background image

CONNECTION AND OPERATIONAL MANUAL. CONTROL UNIT CUL01

6

6

PACKAGED ELECTRONIC CIRCUIT

Table

 2. Circuit elements list

Element

Description

U8

Safety device T6.3А

ATTENTION

: Use safety devices filled with glass sand!

U9
U10
U11

Transformer

U12

2А safety device

REL1

Relay

REL2

LED1

The 

LED

 which signals the valve’s operational status.  

It is on if power voltage is supplied to the valve

J1

Jumper for selection of safety sensor type: 

PNP

 or 

NPN

 (transistor output)

J2

Control button

 2

 adapter (

pic

. 1)

J3

Network adapter (

pic

. 3)

J4

Protection grounding adapter

J7

Jumper adapter depending on the supply voltage.  

If supply voltage is 400 V, the jumper must be installed as in 

pic

. 2

J8

Line circuit breaker 

1

 adapters (

pic

. 1, 

pic

. 2).  

The plug of 015 3P + N + E 16A / 6h type is used for network connection.  

The socket must be of the same type for the plug using it

J9

J10

The adapter of a hydraulic unit valve (

pic

. 5) and sectional doors position 

sensor (

pic

. 6). Security sensor supply voltage is 24 V DC. If the security sensor 

has signaled (sectional doors are closed), the hydraulic unit electric motor 

must be turned off and the platform must be blocked

J11

The adapter of a hydraulic unit electric motor (

pic

. 4) and stop-motion 

sensor (

NC

)

J12

LED1

 jumper. The 

LED

 will be on if the jumper is installed.  

If the jumper is removed, the 

LED

 is off.

 

Y

If security sensors are not plugged in (J10 and J11 adapters), jumpers must be installed 

(

pic

. 2). If a security sensor is plugged in, remove the jumper.

Summary of Contents for CUL01

Page 1: ...CONNECTION AND OPERATIONAL MANUAL Control unit CUL01 English 2020 www alutech group com ...

Page 2: ......

Page 3: ... that you have made the right choice ALUTECH Group of companies has the right to change and complement item construction and this document without warning CONTENTS 1 General provisions and safety measures 3 2 Item description 4 3 Specifications 4 4 Packaged electronic circuit 5 5 Operation 8 6 Storage tranportation and utilisation 8 7 Warranty 8 8 Certificate of comissioning 9 9 Warranty repair 10...

Page 4: ......

Page 5: ...wards so as to prevent water from filling its enclosure Turn the power off when carrying out any works installation repair service cleaning etc and connecting the item If the switching unit is out of sight attach the notice plate Do not turn on People are working and take measures to avoid unsanctioned restoring of the supply If the power cable power cord is damaged it must be replaced by the manu...

Page 6: ...contents of this manual cannot be used as grounds for legal challenges 2 ITEM DESCRIPTION The control unit is used for SL dock leveller with swing lip with 1 valve hydraulic unit There is a line circuit breaker 1 and control button 2 on the cover of the control unit body pic 1 The dimensions for mounting are also shown on pic 1 in millimetres 1 2 190 280 254 180 Pic 1 CUL01 control unit 3 SPECIFIC...

Page 7: ...as a packaged electronic circuit installed to which electrical devices are connected pic 2 See the circuit elements list in Table 2 J11 J4 J3 J9 HPT IN W V U L1 L2 L3 N PE PE HPT OUT L1 L2 L3 J8 MOTOR REL1 U8 U9 U10 J7 230V 400V U11 U12 REL2 J10 24V Vent Sens GND GND J1 NPN PNP J12 LED1 J2 2A T 3 6 3A T Pic 2 Packaged electronic circuit ...

Page 8: ...e jumper must be installed as in pic 2 J8 Line circuit breaker 1 adapters pic 1 pic 2 The plug of 015 3P N E 16A 6h type is used for network connection The socket must be of the same type for the plug using it J9 J10 The adapter of a hydraulic unit valve pic 5 and sectional doors position sensor pic 6 Security sensor supply voltage is 24 V DC If the security sensor has signaled sectional doors are...

Page 9: ...J11 J4 W V U PE PE M 3 Pic 4 Electric motor connection Y If the platform does not move travel direction does not coincide with the required one when the control button 2 is pushed two electric motor phase wires are to change their positions J10 24V Vent Sens GND GND J10 24V Vent Sens GND GND BN BK BU BN коричневый BK черный BU синий Pic 5 Valve connection Pic 6 Security sensor connection sectional...

Page 10: ... force in the country of the customer The item does not contain precious metals and substances dangerous for life health and environment Y The package must be utilised in accordance with existing legislation 7 WARRANTY The item works well if it is stored transported adjusted and run according to the existing rules if installation and technical service are provided by the organisation specialising ...

Page 11: ...e for installation signature print name Consumer Applicant have checked the completeness of the set is aquianted and agrees with warranty conditions and terms has no complaints about the item design The item is installed and adjusted in accordance with the specified requirements and is suitable for operation Safety and operational instruction has been conducted Applicant consumer name address and ...

Page 12: ...ganisation List of repair works Date of repair LS Responsible for repair signature ________________________________________________________ print name Repair organisation List of repair works Date of repair LS Responsible for repair signature _________________________________________________ print name ...

Page 13: ...CONNECTION AND OPERATIONAL MANUAL CONTROL UNIT CUL01 11 11 COMMENTS COMMENTS ...

Page 14: ......

Page 15: ......

Page 16: ...Art R7090126 03 2018 10 Selitskogo str 220075 Minsk Republic of Belarus Tel 375 17 330 11 00 Fax 375 17 330 11 01 www alutech group com ...

Reviews: