Alula RE607 Quick Start Manual Download Page 3

Magnet Gap Specifications

Non-Ferromagnetic Surface (e.g. 

Wood, Vinyl, etc.)

Nominal Mounting Distance

X Axis - Make

Break

Y Axis - Make

Break

Z Axis - Make

Break

2.70 inches (6.86 cm)
2.80 inches (7.11 cm)
2.85 inches (7.24 cm)
3.50 inches (8.89 cm)
3.55 inches (9.02 cm)
3.27 inches (8.31 cm)
3.33 inches (8.46 cm)

Ferromagnetic Surface (e.g. 

Iron, Nickel, etc.)

Nominal Mounting Distance

X Axis - Make

Break

Y Axis - Make

Break

Z Axis - Make

Break

1.90 inches (4.83 cm)
2.00 inches (5.08 cm)
2.05 inches (5.21 cm)
2.50 inches (6.35 cm)
3.00 inches (7.62 cm)
2.32 inches (5.89 cm)
2.37 inches (6.02 cm)

*Sensitivity can be adjusted by moving the magnet in 

the closed position farther away from the sensor.

Z Axis

Y Axis

X Axis

X Axis

Summary of Contents for RE607

Page 1: ...racter serial number on the interactive service provider s web portal External contacts can be added on the interactive service provider s web portal Install by first attaching the mounting plate and magnet to a door window or fence using screws provided or cable ties not provided Make sure to align the alignment marks on the sensor and magnet when mounting Finish by latching the sensor to the mou...

Page 2: ... reprogram external inputs set both externals to the desired non alarm state and restart remove and reinstall battery the device 3 times while holding the tamper switch Thinned area for external contact wires Removal Tamper is implemented by screwing the provided screw with rubber washer through the removal tamper screw hole in the base and into the mounting surface Remove the battery for access t...

Page 3: ...es 9 02 cm 3 27 inches 8 31 cm 3 33 inches 8 46 cm Ferromagnetic Surface e g Iron Nickel etc Nominal Mounting Distance X Axis Make Break Y Axis Make Break Z Axis Make Break 1 90 inches 4 83 cm 2 00 inches 5 08 cm 2 05 inches 5 21 cm 2 50 inches 6 35 cm 3 00 inches 7 62 cm 2 32 inches 5 89 cm 2 37 inches 6 02 cm Sensitivity can be adjusted by moving the magnet in the closed position farther away fr...

Page 4: ...subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference that may be received including interference that may cause undesired operation Changes or modifications not expressly approved by Alula could void the user s authority to operate this equipment FCC ID U5X RE607 Specifications subject to change without notice Physical ...

Reviews: