T1KE34/38 / T2KE3316 Installation Guide
Overview:
Altronix Trove Kisi kits are pre-assembled and consists of Trove1LU1 or Trove2LU2 enclosure/backplane with factory installed Altronix power
supply/charger and sub-assemblies. Trove Kisi kits also accommodates up to four (4) Kisi Pro Controllers for up to sixteen (16) doors in a single
enclosure.
Configuration Chart:
Altronix
Model
Number
Power
Supply
Board
Input
Fuse
Rating
Power
Supply
Board
Battery
Fuse
Rating
115VAC
60Hz
Input
Current
(A)
Maximum Supply
Current for Main Output on
Power Supply board
and ACM4/ACM8 Access
Power Controllers’ outputs
Nominal DC
Output Voltage
Fail-Safe/
Fail-Secure
Outputs
ACM4/
ACM8
Board
Input
Fuse
Rating
ACM4/
ACM8
Board
Output
Fuse
Rating
[DC]
[Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T1KE34
5A/
250V
10A/
32V
3.5
24VDC @ 6A
20.17-
26.4
20.28-
26.4
4
10A/
250V
3A/
32V
T1KE38
8
T2KE3316
16
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having juris-
diction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners
and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper
screws, level and secure. Mark the position of the lower two/three holes. Remove the enclosure. Drill the lower holes and
install the two/three fasteners. Place the enclosure’s upper keyholes over the two/three upper screws. Install the two/three lower
screws and make sure to tighten all screws refer to
pages 6-7
.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge
of the enclosure, approximately 2” from the right side
(Fig. 1, pg. 2)
.
Connect tamper switch wiring to the Access Control Panel input or the
appropriate UL Listed reporting device. To activate alarm signal
open the door of the enclosure.
4. Mount Kisi Pro Controllers to TLU1 or TLU2 backplane, refer to
pages 3-5
.
5. Refer to the
ULXB Power Supply/Charger Installation Guide
for AL600ULXB
and corresponding
Sub-Assembly Installation Guides
for ACM4/ACM8 for
further installation instructions.
Fig. 1
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure