Altronix TROVE T1RHW3F4 Installation Manual Download Page 5

 

T1RHW3F4 Installation Guide 

- 5 -

T1RHW3F4: 

Configuration of Honeywell Boards

1.  Fasten spacers onto metal pems configuration (A) of backplane depending on the access controller 

 

(Fig. 5, pg. 5)

.

2.  Position access controller module over corresponding spacers and fasten screws into spacers 

(Fig. 5a, pg. 5)

.

3.  Fasten THW1R backplane to Trove1R rack enclosure utilizing hardware (provided).

Access Controller Position Chart for the Following Models:

Honeywell Board

Pem Mounting

PRO32E1PS, PRO32IC, PRO32R2, PRO32IN, PRO32OUT, PW6K2E2PS, PW6K1IC, 

PW6K1IN, PW6K1OUT, PW6K1R2.

A

Fig. 5

A

A

Altronix

eFlow6NB

AC

         G         

N

DC

AC

1

1 mi

n

enable 2 hr

.

disable  

 

OFF - 24V

ON - 12V

ON

TRIGGER EO

L

SUPERVISED

- --  BA

T +

- --  DC 

+

NC        C        NO

AC F

AIL

NC        C        NO

BA

FA

IL

AUX  

---

NO      GND

RESET

Altronix PDS8/VR6

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

OUT8

8

Common Power Outputs (NEG)

P

N

+ INP1 -            + INP2 

-

PWR1+

PWR2+

COM(-)

PWR1+

COM(-)

P

N

PWR1+

VR6 is mounted

under PDS8

Altronix ACM4

--- 

+

Contro

l

--- 

+

Po

we

r

NO        C        NC

FACP

INTERF

ACE

+ INP 

--- 

 

+ RET 

--- 

  

TRG

TRIGGER

INPUT

IN  GND

1

NC 

NO 

COM

OUTPUT 1

NC 

NO 

COM

OUTPUT 2

NC 

NO 

COM

OUTPUT 3

NC 

NO 

COM

OUTPUT 4

IN  GND

3

IN  GND

4

IN  GND

2

ACM4

ACCESS POWER

CONTROLLER

RoHS

MAIN

To IEC connector

To LED

lense

Pem

Spacer

Backplane

Pan Head Screw

Honeywell

Board

Fig. 5a

Reviews: