background image

 

- 2 - 

VertiLine33DV / 63DV Series Installation Guide

Overview:

Altronix VertiLine Rack Mount Power Supplies provide sixteen (16) filtered and electronically regulated power 

outputs in a space saving 1U EIA 19”    rack mount chassis. The units are available with either 12VDC or 24VDC 

power outputs. VertiLine Rack Mount Power Supplies are also available with eight (8) outputs.

Specifica tions:

Agency Listing:

•  CE European Conformity.

Input:

•  220VAC 50/60Hz.

Output:

•  Filtered and electronically regulated outputs.

VertiLine33DV, VertiLine33TDV:

•  Sixteen (16) PTC protected 12VDC power outputs.

VertiLine63DV, VertiLine63TDV:

•  Sixteen (16) PTC protected 24VDC power outputs.

Features:

•  Sixteen (16) power LED indicators.

•  Illuminated master power disconnect 

  circuit breaker with manual reset.

•  IEC 320 - 3-wire grounded line cord (detachable).

•  Removable terminal blocks with locking 

  screw flange.

Mechanical:

•  Units can be rack, wall or shelf mounted.

•  Modular 1U standard EIA 19” rack mount chassis.

•  Enclosure Dimensions (H x W x D approx.):

  1.625” x 19.125” x 8.5” 

  (41.3mm x 486mm x 216mm).

Sixteen (16) Output Rack Mount Configuration Reference Chart:

Altronix

Model Number

Output 

Voltage

Total Output

Current 

(Power)

Number 

of 

Outputs

Output 

Protection

Current (max. 

per output)

220VAC 

50/60 Hz

Input Current

VertiLine33DV

12VDC

8A

16

PTC

2.5A

0.75A

VertiLine33TDV

12VDC

16A

16

PTC

2.5A

1.5A

VertiLine63DV

24VDC

8A

16

PTC

2.5A

1.5A

VertilLine63TDV

24VDC

16A

16

PTC

2.5A

3A

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or mois-
ture. This installation should be made by qualified service personnel and should conform to 
the National Electrical Code and all local codes.

Summary of Contents for VertiLine 33DV Series

Page 1: ...ed outputs VertiLine63TDV 24VDC 16A Sixteen 16 PTC protected outputs VertiLine 33DV 63DV Series Rack Mount Power Supplies Models Include Rev 090810 More than just power TM Installing Company ________________ Service Rep Name ___________________________________ Address ______________________________________________ Phone ___________________ Installation Guide ...

Page 2: ...ircuit breaker with manual reset IEC 320 3 wire grounded line cord detachable Removable terminal blocks with locking screw flange Mechanical Units can be rack wall or shelf mounted Modular 1U standard EIA 19 rack mount chassis Enclosure Dimensions H x W x D approx 1 625 x 19 125 x 8 5 41 3mm x 486mm x 216mm Sixteen 16 Output Rack Mount Configuration Reference Chart Altronix Model Number Output Vol...

Page 3: ...ed master power disconnect circuit breaker to the OFF position Fig 1c pg 4 8 Connect the power output of terminals marked 1 to the power input of device Fig 1b pg 4 Repeat this step for each additional device Outputs 2 16 9 Upon completion of wiring set illuminated master power disconnect circuit breaker to the ON RESET position Fig 1c pg 4 10 The power LEDs on the faceplate for Outputs 1 8 will i...

Page 4: ...wer disconnect circuit breaker switch OFF position Circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated 1d IEC 320 Connector 220VAC 50 60Hz grounded line cord included 1e Removable Terminal Block Fig 1 VertiLine33DV VertiLine33TDV VertiLine63DV and VertiLine63TDV front 1a 1b 1c 1d 1e Removable Terminal Block ...

Page 5: ...n Guide 5 Fig 2 Typical Application Drawing 12VDC VertiLine33DV VertiLine33TDV or 24VDC VertiLine63DV VertiLine63TDV Power Outputs to Devices 12VDC VertiLine33DV VertiLine33TDV or 24VDC VertiLine63DV VertiLine63TDV Power Outputs to Devices ...

Page 6: ...s not powered To reset circuit breaker set power switch to the ON RESET position Fig 3 pg 6 The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is ...

Page 7: ... Left Remove Wall Mount Installation 1 Install mounting brackets A on the left and right side of rack chassis using two 2 flat head screws B included Fig 5a 2 Place unit at desired location and secure with mounting screws not included Fig 5b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing Fig 5 Fig 5a Fig 5b B A Fig 6 Shelf Installation 1 Positi...

Page 8: ...Notes Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty IIVertiLine33DV 63DV Series K04U MEMBER ...