background image

ACM4 Series 

- 3 -

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local 
codes and authorities having jurisdiction. Product is intended for indoor use only. 
1. Refer to Sub Assembly Installation Instruction for mounting Rev. MS050913.
  Carefully review: 
  Typical Application Diagram   (pg. 4) 

Terminal Identification Table  (pg. 5)

  LED Diagnostics  

(pg. 5) 

Hook-up Diagrams  

(pg. 6)

2. 

Power supply input:

  The units can be powered with one (1) Listed Access Control Power Supply which will provide power for 
  both board operation and the locking devices or two (2) separate Listed Access Control Power Supplies, 
  one (1) to provide power for the board operation and the other to provide power for the locking devices 
  and/or access control hardware.
 

Note: The input power can be either 12 to 24 volts AC or DC operation.

  Input Ratings (ACM4/ACM4CB only): 12VDC @ 0.4A or 24VDC @ 0.2A.
  a) Single power supply input:
  If the unit and the locking devices are to be powered using a single Listed Access Control Power Supply, 
  connect the output (12 to 24 volts AC or DC) to the terminals marked [- C].
  b) Dual power supply inputs (Fig. 1, pg. 5):
  When the use of two Listed Access Control Power Supplies is desired, jumpers J1 and J2 (located to the 
  left of the power/control terminals) must be cut. Connect power for the unit to the terminals marked 
  [- C] and connect power for the locking devices to the terminals marked [- Power +].
 Note: 

When using DC Listed Access Control Power Supplies polarity must be observed. 

  When using AC Listed Access Control Power Supplies polarity need not be observed.
 

Note: For UL compliance the power supplies must be UL Listed for Access Control Systems and accessories.

3. 

Output options (Fig. 1, pg. 5):

 The ACM4 will provide either four (4) switched power outputs, four (4) dry form “C” outputs, or any com-
  bination of of both switched power and form “C” outputs, plus four (4) unswitched auxiliary power outputs.
  The ACM4CB will provide four (4) switched power outputs or four (4) unswitched auxiliary power outputs.
  a) Switched Power outputs: 
  Connect the negative (-) input of the device being powered to the terminal marked [COM]. For Fail-Safe  
  operation connect the positive (+) input of the device being powered to the terminal marked [NC]. For 
  Fail-Secure operation connect the positive (+) input of the device being powered to the terminal marked [NO].
  b) Form “C” outputs (ACM4):
  When form “C” outputs are desired the corresponding output fuse (1-4) must be removed. Connect 
  negative (-) of the power supply directly to the locking device. Connect the positive (+) of the power supply 
  to the terminal marked [C]. For Fail-Safe operation connect the positive (+) of the device being powered to 
  the terminal marked [NC]. For Fail-Secure operation connect the positive (+) of the device being powered 
  to the terminal marked [NO].
  (c) Auxiliary Power outputs (unswitched):
  Connect positive (+) input of the device being powered to the terminal marked [C] and the negative (-) of 
  the device being powered to the terminal marked [COM]. Output can be used to provide power for card 
  readers, keypads etc.
 Note: When wiring for power-limited outputs utilize a knockout separate from the one used for 
  non power-limited wiring.
4. 

Input trigger options (Fig. 1, pg. 5):

  (a) Normally Open [NO] input trigger:
  Inputs 1-4 are activated by normally open or open collector sink inputs.
  Connect devices (card readers, keypads, request to exit buttons etc.) to terminals marked [IN] and [GND]. 
  (b) Open Collector Sink inputs:
  Connect the access control panel open collector output to the terminal marked [IN] and the 
  common (negative) to the terminal marked [GND].
5. 

Fire Alarm Interface options (Figs. 3 through 7, pg. 6)

  A normally closed [NC], normally open [NO] input or polarity reversal input from FACP signaling circuit 
 will trigger selected outputs. To enable FACP Disconnect for an output open the corresponding switch 
  [SW1-SW4]. To disable FACP disconnect for an output close the corresponding switch [SW1-SW4].

  a) Normally Open [NO] input:

  For non-latching hook-up see Fig. 4, pg. 6. For latching hook-up see Fig. 5, pg. 7.

  b) Normally Closed [NC] input:

  For non-latching hook-up see Fig. 6, pg. 7. For latching hook-up see Fig. 7, pg. 7.

Summary of Contents for ACM4 Series

Page 1: ...ACM4 Series UL Listed Sub Assembly Access Power Controllers Installation Guide Models Include ACM4 Four 4 Fuse Protected Outputs ACM4CB Four 4 PTC Protected Outputs Rev 051311 More than just power...

Page 2: ...s Control System Units UL 294 Signal Equipment Evaluated to CSA Standard C22 2 No 205 M1983 Specifications 12 to 24 volt AC or DC operation setting not required Input Ratings 12VDC 0 4A or 24VDC 0 2A...

Page 3: ...ide four 4 switched power outputs or four 4 unswitched auxiliary power outputs a Switched Power outputs Connect the negative input of the device being powered to the terminal marked COM For Fail Safe...

Page 4: ...interface has to be simulated LED Diagnostics LED ON OFF LED 1 LED 4 Red Output relay s energized Output relay s de energized TRG Green FACP input triggered alarm condition FACP normal non alarm condi...

Page 5: ...Panel Output Relay Mag Lock Mag Lock Electric Strike Electromagnetic Door Holders Listed AC or DC Access Control Power Supply optional FACP Fire Alarm Control Panel Listed AC or DC Access Control Powe...

Page 6: ...CONTROL CIRCUIT EOL if employed NO C NC FACP INP T RET INTERFACE TRG J3 Hook up Diagrams Fig 2 Optional hook up using two 2 isolated power supply inputs CUT JUMPERS J1 AND J2 ISOLATED POWER INPUT 12...

Page 7: ...TERFACE TRG J3 N C RESET SWITCH N O TRIGGER INPUT JUMPER NO C NC FACP INP T RET INTERFACE TRG J3 JUMPER N C DRY TRIGGER INPUT Fig 6 Normally Closed Non Latching FACP trigger input NO C NC FACP INP T R...

Page 8: ...l error Product specifications are subject to change without notice 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com L...

Reviews: