Overview:

These Altronix Rack Mount CCTV Power Supplies provide 24VAC distributed via mutltiple fuse or PTC protected 
isolated outputs for powering CCTV Cameras, heaters and other video accessories.

UL Listed Isolated Rack Mount Configuration Reference Chart:

Altronix 

Model Number

Output Voltage (VAC)

Total 

 Output Current

(Power)

Number of Outputs

PTC Protected Outputs  (Class 2 power limited for  Dry locations).  (Class 3 for Wet locations).

Fuse Protecte Class 1  Outputs

Output Current (max per  output)

Fuse Ratings

Primary In-line Fuse  Ratings

115VAC 50/60Hz Input  Current

Agency Listings

R248ULi

24VAC

12.5 amp

(300VA)

8

---

Yes 1.56 amp 3.5 amp

5 amp/

250V

2.7 amp

R248ULCBi

24VAC

12.5 amp

(300VA)

8

Yes

---

1.56 amp

---

5 amp/

250V

2.7 amp

R2416ULi*

24VAC

25 amp

(600VA)

16

---

Yes 1.56 amp 3.5 amp

5 amp/

250V

5.4 amp

R2416ULCBi*

24VAC

25 amp

(600VA)

16

Yes

---

1.56 amp

---

5 amp/

250V

5.4 amp

*Outputs 1-8 provide 12.5 amp (300VA) max. Outputs 9-16 provide 12.5 amp (300VA) max.

Specifications:

Installation Instructions:

1.  Mount unit in the desired rack location (Space unit at least 3” from any video monitors).
2.  Set power switch on the back of the unit to the OFF position (Fig. 1c, pg. 3).
3.  Plug power cord into a grounded 115VAC 50/60 Hz receptacle (Fig. 1b, pg. 3).
4.  Set power switch on the back of the unit to the ON (RESET) position and measure output voltage before 
  connecting devices (Fig. 1c, pg. 3). This helps avoiding potential damage. 
  All terminals with common suffix (P) “1P, 2P...” are the same phasing.
5.  Set power switch on the back of the unit to the OFF position (Fig. 1c, pg. 3).
6.  Connect devices to the removable terminal blocks marked [1P & 1N through 16P & 16N] (Fig. 1a, pg. 3).
  When wiring is completed on thge terminal blocks they can be locked down by tightening screw flanges.
7.  Upon completion of the wiring, set power switch on the back of the unit to the ON (RESET) position (Fig. 1c, pg. 3).
8.  Green power LEDs on faceplate will illuminate when AC power is present. When an output is in a trouble condition 
  (blown fuse or tripped PTC), the corresponding LED will not be illuminated (Fig. 1, pg. 3).
  a.  Blown fuse (R248ULi & R2416ULi) - Set power switch the on back of the unit to the OFF position (Fig. 1c, pg. 3).
  
Remove front faceplate to access fuses. Replace with fuses rated @ 3.5A/250VA (Altronix model # Fuse1).
  b.  Tripped PTC (R248ULCBi & R2416ULCBi) - To reset PTC, set power switch on the back of the unit to 
    the OFF position. After approximately 30 secs. set power switch to the ON (RESET) position (Fig. 1c, pg. 3).

Agency Listings:

• UL Listed for Commercial CCTV Equipment (UL 2044).
• CUL Listed - CSA Standard C22.2 No.1-98, Audio,
  Video and Similar Equipment.
•  CE European Conformity.

Input:

•  115VAC, 50/60Hz, 5.4 amp.

Output:

•  Individual electronically isolated outputs.
•  24VAC supply current.
•  Surge suppression.

Features:

•  Individual power LED indicators.
•  Illuminated master power disconnect circuit breaker
  with manual reset.
•  3-wire grounded line cord.
•  Removable terminal blocks with locking screw flange.
•   Spare fuses provided.

Mechanical:

•  2U rack mount chassis for use in a standard EIA 19” rack.
•  Enclosure Dimensions (H x W x D approx.):
  3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)

Summary of Contents for R248ULi

Page 1: ...24VAC 12 5 amp 300VA total output 300VA total output Eight 8 1 56 amp Fuse Eight 8 1 56 amp PTC Protected Isolated Outputs Protected Isolated Outputs R2416ULi R2416ULCBi 24VAC 25 amp 24VAC 25 amp 600VA total output 600VA total output Sixteen 16 1 56 amp Fuse Sixteen 16 1 56 amp PTC Protected Isolated Outputs Protected Isolated Outputs ...

Page 2: ...fix P 1P 2P are the same phasing 5 Set power switch on the back of the unit to the OFF position Fig 1c pg 3 6 Connect devices to the removable terminal blocks marked 1P 1N through 16P 16N Fig 1a pg 3 When wiring is completed on thge terminal blocks they can be locked down by tightening screw flanges 7 Upon completion of the wiring set power switch on the back of the unit to the ON RESET position F...

Page 3: ... reduce the risk of fire or electric shock do not expose the unit to rain or moisture This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Code Fuse ratings Replace output fuses with the same type and rating 3 5A 250V Replace primary in line fuse with the same type and rating 5A 250V The lightning flash...

Page 4: ... USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIR248 2416 UL Listed Isolated Rack Mount Series J08M MEMBER 8 5 215 9mm 0 75 19 05mm 19 125 485 8mm 17 625 447 8mm 3 26 82 8mm Rack Mechanical Drawing and Dimensions H x W x D 3 26 x 19 125 x 8 5 83mm x 486mm x 216mm ...

Reviews: