Overview:

Altronix eFlowNBV power supply/chargers convert a 220VAC (working range 198VAC - 256VAC), 50/60Hz input 

to a 12VDC or 24VDC output .

Specifications:

Altronix 

Model Nuber

Input Rating

220VAC 50/60Hz

Output Voltage (Current)

Aux. Output

(unswitched)

Maximum

Charge

Current

12VDC

24VDC

eFlow3NBV

2 .1A

2A

2A

1A

1 .54A

eFlow4NBV

2 .1A

4A

4A

1A

1 .54A

eFlow6NBV

2 .1A

6A

6A

1A

1 .54A

eFlow102NBV

2 .1A

10A

1A

1 .54A

eFlow104NBV

2 .7A

10A

1A

1 .54A

All of the above Power Supply/Chargers can be installed in Trove1 and Trove2 Access and Power Integration 

Systems and Maximal Series .

Features:

Agency Listings:

•  CE European Conformity .

Output:

•  Overvoltage protection .

•  Filtered and electronically regulated outputs .

Battery Backup:

•  Built-in charger for sealed lead acid or 

  gel type batteries .

•  Automatic switch over to stand-by battery when 

  AC fails .

•  Transfer to stand-by battery power is instantaneous 

  with no interruption .

Fire Alarm Disconnect:

•  Supervised Fire Alarm disconnect (latching or non-

  latching) 10K EOL resistor . Operates on a normally 

  open (NO) or normally closed (NC) trigger .

Supervision:

•  AC fail supervision (form “C” contacts) .

•  Battery fail and presence supervision 

  (form “C” contacts) .

•  Low power shutdown . Shuts down DC output 

  terminals if battery voltage drops below 80% of 

  nominal . Prevents deep battery discharge .

Visual Indicators:

•  Green AC Power LED indicates 220VAC present .

•  AC input and DC output LED indicators .

Additional Features:

•  Short circuit and overload protection .

Board Dimensions 

(approximate L x W x H)

:

  eFlow3NBV, eFlow4NBV, 

  eFlow6NBV, eFlow102NBV:

  7 .5” x 4 .6” x 1 .75”

  (190 .5mm x 116 .8mm x 44 .5mm)

 eFlow104NBV:

  8 .25” x 4 .56” x 1 .5” 

  (209 .5mm x 115 .8mm x 38 .1mm) .

Summary of Contents for eFlowNBV Series

Page 1: ...er Supply Charger Boards Models Include Installation Guide Rev EFNBV 061418 More than just power TM eFlow3NBV 12 or 24VDC 2A eFlow4NBV 12 or 24VDC 4A eFlow6NBV 12 or 24VDC 6A eFlow102NBV 12VDC 10A eFl...

Page 2: ...nts Overview pg 3 Specifications pg 3 Features pg 3 Stand by Specifications pg 4 Installation Instructions pg 5 eFlowNBV configuration pg 5 Wiring pg 6 Maintenance pg 6 LED Diagnostics pg 6 Terminal I...

Page 3: ...uts Battery Backup Built in charger for sealed lead acid or gel type batteries Automatic switch over to stand by battery when AC fails Transfer to stand by battery power is instantaneous with no inter...

Page 4: ...Battery Burg Applications 4 hr Stand by 15 min Alarm Fire Applications 24 hr Stand by 5 min Alarm Access Control Applications Stand by 7AH 0 4A 6A 10 Mins 6A 12AH 1A 6A 0 3A 6A 35 Mins 6A 40AH 6A 6A 1...

Page 5: ...g 5 For auxiliary device connection this output will not be affected by Low Power Disconnect or Fire Alarm Interface Connect device to terminals marked AUX Fig 1f pg 5 6 For Access Control application...

Page 6: ...nect 220VAC 50 60Hz to these terminals L to hot N to neutral G to ground Fig 1a pg 5 DC Fig 1h pg 5 eFlow3NBV 12VDC or 24VDC 2A continuous output power limited output eFlow4NBV 12VDC or 24VDC 4A conti...

Page 7: ...Guide 7 Notes Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix co...

Page 8: ...al or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state change...

Reviews: