background image

- 2 - 

NetWay1 / NetWay1X

 

Note: Return to normal operation from shutdown can take about 4 seconds. Although there is 

  no output voltage to power PoE devices during shutdown, data signals may still be present on 

  the data pair lines of the CAT5e cable.

NetWay1:

Fig. 1

NetWay1X:

Fig. 2

 

NetWay1 Port Status and LED Flash Codes

Port Status

Flash Code

Flash Pattern

Non-Powered Device 
0

Ω

 < RPORT < 200

Ω

OFF

LED OFF

Port Open RPORT > 1M

Ω

OFF

LED OFF

Port On 25k

Ω

ON

LED ON

Low Signature Resistance 
300

Ω

 < RPORT < 15k

Ω

1 Flash

Z

  

 

l l l 

Z

  

 

l l l 

Z

  

 

l l l

High Signature Resistance 
33K

Ω

 < RPORT < 500k

Ω

2 Flashes

Z Z

  

 

l l 

Z Z

  

 

l l 

Z Z

  

 

l l

Port Overload Fault

5 Flashes

 

 

l l l l 

Z Z

 

Z Z Z

  

 

l l l l

Structured

Cable from

Network

Switch

24VAC/

24VDC Input

12VAC to 24VAC or

5VDC to 24VDC Input

for PoE shutdown

Structured Cable from

IP Camera, IP Lock or IP device,

NetWay1512 or NetWayXT

Structured

Cable from

Network

Switch

24VAC/

24VDC Input

12VAC to 24VAC or

5VDC to 24VDC Input

for PoE shutdown

Structured Cable from

IP Camera, IP Lock or IP device,

NetWay1512 or NetWayXT

24VAC/VDC

Input

Power

Shutdown

IN

OUT

Port

Status

General Signaling

Equipment 92R2

I.T.E. 43KC

NetWay1

Single Port Injector (Midspan)

24VAC/VDC, 1.2A Input
48VDC 15.4W max. per IEEE 802.3af

www.altronix.com

Equipment 92R2

Access Control PoE Injector

Attack Class 

I

 

Fig. 1a

Fig. 1b

Fig. 1c

Structured

Cable from

Network

Switch

24VAC/

24VDC Input

12VAC to 24VAC or

5VDC to 24VDC Input

for PoE shutdown

Structured Cable from

IP Camera, IP Lock or IP device

Power In LED

PoE LED

24VAC/VDC

Input

Power

Shutdown

IN

OUT

NetWay1X

Single Port Injector (Midspan)

Input: 

24VAC/VDC, 1.5A

Output: 

IEEE 802.3at (30W) and

 

IEEE 802.3af (15.4W)

 

compliant.

I.T.E. 43KC

Z109

Made in U.S.A.

www.altronix.com

Fig. 2a

Fig. 2b

Summary of Contents for NetWay1

Page 1: ...jurisdiction Wiring should be UL Listed and or Recognized wire suitable for the application Unit is intended to be used with a UL Listed Class 2 or LPS limited power supply NetWay1 NetWay1X is not intended to be connected to outside plant leads and should be installed indoors within the protected premises NetWay1 NetWay1X is intended for indoor use only 1 Mount NetWay1 NetWay1X in desired location...

Page 2: ...Network Switch 24VAC 24VDC Input 12VAC to 24VAC or 5VDC to 24VDC Input for PoE shutdown Structured Cable from IP Camera IP Lock or IP device NetWay1512 or NetWayXT St Ca N 24VAC 24VDC Input IP C N 24VAC VDC Input Power Shutdown IN OUT Port Status General Signaling Equipment 92R2 I T E 43KC NetWay1 Single Port Injector Midspan 24VAC VDC 1 2A Input 48VDC 15 4W max per IEEE 802 3af www altronix com E...

Page 3: ... UL294 application NetWay1 only NVR Network Server Network Switch NetWay1 CAT5e 100m Port shutdown input UL Listed Access Control Power Limited Power Supply 24VDC 24VAC Card Reader Electric Strike HID Solo Edge Device Video Monitor NVR Network Server Network Switch NetWay1 NetWay1X PoE Camera CAT5e 100m Port shutdown input 24VAC 24VDC input Video Monitor NVR Network Server Network Switch NetWay1 N...

Page 4: ...ne 1 Input power requirements NetWay1 24VAC 1 2A or 24VDC 1 2A NetWay1X 24VAC 1 5A or 24VDC 1 5A Indicators Port Status LED Power In LED NetWay1X only PoE Shutdown Voltage and Current Range 5VDC to 24VDC or 12VAC to 24VAC Maximum current 2mA for 5VDC Maximum current for higher voltages 10mA Environmental Conditions Operating Ambient Temperature NetWay1 UL60950 1 0ºC to 40ºC 32ºF to 104ºF UL294 0ºC...

Reviews: