Overview:

Altronix NetWay1DWP Outdoor Single Port Midspan Injector provides Hi-PoE (60W) power and passes data 
for PoE compliant cameras/edge devices . Cameras/edge devices may be located up to 100m from the unit .

Features:

Agency Listings:

• 

UL 60950-1 

Information Technology

   

Equipment . 

 

UL 60950-22 

Information Technology

     

Equipment to be installed

   

Outdoors .

• 

CE  

European Conformity .

Input:

•  115VAC, 60Hz, 1 .2A or
  230VAC, 50/60Hz, 0 .75A .

Power Output:

•  Maximum power: Hi-PoE (60W) . Power product
  using all 4 pairs for 60W .
•  IEEE 802 .3at (30W) and 
  IEEE 802 .3af (15W) compliant .
•  Integral surge protection .

Ethernet:

•  Connectivity: RJ45, auto-crossover .
•  Wire type: 4-pair Cat-5 or better structured cable .
•  Distance: up to 100m .
• Speed: 10/100/1000Mbps, half/full duplex,
  auto negotiation .

LEDs:

•  LED1: PoE active . 
  LED2: AC Power present .

Environmental:

• 

Operating Temperature:

    30W: 

-30ºC to 70ºC (-22ºF to 158ºF) .

    60W: 

-30ºC to 55ºC (-22ºF to 131ºF) .

• 

Storage Temperature: 

     

-30ºC to 85ºC (-22ºF to 185ºF) .

•  Humidity: 

20 to 85%, non-condensing .

Applications:

•  Provides PoE/PoE+ and Hi-PoE for 
 cameras/devices .

Mechanical:

•  NEMA 4X, IP66 Rated enclosure for outdoor use .
•  Dimensions (H x W x D approx .):
  9 .5” x 7 .32” x 4 .92” (241 .3mm x 185 .9mm x 125mm) .

Models:

• NetWay1DWP: Outdoor Single Port Hi-PoE  
 Injector .
• NetWay1DWPH: Outdoor Single Port Hi-PoE
  Injector, enclosure with three (3) 5/8” wiring
  inlets, includes NEMA rated glands .

   Installation  Instructions: 

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes 
and authorities having jurisdiction . Wiring should be UL Listed and/or Recognized wire suitable for the application .
1 .  Remove circuit board from enclosure prior to drilling 

NetWay1DWP (do not discard hardware) .

 

Note: Take care to assure that hardware will not interfere with components of the circuit board .

2 . 

NetWay1DWP: Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 2, pg. 4). 

 

Maximum UL Listed NEMA type 4X rated fittings to be used is 1/2”, follow manufacturer’s specifications 

 

for the appropriate size opening .

 

Note: Inlets for conduit fittings should only be made on the bottom of the enclosure . 

 

UL Listed NEMA type 4X rated conduit connector/hubs shall be used for the appropriate size inlets .

 

NetWay1DWPH is pre-drilled with three (3) pre-drilled inlet holes for wiring .

3 .  Clean out the inside of enclosure before remounting circuit board .
4 .  Switch circuit breaker to the OFF position .
5 .  Connect AC power from a UL approved circuit breaker to the terminals marked [L] and [N],
 

connect ground to the terminal marked [G] (refer to Fig. 1 on right) . 

6 .  Mounting NEMA 4X rated enclosure:
 

Wall mount: Mount unit in desired location . Mark and drill holes to line 

 

up with the top and bottom holes of the enclosure flange . Secure enclosure 

 

with appropriate fasteners (e . g . screws and anchors; bolts and locking 

 

nuts, etc .) which are compatible with mounting surface and are of 

 

sufficient length/construction to ensure a secure mount (Fig. 4, pg. 7) .

 

Pole Mount: refer to page 7 .

 

Note: All inlets for conduit fittings should be on the bottom of the enclosure .

7 .  Mount circuit board in enclosure with hardware .
8 .  To facilitate wire entry utilize weather-tight NEMA rated connectors 
 

(supplied), bushings and cable .

9 .  Connect structured cable from UL Listed ethernet switch or video server to 
 

RJ45 jack marked [IN] on NetWay1DWP/NetWay1DWPH (Fig. 3, pg. 5) .

10 .  Connect structured cable from camera/device to RJ45 jack marked [OUT] on NetWay1DWP/
 NetWay1DWPH/ 

(Fig. 3, pg. 5) .

11 .  Switch circuit breaker to the ON position .

L

G

N

115VAC/230VAC

Input

Line

Neutral

Ground

Fig. 1