background image

 

TroveKS 

- 5 - 

eFlow Power Supply/Chargers can be Controlled and Monitored while 

Reporting Power/Diagnostics from Anywhere over the Network...

LINQ2 Mounts Inside any Trove Enclosure

LINQ2 - Network Communication Module

LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep 
systems up and running at optimal levels. It facilitates fast and easy installation and set-up, mini-
mizes system downtime, and eliminates unnecessary service calls, which helps reduce Total Cost 
of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR). 

LINQ2 

Features:

-  UL Listed in the U.S. and Canada.
-  Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
-  Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, 
  output state change and unit temperature.
-  Access control and user managment: Restrict read/write, Restrict users to specific resources
-  Two (2) integral network controlled Form “C” Relays.
-  Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
-  Email and Windows Dashboard notifications
-  Event log tracks history.
-  Secure Socket Layer (SSL).
-  Programmable via USB or web browser - includes operating software and 6 ft. USB cable.

LINQ2 Module

Altronix eFlow

Power Supply

Network Connection:

Installation, Programming

and Monitoring

Summary of Contents for TROVE Trove2KS2

Page 1: ...tallation Guide All registered trademarks are property of their respective owners More than just power Installing Company ______________________ Service Rep Name ______________________________________...

Page 2: ...Code NFPA 70 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill ho...

Page 3: ...Mount boards to standoffs utilizing 5 16 pan head screws provided Fig 2a pg 3 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Altronix Board Pem...

Page 4: ...ke sure that they are mounted correctly as shown in Fig 3 below 3 Mount backplane to enclosure with hardware If use of NXTWI or NXTRM3 expansion boards is desired there is no need to remove NXT 2D MSC...

Page 5: ...es UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery sta...

Page 6: ...6 TroveKS Notes...

Page 7: ...25 375 644 6mm 19 375 492 1mm 12 625 320 7mm 0 45 11 4mm 1 0 25 4mm 1 0 25 4mm 9 2 233 7mm 8 5 215 9mm 16 25 412 8mm 0 156 3 96mm 9 2 233 7mm 7 5 190 5mm 0 45 11 4mm TKS2 Dimensions H x W x D 25 375...

Page 8: ...50 8mm 2 00 50 8mm 5 25 133 35mm 5 25 133 35mm 7 00 177 79mm 2 00 50 8mm 2 00 50 8mm 27 00 685 8mm 3 50 88 9mm 0 5625 14 29mm 2 415 61 34mm 0 685 17 399mm 1 77 44 96mm 3 50 88 9mm 21 50 546 1mm 19 80...

Reviews: