Alula BAT LTE Product Manual Download Page 13

13

*48

7,7 

Enables Contact ID

*47

Enter 1

ECP Bus Programming:  

ONLY NEEDED IF USING ECP TO SEND SIGNALS AND NOT TIP/RING
Vista Programming for Communications - GSM Emulation:

Sec

BAT LTE as Sole 
Communicator

BAT LTE in use 

with another 

Communication 

Device for Failover

For Dual 

Reporting

Code Summarization

*29

Enter 1

Enter 1

Enter 1

This enables GSM. The 

BAT LTE Emulates a GSM.

*42

N/A

Enter Central 

Station Receiver 

Number

Enter Central 

Station Receiver 

Number

Secondary Phone Number

*43

Enter Account 

Number

Enter Account 

Number

Enter Account 

Number

This is the central station 

account number

*49

Enter 5

Please refer to 

panel manual for 

your particular 

application 

requirements

Please refer to 

panel manual for 

your particular 

application 

requirements

Dual Reporting; Setting 

to 5 sends all reporting 

to both primary and 

secondary.

*54

Enter 0

Enter 2

Enter 0

The time it takes for the 

communicator to switch 

from primary to secondary.

*55

Enter 1

Enter 1

Enter 1 (BAT 

LTE is Primary 

Communicator)

Setting to 1 gives signal 

priority to GSM (BAT LTE).

*65

Enter 1

Enter 1 till beep

Enter 1

Report Code for Openings.

*66

Enter 1, 1

Enter 1, 1 till beep`

Enter 1, 1

Report Code for Arming in 

Away and Stay.

*193

Enter 1, 0

Enter 1, 0

Enter 1, 0

1 turns on/off keypad 

address. 0 sets sound to 

beep.

*48

7,7 

Enables Contact ID

See Supported Panels section on pages 18-19 to verify your panel’s revision number and GSM emulation programming.

Summary of Contents for BAT LTE

Page 1: ...PRODUCT MANUAL BAT LTE SKU IPD BAT LTE Universal Internet Cellular 4G LTE Alarm Communicator ...

Page 2: ...2 Technical Support Information For Technical Support call toll free 888 88 ALULA alula net www alarmdealer com setup alarmdealer com Mobile Friendly Alula 1402 Heggen St Hudson WI 54016 ...

Page 3: ...Wiring and Programming 8 DSC PC Link Connection 9 DSC Programming Charts 10 11 Honeywell Vista Panel Wiring and Programming 12 Honeywell Vista Programming Charts 13 GE Panel Wiring and Programming 14 GE Panel Programming Chart 14 Generic Alarm Panel Wiring and Programming 15 17 Supported Panels Charts 18 19 Specifications 19 ...

Page 4: ...n 2 Enter 13 for Contact ID Programming on Vista BAT LTE as Sole Communicator 41 Enter Phone Number 43 Enter Account Number 193 Enter 1 0 Enable to turn on Address 20 48 Enter 7 7 for Contact ID Programming on DSC Section BAT LTE as Sole Communicator 301 Enter Phone Number 310 Enter Account Number 350 Enter 03 for Contact ID QUICK REFERENCE ...

Page 5: ...interfaces Refer to wiring diagram for your specific panel Panel side of the virtual keypad connection will use various labels such as Data in Data out YEL GRN or Data This connects to the G RX Y TX connections on the Product Before installing any alarm communicator you must first be a registered dealer with Alula and you must also register your device using our Dealer Portal AlarmDealer com Pleas...

Page 6: ...is is used for Interactive Services Terminal G In connects to the Green Rx connector on the Panel This is used for Interactive Services Program the panel to communicate alarm signals Enter the Central Station phone number and account number using the alarm panel keypad Make sure the panel is set to send in Contact ID mode Please reference the alarm panel s guide for detailed panel programming info...

Page 7: ...he unit will be recorded on the customer s event log within the AlarmDealer com portal Please reference Alula s AlarmDealer com Dealer User Guide for detailed information Wiring Programming for Popular Panels The following pages are organized by Alarm Panel type Wiring and programming instructions are given for Digital Security Control DSC Alarm Panels Ademco Honeywell Vista Alarm Panels GE Networ...

Page 8: ...anels section on page 18 Perform the TELCO Programming if Tip Ring is being used TELCO Programming General Concept Programming on DSC BAT LTE as Sole Communicator Section As Sole Communicator Code Summarization 301 Enter a Receiver Number 310 Enter Account Number 350 Enter 03 to send Contact ID Panel default is 04 SIA Note Ensure All Report Codes are in and signals can be sent ...

Page 9: ...DSC PC Link connection PC Link connection should only be used when the communicator is being installed as a back up or uploading downloading using DLS V Remote downloader functionality requires Alula s uDownloader software ...

Page 10: ...AAF CAAF has to be set for the panel to send signals to the PC Link 302 N A N A Set Central Station Receiver Second telephone number goes here 303 N A Set Central Station Receiver Set Central Station Receiver This section is the telephone backup of section 301 350 Set 04 04 Set 04 03 for Contact ID 04 for SIA FSK Set 04 03 for Contact ID 04 for SAI FSK Format sent as either contact ID 03 or SIA FS...

Page 11: ...r telephone 1 option 1 telephone 2 option 2 and alternate communications option 5 380 Enable Option 1 Enable Option 1 5 Enable Option 1 5 Option 1 turns on off communications Option 5 turns on off 3rd phone number 381 Disable Option 3 Enable Option 5 Disable Option 3 Enable Option 5 6 Disable Option 3 Enable Option 5 6 Option 3 turns on off code reporting Options 5 6 turns on off communication wit...

Page 12: ...gnals then you can perform ecp bus programming Otherwise ALWAYS use TELCO programming TELCO Programming Programming on Vista BAT LTE as Sole Communicator Section BAT LTE as Sole Communicator Code Summarization 41 Enter Phone Number 43 Enter Account Number 49 Enter 5 For All Communications to BAT LTE 54 Enter 0 No Delay Between Communicators 55 Enter 0 Phone Line Communicates First 65 66 Enter 1 ti...

Page 13: ...ease refer to panel manual for your particular application requirements Please refer to panel manual for your particular application requirements Dual Reporting Setting to 5 sends all reporting to both primary and secondary 54 Enter 0 Enter 2 Enter 0 The time it takes for the communicator to switch from primary to secondary 55 Enter 1 Enter 1 Enter 1 BAT LTE is Primary Communicator Setting to 1 gi...

Page 14: ...s with Tip Ring Keyswitch alternative programming see Page 17 TELCO Programming General Concept Programming on GE NetworX Section BAT LTE as Sole Communicator Code Summarization Device 0 Location 0 Enter the Phone Number Device 0 Location 1 Enter Account Number Device 0 Location 2 Enter 13 Contact ID ...

Page 15: ...and Programming Generic Alarm Panel Programming Program the panel Phone Number into the panel Program the Customer Account Number into the panel Program Reporting codes into the panel Program panel to transmit in 10 digit CID format ...

Page 16: ...needed A programmable output on the alarm panel will be used to signal to the Product Y Tx terminal that the panel has entered Arm Disarmed State The Z1 output on the Product will be used as a key switch connecting to a zone terminal on the alarm panel Panel zone resistor placed on Terminal 3 to 5 to determine correct arm and disarm state ...

Page 17: ... the alarm panel installation manual for details on your specific installation Ademco Honeywell Vista General Concept 56 program zone as type 77 80 Menu LED Outs Program 17 and 18 zone type 78 and 79 DSC PowerSeries General Concept Program zone as 22 PGM Output 6 DSC Alexor General Concept Wiring Y Tx I 01 Terminal 13 I 02 6 2k ohms resistor from positive Y Tx Programming Section 009 05 22 Section...

Page 18: ...2 Vista 15CN 2 6 Vista 15P 2 6 Vista 15PCN 2 6 Vista 15PSIA 4 0 Vista 20P 2 6 Vista 20PCN 2 6 Vista 20PI 5 Vista 20PS 2 6 Vista 20PSIA 4 0 Vista 21IP 1 0 Vista 21IPSIA 1 0 Vista 32FB 1 0 First Alert FA130 2 6 First Alert FA148 2 6 First Alert FA168 2 6 ADT Safewatch Pro 3000 3000EN 2 6 DSC Digital Security Control Panel Revision Digital Dialer Full Interactive GSM Emulator PC5010 Any PC1616 4 13 P...

Page 19: ...ported as long as it provides Tip Ring and transmits Contact ID If the panel has the ability to use a Dedicated Open Zone that acts as a Keyswitch you can Arm Disarm from the Website or Mobile Phone Specifications Radio Frequencies LTE 1x 1900MHz 1700MHz 700MHz Power Externally provided 12v DC Typical Current 130 mA Max Current 180 mA Environmental Temperature Range 30 to 70 C 22 to 158 F Humidity...

Page 20: ...ula 1402 Heggen St Hudson WI 54016 888 88 ALULA All product and company names are trademarks or registered trademarks of their respective holders Use of them does not imply any affiliation with or endorsement by them ...

Reviews: