background image

 

ALTV244220 Series 

- 7 -

Enclosure Dimensions 

(H x W x D)

 for:

• ALTV244220 
• ALTV244CB220

8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)

1.25”

(31.75mm)

1.25”

(31.75mm)

1.25”

(31.75mm)

1.125”

(28.575mm)

1”

(25.4mm)

1”

(25.4mm)

1”

(25.4mm)

5.25”

(133.35mm)

6.05”

(153.67mm)

6.05”

(153.67mm)

3.5”

(88.9mm)

3.5”

(88.9mm)

7.25”

(184.15mm)

2”

(50.8mm)

2”

(50.8mm)

8.125”

(206.375mm)

0.6”

(15.24mm)

1”

(25.4mm)

1”

(25.4mm)

0.6”

(15.24mm)

0.6”

(15.24mm)

1.125”

(28.575mm)

0.6”

(15.24mm)

3.625”

(184.15mm)

Summary of Contents for ALTV244220 Series

Page 1: ...100VA Four 4 Fuse Protected Outputs Four 4 PTC Protected Outputs ALTV244175220 ALTV244175CB220 24VAC 7 25A 175VA or 24VAC 7 25A 175VA or or 28VAC 6 25A 175VA 28VAC 6 25A 175VA Four 4 Fuse Protected Outputs Four 4 PTC Protected Outputs ALTV244300220 ALTV244300CB220 24VAC 12 5A 300VA or 24VAC 12 5A 300VA or 28VAC 10A 300VA 28VAC 10A 300VA Four 4 Fuse Protected Outputs Four 4 PTC Protected Outputs ...

Page 2: ...rews Enclosure Dimensions pg 7 8 Secure enclosure to earth ground 2 Slide switch SW1 to the OFF position on models ALTV244220 and ALTV244CB220 Fig 1 pg 4 Turn main switch on all other models to the OFF position Figs 2 3 pgs 5 6 3 All units are factory set for 24VAC operation For 28VAC operation adjust unit prior to mounting and applying power as follows Change the wire position so that the black w...

Page 3: ...ng equipment Troubleshooting 1 Blown fuse ALTV244220 ALTV244175220 ALTV244300220 Set ON OFF switch to the OFF position Replace the blown fuse s with fuse s rated 3 5A 250VA Altronix model Fuse1 2 Tripped PTC ALTV244CB220 ALTV244175CB220 ALTV244300CB220 To reset PTC set ON OFF switch to the OFF position After approximately 30 secs set ON OFF switch to the ON position WARNING To reduce the risk of f...

Page 4: ...0 5A 1A 250V PTC used on ALTV244CB220 1P 1N 2P 2N 3P 3N 4P 4N POWER DISTRIBUTING UNIT PD4A MAIN FUSE INPUT ON OFF Fig 1 ALTV244220 and ALTV244CB220 N P S N P S 24VAC Output Yellow Black Black Yellow 28VAC Output Voltage Selection Configuration ...

Page 5: ...V Illuminated Power Switch 1P 1N 2P 2N 3P 3N 4P 4N POWER DISTRIBUTING UNIT PD4A MAIN FUSE PTC used on ALTV244175CB220 Fig 2 ALTV244175220 and ALTV244175CB220 N P S N P S 24VAC Output Yellow Black Black Yellow 28VAC Output Voltage Selection Configuration ...

Page 6: ...300CB220 Input 220VAC 50 60Hz 1 8A 4A 250V 1P 1N 2P 2N 3P 3N 4P 4N POWER DISTRIBUTING UNIT PD4A MAIN FUSE Illuminated Power Switch PTC used on ALTV244300CB220 N P S N P S 24VAC Output Yellow Black Black Yellow 28VAC Output Voltage Selection Configuration ...

Page 7: ... 190 5mm x 88 9mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 1 125 28 575mm 1 25 4mm 1 25 4mm 1 25 4mm 5 25 133 35mm 6 05 153 67mm 6 05 153 67mm 3 5 88 9mm 3 5 88 9mm 7 25 184 15mm 2 50 8mm 2 50 8mm 8 125 206 375mm 0 6 15 24mm 1 25 4mm 1 25 4mm 0 6 15 24mm 0 6 15 24mm 1 125 28 575mm 0 6 15 24mm 3 625 184 15mm ...

Page 8: ...ies E08R MEMBER Enclosure Dimensions H x W x D for ALTV244175220 ALTV244175CB220 ALTV244300220 ALTV244300CB220 8 5 x 7 5 x 3 875 215 9mm x 191mm x 98 4mm 3 63 92 2mm 7 25 184 15mm 7 25 184 15mm 1 25 4mm 1 25 4mm 1 25 4mm 1 75 44 45mm 8 13 206 5mm 8 13 206 5mm 3 85 97 79mm 1 25 4mm 1 25 4mm 1 25 4mm 3 85 97 79mm 1 25 4mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 3 85 97 79mm 0 6 15 24mm 0...

Reviews: