Altronix Trove T2ZK7F8 Installation Manual Download Page 2

 

- 2 -  

Trove ZKTeco Kits Installation Guide

Overview:

Altronix T2ZK7F8 and T2ZK7F16 Trove ZKTeco kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix 

power supply/chargers and sub-assemblies. 

T2ZK7F8 accommodates up to two (2) ZKTeco modules for up to eight (8) doors in a single enclosure.

T2ZK7F16 accommodates up to four (4) ZKTeco modules for up to sixteen (16) doors in a single enclosure.

Configuration Chart:

Altronix

Model Number

120VAC 60Hz Input Current (A)

Power Supply Board Input Fuse Rating

Power Supply Board Battery Fuse Rating

Maximum Supply

Current for Main and 

Aux. Outputs on 

Power Supply board 

and ACM8 Access 

Power Controllers’ 

outputs

Nominal DC Output 

Voltage

Fail-Safe/Fail-Secure  or Dry Form “C”  Outputs

Additional Fused  Outputs

ACM8 Board  Input Fuse Rating

ACM8 Board Output Fuse Rating

PDS8 Board Input Fuse Rating

PDS8 Board Output Fuse Rating

[DC]

[Aux]

Output 

Range 

(VDC)

Output 

Range 

(VDC)

T2ZK7F8

4.5 6.3A/

250V

15A/

32V

24VDC @ 9.7A

20.17-26.4 20.28-26.4

8

8

10A/

250V

2.5A/

250V

10A/

32V

3A/

32V

T2ZK7F16

24VDC @ 9.4A

16

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. 

Product is intended for indoor use only. 

1.  Remove backplane from enclosure. Do not discard hardware.

2.  Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and 

  screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper screws; 

  level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three 

  fasteners. Place the enclosure’s upper keyholes over the two/three upper screws. Install the three lower screws and make sure to 

  tighten all screws.

3.  Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired 

  location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure 

  approximately 2” from the right side 

(Fig. 1, pg. 2)

. Connect tamper switch wiring to the 

  Access Control Panel input or the appropriate UL Listed reporting device. 

  To activate alarm signal open the door of the enclosure.

4.  Mount ZKTeco modules to backplane, refer to

 pages 3 - 6

.

5.  Refer to the 

eFlow Power Supply/Charger Installation Guide

 for eFlow104NB and 

 corresponding 

Sub-Assembly Installation Guides

 for ACM8, PDS8 and VR6 for 

  further installation instructions. 

Hardware:

Fig. 1

Tamper Switch

(provided)

To Access Control Panel or

UL Listed Reporting Device

Edge of

Enclosure

Enclosure

Nylon Spacer |            5/16” Pan Head Screw |         Lock Nut

Summary of Contents for Trove T2ZK7F8

Page 1: ...Power Controllers One 1 VR6 Voltage Regulator One 1 PDS8 Dual Input Fused Power Distribution Module All components of this Trove kit are UL Listed sub assemblies Please refer to the included correspon...

Page 2: ...sdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill holes in the wall to line up with the top two three keyholes in the enclo...

Page 3: ...UTPUT 6 OUTPUT 7 OUTPUT 8 NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 INPUT...

Page 4: ...M NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 INPUT TRIGGER 10A 250V INP T RET NO C NC F...

Page 5: ...ER 10A 250V INP T RET NO C NC FACP INTERFACE Power Control F1 F2 F3 F4 F5 F6 F7 F8 MAIN TRG FACP 1 2 3 4 1 2 3 4 O N O N 1 2 3 4 1 2 3 4 O N O N OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 O...

Page 6: ...NTERFACE Power Control F1 F2 F3 F4 F5 F6 F7 F8 MAIN TRG FACP 1 2 3 4 1 2 3 4 O N O N 1 2 3 4 1 2 3 4 O N O N OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 NC C NO COM NC C NO...

Page 7: ...MR LINQ2 Features UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current...

Page 8: ...1mm 5 25 133 35mm 5 25 133 35mm 6 25 158 8mm 1 25 31 8mm 0 85 21 6mm 0 5625 14 3mm 2 415 61 3mm 0 685 17 4mm 1 77 45mm 0 885 22 5mm 1 125 28 3mm Knockouts 2 00 50 8mm 2 00 50 8mm Enclosure Dimensions...