R248/2416ULi series 

- 3 - 

XFMR* 

ALTRONIX CORP.

BROOKLYN, NY 11220

MADE IN USA

XFMR* 

AC Power 

LED's 

AC Power 

LED's 

AC Power 

LED's 

AC Power 

LED's 

Removable Terminal 

Block 

Strain Relief 

Line Cord 

(Green Wire

Earth GND)

 PTC1 

Used  

on PTC  

Models 

5A 

250V 

Illuminated 

Power Disconnect 

Circuit Breaker with 

manual reset

Fig. 1

Fig. 1a

Fig. 1b

Fig. 1c

Fig. 1d

9.  Power switch with built-in circuit breaker:
  OFF position - Switch not illuminated. Outputs not powered.
  RESET (ON) position - Switch illuminated. Outputs powered.
  Circuit breaker tripped - Switch not illuminated. Power LEDs on faceplate are not illuminated. Outputs not powered.
  To reset circuit breaker set power switch to the ON (RESET) position (Fig. 1c, pg. 3).

CAUTION:  Equipment to be installed/serviced by authorized personnel only.
 

Shut brunch circuit power berfore servicing/installing equipment.

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or 

moisture. This installation should be made by qualified service personnel and should conform to 

all local codes and in accordance with the National Electrical Code.

Fuse ratings:

Replace output fuses with the same type and rating 3.5A/250V.

Replace primary in-line fuse with the same type and rating 5A/250V.

 The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
 presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient
 magnitude to constitute an electric shock.

 The exclamation point within an equilateral triangle is intended to alert the user to the presence of important  
 operating and maintenance (servicing) instructions in the literature accompanying the appliance.

 CAUTION: To reduce the risk of electric shock do not open enclosure. There are
 

no user serviceable parts inside. Refer servicing to qualified service personnel.

3.5A 250V

Output Rating

5A 250V

Summary of Contents for R248ULi

Page 1: ...24VAC 12 5 amp 300VA total output 300VA total output Eight 8 1 56 amp Fuse Eight 8 1 56 amp PTC Protected Isolated Outputs Protected Isolated Outputs R2416ULi R2416ULCBi 24VAC 25 amp 24VAC 25 amp 600VA total output 600VA total output Sixteen 16 1 56 amp Fuse Sixteen 16 1 56 amp PTC Protected Isolated Outputs Protected Isolated Outputs ...

Page 2: ...fix P 1P 2P are the same phasing 5 Set power switch on the back of the unit to the OFF position Fig 1c pg 3 6 Connect devices to the removable terminal blocks marked 1P 1N through 16P 16N Fig 1a pg 3 When wiring is completed on thge terminal blocks they can be locked down by tightening screw flanges 7 Upon completion of the wiring set power switch on the back of the unit to the ON RESET position F...

Page 3: ... reduce the risk of fire or electric shock do not expose the unit to rain or moisture This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Code Fuse ratings Replace output fuses with the same type and rating 3 5A 250V Replace primary in line fuse with the same type and rating 5A 250V The lightning flash...

Page 4: ... USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIR248 2416 UL Listed Isolated Rack Mount Series J08M MEMBER 8 5 215 9mm 0 75 19 05mm 19 125 485 8mm 17 625 447 8mm 3 26 82 8mm Rack Mechanical Drawing and Dimensions H x W x D 3 26 x 19 125 x 8 5 83mm x 486mm x 216mm ...

Reviews: