ALTV2432UL3 Series

Overview:

Altronix ALTV2432UL3 Series CCTV Power Supplies provide 24VAC or 28VAC distributed via thirty-two 
(32) fuse or PTC protected outputs for powering CCTV cameras, heaters and other video accessories.

Thirty-Two (32) Output ALTV2432UL3 Reference Chart:

Altronix 
Model Number

Output Voltage

Total 

 Output Current 

(Power)

Number of Outputs

PTC Protected auto-

resettable Outputs 

(Class 2 Rated power- 

imited for Dry locations, 

Class 3 for Wet locations)

Fuse Protected 

Class 1 Outputs

Individual Output

Current (max per

output, not to exceed

total output current)

Fuse Ratings

Main Fuse Ratings

115VAC 60Hz

Input Current

Agency

Listings

ALTV2432300UL3

24VAC 12.5A

32

P

3.5A

3.5A

2.7A

28VAC

10A

ALTV2432300ULCB3

24VAC 12.5A

32

P

2.5A

2.7A

28VAC

10A

ALTV2432600UL3

24VAC

25A

32

P

3.5A

3.5A

5.4A

28VAC

20A

ALTV2432600ULCB3

24VAC

25A

32

P

2.5A

5.4A

28VAC

20A

Specifications:

Agency Listings:

•  UL Listed for Commercial CCTV Equipment 
  (UL 2044). 
  CUL Listed - CSA Standard C22.2 No.1-98, 
  Audio, Video and Similar Equipment. 
•  CE European Conformity.

Input:

•  115VAC, 50/60Hz.

Output:

•  Thirty-two (32) fuse or PTC protected outputs. 
•  24VAC or 28VAC output
•  Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
•  Surge suppression.

Features:

•  AC power LED indicator.
•  Illuminated power disconnect circuit breaker 
 

with  manual  reset.    

•  Unit maintains camera synchronization.
•  Ease of installation saves time and eliminates 
  costly labor.
•  Spare fuses included (on fuse protected models).
•  Factory installed 3-wire line cord.

Enclosure Dimensions 

(H x W x D)

:

  13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm).

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with 
all local codes and authorities having jurisdiction. Product is intended for indoor use only. 
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes 
  in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place 
  the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower 
  two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s 
  upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws 
  (Enclosure Dimensions, pg. 8). Secure enclosure to earth ground.
2. Turn OFF main switch on the unit (Figs. 1 - 2, pgs. 4 - 5).
3. All units are factory set for 24VAC operation. 
  For 28VAC operation (where available) adjust unit prior to mounting and applying power as follows: 
  Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and 
  the yellow wire [24V] is connected to the terminal marked [S].
4. Plug-in 3-wire line cord (Figs. 1 - 2, pgs. 4 - 5).
  Keep power-limited (PTC protected outputs only) wiring separate from non power-limited wiring. 
  Minimum 0.25” spacing must be provided. Use separate knockouts.
5. Measure output voltage before connecting devices. This helps avoid potential damage.
 

CAUTION: Determine the maximum operating voltage of the equipment being powered before 

  adjusting the output voltage.