ALTUNA
AB32
26
EN
Meanings of Shears Alarms
Alarm Content
The Mainboard’s LED
Flashes for Several
Times
The Mainboard’s BUZ
Rings ForSeveral
Times
Display Fault
of the
LED
No Fault
0
0
E00
Anti-hand Cutting Protection
1
1
E01
Current Sensor Error
2
6
E02
MOS Tube Damage
3
6
E03
Hall Fault/Blade Breaking
4
3
E04
Peak Overcurrent/Average
Current Protection
5
5
E05
Blocked Opening/Blocked Rotor
6
3
E06
Default Phase
7
4
E07
Undervoltage/Overvoltage
8
1
E08
MOS/Chip Over-temperature
9
6
E09
PWM Communication Failure/
Shears Bit Voltage Error
10
2
E10
Shears Bit Type Error
10
7
E10
EEPROM Error
11
6
E11
Phase Detection Failure
12
4
E12
Programming Error
13
6
E13
> Historical Pruning Times
14
5
E14
> Maintenance Pruning Times
15
5
E15
The Number of Batteries in the
Shears Bit and Battery Pack is
Different
16
9
E16
The Mainboard Fails to Commu-
nicate with the Battery Pack
17
10
E17
FAIL INDICATIONS
|
In case of any fault, please handle it according to the prompt code on the display
screen.
Fault prompt on the display screen:
When using this product, if the following code appears on the screen, repair or handle accor-
ding to the corresponding fault prompt.
E14: defined, unexecuted protection;
E15: defined, only unexecuted protection is reminded and the display board beeps five times
per minute;