Altronix Trove T2ZK7F8 Installation Manual Download Page 8

 

- 8 -  

Trove ZKTeco Kits Installation Guide

6.75” (171.5mm)

8.25” (209.5mm)

8.00” (203.2mm)

2.00” (50.8mm)

2.00” (50.8mm)

1.25” (31.8mm)

1.25” (31.8mm)

5.25” (133.4mm)

5.25” (133.4mm)

7.00” (177.8mm)

1.25” (31.8mm)

6.25” (158.8mm)

19.80” (502.9mm)

1.00” (25.4mm)

27” (685.8mm)

1.5”

(38.1mm)

2.00” (50.8mm)

2.00” (50.8mm)

3.5”(88.9mm) 3.5”(88.9mm)

21.50” (546.1mm)

5.25” (133.35mm)

5.25” (133.35mm)

6.25” (158.8mm)

1.25”

(31.8mm)

0.85” (21.6mm)

0.5625” (14.3mm)

   2.415” (61.3mm)

0.685” (17.4mm)

1.77”

(45mm)

0.885” (22.5mm)

1.125” (28.3mm)

Knockouts

2.00” (50.8mm)

2.00” (50.8mm)

Enclosure Dimensions 

(H x W x D)

:

27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm)

Altronix is not responsible for any typographical errors.

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

web site: www.altronix.com | e-mail: [email protected] | Lifetime Warranty

IITrove ZKTeco Kits 

J22U

MEMBER

Summary of Contents for Trove T2ZK7F8

Page 1: ...Power Controllers One 1 VR6 Voltage Regulator One 1 PDS8 Dual Input Fused Power Distribution Module All components of this Trove kit are UL Listed sub assemblies Please refer to the included correspon...

Page 2: ...sdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill holes in the wall to line up with the top two three keyholes in the enclo...

Page 3: ...UTPUT 6 OUTPUT 7 OUTPUT 8 NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 INPUT...

Page 4: ...M NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 INPUT TRIGGER 10A 250V INP T RET NO C NC F...

Page 5: ...ER 10A 250V INP T RET NO C NC FACP INTERFACE Power Control F1 F2 F3 F4 F5 F6 F7 F8 MAIN TRG FACP 1 2 3 4 1 2 3 4 O N O N 1 2 3 4 1 2 3 4 O N O N OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 O...

Page 6: ...NTERFACE Power Control F1 F2 F3 F4 F5 F6 F7 F8 MAIN TRG FACP 1 2 3 4 1 2 3 4 O N O N 1 2 3 4 1 2 3 4 O N O N OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 NC C NO COM NC C NO...

Page 7: ...MR LINQ2 Features UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current...

Page 8: ...1mm 5 25 133 35mm 5 25 133 35mm 6 25 158 8mm 1 25 31 8mm 0 85 21 6mm 0 5625 14 3mm 2 415 61 3mm 0 685 17 4mm 1 77 45mm 0 885 22 5mm 1 125 28 3mm Knockouts 2 00 50 8mm 2 00 50 8mm Enclosure Dimensions...

Reviews: