Trove2PX2 / TPX2 Installation Guide

Overview:

Trove2PX2 accommodates Paxton Net2 Plus boards with or without Altronix power supplies and accessories for access control systems. 

Agency Listings:

•   UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.

    *Stand-by Power Level I if no battery is supplied.

•   This Class B digital apparatus complies with Canadian ICES-003. 

    Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada.

•   CE European Conformity. 

Installation Instructions for Trove2:

1.  Remove backplane from enclosure prior to mounting (do not discard hardware).

2.  Mark and predrill holes in the wall to line up with the top keyholes in the enclosure. Install the upper fasteners and screws in the wall 

 

with the screw heads protruding. Place the enclosure’s upper keyholes over the screws; level and secure. Mark the position of the lower 

 

holes. Remove the enclosure. Drill the lower holes and install the fasteners. Place the enclosure’s upper keyholes over the upper screws. 

 

Install the lower screws and make sure to tighten all screws 

(Enclosure Dimensions, pg. 4)

.

3.  Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. 

 

Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side 

(Fig. 1, pg. 2)

 

Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. 

 

To activate alarm signal open the door of the enclosure.

4.  Mount Altronix/Paxton boards to backplane, refer to

 page 3.

Fig. 1

Tamper Switch

(provided)

To Access Control Panel or

UL Listed Reporting Device

Edge of

Enclosure

Enclosure

Summary of Contents for TROVE 2PX2

Page 1: ...ng Company __________________________ Service Rep Name ___________________________________________ Address __________________________________________________________ Phone __________________________ All registered trademarks are property of their respective owners More than just power Installation Guide Access Power Integration ...

Page 2: ...screws in the wall with the screw heads protruding Place the enclosure s upper keyholes over the screws level and secure Mark the position of the lower holes Remove the enclosure Drill the lower holes and install the fasteners Place the enclosure s upper keyholes over the upper screws Install the lower screws and make sure to tighten all screws Enclosure Dimensions pg 4 3 Mount included UL Listed ...

Page 3: ...t positions Fig 2 pg 2 Note Paxton Net2 Plus modules have one 1 RJ45 jack and one 1 switch each Please make sure that they are mounted correctly as shown in Fig 2 below 4 Fasten TPX2 backplane to Trove2 enclosure utilizing pan head screws provided Fig 2 Trove2PX2 TPX2 Configurations Pem Spacer Power Supply or Sub Assembly Backplane Pan Head Screw Metal Spacer Placement Altronix Power Supply Metal ...

Page 4: ... 546 1mm 5 25 133 35mm 5 25 133 35mm 6 25 158 8mm 1 25 31 8mm 0 85 21 6mm 0 5625 14 3mm 2 415 61 3mm 0 685 17 4mm 1 77 45mm 0 885 22 5mm 1 125 28 3mm Knockouts 2 00 50 8mm 2 00 50 8mm Trove2PX2 Enclosure Dimensions H x W x D 27 25 x 21 75 x 6 5 692 2mm x 552 5mm x 165 1mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718...

Reviews: