background image

 

- 12 - 

M220 Series

Fig. 8

TRIGGER

LED

TRIGGER

NEG (-) 

INPUT POS 

(+

)

POWER
ON LED

N.C.

RESET

EOL 2.2K

(+)

(-)

DC VOLTAGE INPUT

FROM FACP

SIGNALING OUTPUT

N.O. INPUT

FROM FACP

SIGNALING

OUTPUT

NC   C   NO

DRY OUTPUT

NC   C   NO

POWER FAIL

TRIGGER

LED

TRIGGER

NEG (-) 

INPUT POS 

(+

)

POWER
ON LED

N.O. RESET

EOL 2.2K

(+)

(-)

DC VOLTAGE INPUT

FROM FACP

SIGNALING OUTPUT

N.C. INPUT

FROM FACP

SIGNALING

OUTPUT

NC   C   NO

DRY OUTPUT

NC   C   NO

POWER FAIL

MOM5 module shown with with wet and/or dry 
normally open fire alarm trigger inputs 
(Latching with Manual Reset):

MOM5 module shown with with wet and/or dry 
normally closed fire alarm trigger inputs 
(Latching with Manual Reset):

Typical Application Diagrams 

(cont’d)

:

TRIGGER

LED

TRIGGER

- DC INPUT+

NEG 

(-) 

INPUT 

POS 

(+)

POWER
ON LED

TRIGGER

LED

TRIGGE

R

- DC INPUT+

NEG 

(-) 

INPUT 

POS 

(+)

POWER
ON LED

N.O. RESET

EOL 2.2K

EOL 2.2K

(+) (-)

DC VOLTAGE INPUT

FROM FACP

SIGNALING

OUTPUT OR ACCESS

CONTROL DEVICE

N.C.  INPUT

FROM FACP

NC   C   NO

DRY OUTPUT

NC   C   NO

POWER FAIL

NC   C   NO

DRY OUTPUT

NC   C   NO

POWER FAIL

Fig. 9 - Two (2) MOM5 modules shown with wet and/or dry normally closed fire alarm trigger inputs
 

(Latching with Manual Reset):

TRIGGER

LED

TRIGGER

- DC INPUT+

NEG 

(-) 

INPUT 

POS 

(+)

POWER
ON LED

TRIGGER

LED

TRIGGER

- DC INPUT+

NEG 

(-) 

INPUT 

POS 

(+)

POWER
ON LED

EOL 2.2K

(+)

(-)

(+)

(-)

N.C. RESET

EOL 2.2K

DC VOLTAGE INPUT

FROM FACP

SIGNALING

OUTPUT OR ACCESS

CONTROL DEVICE

N.O.  INPUT

FROM FACP

NC   C   NO

DRY OUTPUT

NC   C   NO

POWER FAIL

NC   C   NO

DRY OUTPUT

NC   C   NO

POWER FAIL

Fig. 10 - Two (2) MOM5 modules shown with wet and/or dry normally open fire alarm trigger inputs
 

 (Latching with Manual Reset):

Summary of Contents for AL1012M220

Page 1: ...cess Control Power Supply Chargers Installation Guide Models Include AL300M220 2 5A 12VDC or 24VDC AL600M220 6A 12VDC or 24VDC AL1024M220 10A 24VDC AL400M220 4A 12VDC or 3A 24VDC AL1012M220 10A 12VDC...

Page 2: ...bove Fire Alarm Panel or Access Control System trigger inputs NO or NC supervised trigger input and polarity reversal trigger input 4mA draw from FACP Output Five 5 individual PTC protected auto reset...

Page 3: ...parts inside Refer installation and servicing to qualified service personnel 5 Connect Fail Secure type locking hardware e g door strikes and electronic dead bolts positive leads to terminals marked 1...

Page 4: ...nt is 0 7A AL1024XB2V Power Supply Board maximum charge current is 3 6A Expected battery life is 5 years however it is recommended to change batteries within 4 years or less if necessary LED Diagnosti...

Page 5: ...witch Position 4 hr of Stand by 5 Minutes of Alarm 24 hr of Stand by 5 Minutes of Alarm 60 hr of Stand by 5 Minutes of Alarm 12VDC 40AH Battery ON Stand by 6 0A Alarm 6 0A Stand by 1 0A Alarm 6 0A Sta...

Page 6: ...o Door Ground Lug Optional Rechargeable Stand by Battery Optional Rechargeable Stand by Battery SW1 ON 1 OFF 24V ON 12V J1 AC Delay Battery AC Supervision Circuit NC C NO NC C NO Keep power limited wi...

Page 7: ...und Lug Optional Rechargeable Stand by Battery Optional Rechargeable Stand by Battery SW1 ON 1 OFF 24V ON 12V Battery AC Supervision Circuit NC C NO NC C NO Keep power limited wiring separate from non...

Page 8: ...isture Keep power limited wiring separate from non power limited Use minimum 0 25 spacing CAUTION Optional rechargeable stand by batteries must match the power supply output voltage setting DC INPUT P...

Page 9: ...p power limited wiring separate from non power limited Use minimum 0 25 spacing CAUTION Optional rechargeable stand by batteries must match the power supply output voltage setting DC INPUT POS DC OUTP...

Page 10: ...3 6A MOM5 Output Module Terminal Legend Function Description DC INPUT 12VDC or 24VDC from power supply TRIGGER Dry normally open NO or normally closed NC supervised 2 2K EOL resistor input trigger A...

Page 11: ...POWER FAIL TRIGGER NEG INPUT POS EOL 2 2K DC VOLTAGE INPUT FROM FACP SIGNALING OUTPUT OR ACCESS CONTROL DEVICE N C INPUT FROM FACP OR ACCESS CONTROL DEVICE TRIGGER NEG INPUT POS EOL 2 2K DC VOLTAGE IN...

Page 12: ...TRIGGER LED TRIGGER DC INPUT NEG INPUT POS POWER ON LED TRIGGER LED TRIGGER DC INPUT NEG INPUT POS POWER ON LED N O RESET EOL 2 2K EOL 2 2K DC VOLTAGE INPUT FROM FACP SIGNALING OUTPUT OR ACCESS CONTR...

Page 13: ...rm A G Alarm duration Alarm H Hours example 15 Min 0 25 Hour H Battery capacity required for Alarm E F G AH0 I Total calculated battery capacity D H AH J Battery capacity required I 1 8 safety factor...

Page 14: ...14 M220 Series Notes...

Page 15: ...m x 82 6mm 1 40 36mm 1 40 36mm 4 85 123mm 4 85 123mm 1 40 36mm 1 40 36mm 5 10 130mm 5 10 130mm 13 0 330mm 5 10 130mm 6 5625 167mm 1 20 31mm 1 20 31mm 1 20 31mm 3 25 83mm 3 25 83mm 3 25 83mm 3 25 83mm...

Page 16: ...W x D for AL1012M220 AL1024M220 15 5 x 12 x 4 5 393 7mm x 304 8mm x 114 3mm 1 5 38 1mm 1 5 38 1mm 1 5 38 1mm 5 0 127 0mm 5 0 127 0mm 1 5 38 1mm 2 0 50 8mm 2 0 50 8mm 1 75 44 45mm 1 75 44 45mm 4 5 114...

Reviews: