CONNECTION AND OPERATIONAL MANUAL. CONTROL UNIT CUL01
6
6
PACKAGED ELECTRONIC CIRCUIT
Table
2. Circuit elements list
Element
Description
U8
Safety device T6.3А
ATTENTION
: Use safety devices filled with glass sand!
U9
U10
U11
Transformer
U12
2А safety device
REL1
Relay
REL2
LED1
The
LED
which signals the valve’s operational status.
It is on if power voltage is supplied to the valve
J1
Jumper for selection of safety sensor type:
PNP
or
NPN
(transistor output)
J2
Control button
2
adapter (
pic
. 1)
J3
Network adapter (
pic
. 3)
J4
Protection grounding adapter
J7
Jumper adapter depending on the supply voltage.
If supply voltage is 400 V, the jumper must be installed as in
pic
. 2
J8
Line circuit breaker
1
adapters (
pic
. 1,
pic
. 2).
The plug of 015 3P + N + E 16A / 6h type is used for network connection.
The socket must be of the same type for the plug using it
J9
J10
The adapter of a hydraulic unit valve (
pic
. 5) and sectional doors position
sensor (
pic
. 6). Security sensor supply voltage is 24 V DC. If the security sensor
has signaled (sectional doors are closed), the hydraulic unit electric motor
must be turned off and the platform must be blocked
J11
The adapter of a hydraulic unit electric motor (
pic
. 4) and stop-motion
sensor (
NC
)
J12
LED1
jumper. The
LED
will be on if the jumper is installed.
If the jumper is removed, the
LED
is off.
Y
If security sensors are not plugged in (J10 and J11 adapters), jumpers must be installed
(
pic
. 2). If a security sensor is plugged in, remove the jumper.