Overview:

ALTV615DC220 Series DC CCTV Power Supplies provide 6-15VDC distributed via fuse or PTC protected outputs for 
powering CCTV cameras, heaters, and other video accessories.

ALTV615DC220 Reference Chart:

Altronix 

Model Number

Output 

Voltage

Total 

 Output 

Current

(Power)

Number

of

Outputs

PTC 

Protected

Outputs

Fuse 

Protected

Outputs

Output 

Current

(max per 

output)

220VAC 

50/60Hz 

Input 

Current

ALTV615DC44M220

6-15VDC

4A

4

-

P

3.5A

0.5A

ALTV615DC44CBM220

6-15VDC

4A

4

P

-

2.5A

0.5A

ALTV615DC48M220

6-15VDC

4A

8

-

P

3.5A

0.5A

ALTV615DC48CBM220

6-15VDC

4A

8

P

-

2.5A

0.5A

ALTV615DC416220

6-15VDC

4A

16

-

P

3.5A

0.5A

ALTV615DC416CB220

6-15VDC

4A

16

P

-

2.5A

0.5A

ALTV615DC616220

6-15VDC

6A

16

-

P

3.5A

1A

ALTV615DC616CB220

6-15VDC

6A

16

P

-

2.5A

1A

ALTV615DC1016220

6-15VDC

10A

16

-

P

3.5A

1A

ALTV615DC1016CB220

6-15VDC

10A

16

P

-

2.5A

1A

Specifications:

CAUTION: This installation should be made by qualified service personnel and should conform to the 

National Electrical Code and all local codes.

Installation Instructions:

1.  Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
 

enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s    

 

upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the    

 

enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two

 

upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 7, 8).

2.  Remove Power Distribution Module and isolation barrier (models with “M” suffix only).
3.  Connect unswitched AC circuit (220VAC, 50/60Hz) as follows: Green branch wire (ground) connects to the terminal 
 

marked     , Line connects to the terminal marked [L], and Neutral connects to the terminal marked [N] of the Inlet 

 

Appliance Connector. (Figs. 1-4, pgs. 4-6). Use 18 AWG or larger for all power connections.

 

 

Units with line cord installed skip Instruction #3.

 

Use 18 AWG or larger for all power connections. Connect green ground lead to earth ground

 (Fig. 1-4, pgs. 4-6).

 

Keep power-limited wiring separate from non power-limited wiring. Minimum 0.25” spacing must be provided.  

 

 

Use separate knockouts.

4.  Adjust output voltage (unit is factory set at 12VDC): use the trimpot on the power supply board 
 

prior to connecting CCTV devices.

5.  Measure output voltage before connecting devices. This helps avoiding potential damage.
 

CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the    

 

output voltage.

- 2 - 

ALTV615DC220 Series

Agnecy Listing:

•  CE European Conformity.

Input:

• 220VAC (working range 198VAC-256VAC), 50/60Hz.

Output:

•  Four (4), eight (8), or sixteen (16) individual outputs.
•  6VDC to 15VDC field adjustable.
•  Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
•  Filtered and electronically regulated outputs.

Features:

•  AC input and DC output LED indicators.

Features 

(cont’d)

:

•  Power ON/OFF switch. 
•  Unit maintains camera synchronization.
•   Ease of installation saves time and eliminates 
  costly labor.

Enclosure Dimensions 

(H x W x D approx.)

:

  ALTV615DC44M220, ALTV615DC44CBM220,
  ALTV615DC48M220, ALTV615DC48CBM220,
  8.5” x 7.5” x 3.75” (215.9mm x 190.5mm x 95.25mm)
  All other models:
  13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm)

Door

CAUTION: De-energize unit prior to servicing. For continued protection against fire hazard

replace fuse with the same type and rating. Do not expose unit to rain or moisture.

3.5A 250V

For continuous protection against 

risk of fire replace fuses with

same type and rating.

common 

outputs

protected 

outputs

P

N

N

P

S

XFMR Inpu

t

PD16W

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

N

P

Wire Strap

(from 

Enclosure

to Door)

XFMR

XFMR

 

 

Power Supply

Board

Used on PTC Models

(example: ALTV615DC416CB220)

P

N

PTCs

N

P

S

XFMR Input

PD16W

common 

outputs

protected 

outputs

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

P

N

DC outputs

DC outputs

Power

Switch

220VAC Input

50/60Hz

Summary of Contents for LTV615DC48M220

Page 1: ...6 15VDC 4A Eight 8 Fuse Protected Outputs Eight 8 PTC Protected Outputs ALTV615DC416220 ALTV615DC416CB220 6 15VDC 4A 6 15VDC 4A Sixteen 16 Fuse Protected Outputs Sixteen 16 PTC Protected Outputs ALTV6...

Page 2: ...marked N of the Inlet Appliance Connector Figs 1 4 pgs 4 6 Use 18 AWG or larger for all power connections Units with line cord installed skip Instruction 3 Use 18 AWG or larger for all power connecti...

Page 3: ...DC 15VDC output PD4 PD4CB Distribution Module 1P 4P Positive DC outputs 1N 4N Negative DC outputs PD8 PD8CB Distribution Module 1P 8P Positive DC outputs 1N 8N Negative DC outputs PD16W PD16WCB PD16CB...

Page 4: ...r T im ot A A XFMR INPUT 1P 1N 2P 2N 3P 3N 4P 4N LED 1P 2P 3P 4P FUSED OUTPUTS 1N 2N 3N 4N COMMON OUTPUTS 3 5A 250V 3 5A 250V 3 5A 250V MAIN FUSE ON OFF ON OFF Fig 1 ALTV615DC44M220 ALTV615DC44CBM220...

Page 5: ...rotected outputs P N N P S XFMR Input PD16W 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 N P Wire Strap from Enclosure to Door XFMR XFMR Power Supply Board Used on PTC Models example ALTV615DC416CB220 P N P...

Page 6: ...6 ALTV615DC220 Series Notes...

Page 7: ...5 x 3 75 215 9mm x 190 5mm x 95 25mm 3 63 92 2mm 7 25 184 15mm 7 25 184 15mm 1 25 4mm 1 25 4mm 1 25 4mm 1 75 44 45mm 8 13 206 5mm 8 13 206 5mm 3 85 97 79mm 1 25 4mm 1 25 4mm 1 25 4mm 3 85 97 79mm 1 25...

Page 8: ...closure Dimensions for ALTV615DC416220 ALTV615DC416CB220 ALTV615DC616220 ALTV615DC616CB220 ALTV615DC1016220 ALTV615DC1016CB220 13 5 x 13 x 3 25 342 9mm x 330 2mm x 82 55mm 1 40 36mm 1 40 36mm 4 85 123...

Reviews: