Non-Ferromagnetic Surface

Nominal Mounting Distance

X Axis - Make

Break

Y Axis - Make

Break

Z Axis - Make

Break

0.75 inches (2.0 cm)
0.90 inches (2.3 cm) 
0.95 inches (2.5 cm)
1.70 inches (4.3 cm)
1.75 inches (4.5 cm)
1.10 inches (2.8 cm)
1.15 inches (3.0 cm)

Ferromagnetic Surface (Using RE033 Mount)

Nominal Mounting Distance

X Axis - Make

Break

Y Axis - Make

Break

Z Axis - Make

Break

0.50 inches (1.2 cm)
0.55 inches (1.4 cm)
0.60 inches (1.5 cm)
1.50 inches (3.8 cm)
1.55 inches (4.0 cm) 

0.70 inches (1.8 cm)
0.75 inches (2.0 cm)

Magnet Gap Specifications

Z Axis

X Axis

Y Axis

Summary of Contents for RE222 NanoMax

Page 1: ...ent sequence needed by Honeywell panels Sensor trips should be spaced by two seconds when enrolling Install by removing the adhesive paper and adhering the NanoMax and magnet on a door or window Make sure to align the alignment marks on the NanoMax and magnet when mounting Alternatively NanoMax can be used with an external contact instead of using the reed switch External Contact not evaluated by ...

Page 2: ... performance is optimized when mounted near the top of the door in a vertical orientation OK BEST WRONG Accessories MetalMax NanoMax Mounts RE033 16 can be used for better performance on metal and narrow mounting situations Improves wireless performance by moving the internal antenna away from metal surfaces Provides an alternate mounting orientation for narrow installs Increases magnet gap distan...

Page 3: ...inches 4 3 cm 1 75 inches 4 5 cm 1 10 inches 2 8 cm 1 15 inches 3 0 cm Ferromagnetic Surface Using RE033 Mount Nominal Mounting Distance X Axis Make Break Y Axis Make Break Z Axis Make Break 0 50 inches 1 2 cm 0 55 inches 1 4 cm 0 60 inches 1 5 cm 1 50 inches 3 8 cm 1 55 inches 4 0 cm 0 70 inches 1 8 cm 0 75 inches 2 0 cm Magnet Gap Specifications Z Axis X Axis Y Axis ...

Page 4: ...n of the device Le présent appareil est conforme aux cnr d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 L appareil ne doit pas produire de brouillage et 2 L utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement IC 8310A...