual control chain is activated
Lock the drive. Check the operation of
the emergency manual control chain
The door moves in the wrong
direction
Wrong electrical connections
Check the electrical connections of
the drive
The door stops, but the drive
continues to operate
An obstruction is in the path of door
movement, wrong drive adjustment
Eliminate the obstruction in the path
of door movement, check adjustments
of the final positions
The door does not stop at the
required final positions
The final positions are not adjusted or
have changed
Adjust the final positions
The drive suddenly stops
during the door movement
Thermal protection of the drive motor
has tripped
Allow the drive motor to cool down