background image

 

- 2 - 

NetWay8V / NetWay16V Installation Guide

Overview:

Altronix NetWay8V/NetWay16V Midspans provide power and pass data for PoE compliant cameras/edge devices. 

Cameras/edge devices may be located up to 100m from the NetWay unit. A NetWayXT/NetWayXTX repeater module 

can be utilized to extend the distance an additional 100m for a total range of up to 200m. A maximum range of 600m 

is possible using multiple repeaters, based on camera/device port requirement. NetWay Midspans are capable of 

supporting non-PoE compliant fixed and PTZ IP cameras utilizing NetWay1512 or NetWay3012 adapters.

NetWay Specifications:

NetWay8:

•  Eight (8) ports of cameras/edge devices over ethernet (CAT5) cable up to a distance of 100m per port.

•  Input: 220VAC 50/60Hz, 1.8A.

NetWay16:

•  Sixteen (16) ports of cameras/edge devices over ethernet (CAT5) cable up to a distance of 100m per port. 

•  Input: 220VAC 50/60Hz, 2.5A

.

Common Specifications:

Agency Listings:

• 

CE

  

European Conformity.

Power:

•  Unit supplies PoE output voltage (55V), and up to

  30W max. full power per port.

  Total power: 

NetWay8V - 150W, 

   

NetWay16V - 300W.

•  IEEE 802.3af (PoE) and 

  IEEE 802.3at (PoE+) compliant.

•  All output circuits are power-limited.

•  Short circuit protection.

Functions:

•  Auto detection and protection of legacy

  non-PoE cameras/edge devices.

Features:

•  Illuminated master power disconnect circuit 

  breaker with manual reset (switch).

Features 

(cont’d)

:

•  Individual port status LEDs.

•  IEC 320 - 3-wire grounded line cord (detachable).

•  Unit can be rack or shelf mounted.

•  1U rack mount chassis for use in standard 

  EIA 19” rack.

Accessories:

NetWay1512:

•  15W adapter for non-PoE compliant IP cameras.

NetWay3012:

•  25W adapter for non-PoE compliant IP 

  fixed or PTZ cameras.

NetWayXT:

•  PoE repeater module extends range 100m.

NetWayXTX:

•  PoE+ repeater module extends range 100m.

Installation Instructions:

NetWay is not intended to be connected to outside plant leads.

1. Attach mounting brackets to NetWay unit for rack installation 

(Fig. 6, pg. 8)

.

  Affix rubber pads to NetWay for shelf installation 

(Fig. 8, pg. 7)

.

2. Secure the unit in a rack or place unit on a shelf as desired.

 

Note:

 The following factors should be taken into consideration when installing these rack mount units:

  a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC).

  b. Take care to ensure that there is sufficient air flow around the unit and that obstructions do not impede it.

  c. When mounting units in rack, take care to avoid uneven loading which can cause a hazardous condition.

3. Set illuminated master power disconnect circuit breaker to the (OFF) position 

(Fig. 1d, pg. 3)

.

4. Plug the grounded AC line cord (included) into the IEC 320 connector of the NetWay unit 

(Fig. 1e, pg. 3)

  Plug unit into a reliable earth grounded socket. When using multiple units, the sum of the individual name 

  plate ratings should not exceed the supply circuit rating. Do not connect to a receptacle controlled by a switch.

5. Connect structured cables from port marked [IN] on NetWay to the corresponding inputs of an ethernet 

  switch or video server 

(Fig. 1b, pg. 3, Fig. 5, pg. 6)

.

6. Connect structured cables from port marked [OUT] on NetWay to PoE compliant camera/edge devices 

 

(Fig. 1a, pg. 3, Fig. 5, pg. 6)

7. Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) 

 position 

(Fig. 1d, pg. 3)

.

8. Port status LEDs on the NetWay will initialize when PoE devices are connected as follows:

  -  LED will illuminate when devices are IEEE 802.3af compliant.

  -  LED will blink once and illuminate when devices are IEEE 802.3at compliant (PoE+).

Summary of Contents for NetWay V Series

Page 1: ...______________ Address ______________________________________________ Phone ___________________ Installation Guide Power over the Ethernet NetWay V Series PoE Solution for Standard Network Infrastruct...

Page 2: ...eras NetWayXT PoE repeater module extends range 100m NetWayXTX PoE repeater module extends range 100m Installation Instructions NetWay is not intended to be connected to outside plant leads 1 Attach m...

Page 3: ...LED s 1 8 Power Supply Overload for ports 1 8 LED s 9 16 Power Supply Overload for ports 9 16 Fig 1 NetWay8V NetWay16V Configuration AC POWER NetWay8V NetWay16V Rear Panel NetWay8V Front Panel NetWay...

Page 4: ...12 in proximity to IP camera utilizing mounting hole Fig 3 pg 4 Use a proper fastener and or wall anchor when securing NetWay3012 to the wall 2 Connect structured cable from port marked IN on NetWay30...

Page 5: ...er to LED Definitions 5 Power LED will illuminate indicating 12VDC output Port LED Definitions for NetWayXT Repeater Status Green LED Yellow LED OFF Indicates it is connected as 10Base T or no link In...

Page 6: ...nvironmental Conditions Operating Ambient Temperature 20 C to 40 C 4 F to 104 F Relative humidity 85 5 Storage Temperature 20 to 70 C 4 to 158 F Operating Altitude 304 8 to 3 048m Regulatory Complianc...

Page 7: ...presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is i...

Page 8: ...ace unit at desired location and secure with 6 size screws or larger not included Fig 8b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit v...

Reviews: