6062 Typical Applications:
For this application Switch #1 and Switch #4
should be in the OFF position.
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 2 - Guard Tour Supervisory Timer:
Fig. 6 - Timed Shunt for a Door: Use to bypass alarm contacts.
TRG
--
+
Closed
Circuit
Contact
Pull up
Resistor
Power
Supply
+
---
TRG
--
+N
OC
NC
1
ON
ON
1 2 3 4
OFF
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELA
Y CONTROL
CHIME
Pos (+) and Neg (-- )
terminals constant
12VDC or 24VDC
Normally Open
Door Contacts
+
---
+
---
4
3
2
1
J3
CUT J2 FOR DELA
Y PULSE J2
CUT J1 FOR REPEA
T J1
45
60
TRG
--
+N
OC
NC
1
ON
ON
1 2 3 4
OFF
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELA
Y CONTROL
Pos (+) and Neg (-- )
terminals constant
12VDC or 24VDC
Normally Open
Door Contacts
Door Strike
+
---
+ ---
4
3
2
1
J3
CUT J2 FOR DELA
Y PULSE J2
CUT J1 FOR REPEA
T J1
45
60
TRG
--
+N
OC
NC
1
ON
ON
1 2 3 4
OFF
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELA
Y CONTROL
DIALER OR
TRANSMITTER
Pos (+) and Neg (-- )
terminals constant
12VDC or 24VDC
Normally Open
Switch Contacts
+
---
4
3
2
1
J3
CUT J2 FOR DELA
Y PULSE J2
CUT J1 FOR REPEA
T J1
45
60
TRG
--
+N
OC
NC
1
ON
ON
1 2 3 4
OFF
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELA
Y CONTROL
Pos (+) and Neg (-- )
terminals constant
12VDC or 24VDC
Door Contacts
Protective
Circuit
+
---
4
3
2
1
J3
CUT J2 FOR DELA
Y PULSE J2
CUT J1 FOR REPEA
T J1
45
60
Normally Open
Switch Contacts
TRG
--
+N
OC
NC
1
ON
ON
1 2 3 4
OFF
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELA
Y CONTROL
Closed
Circuit
Zone on
Control Panel
Pos (+) and Neg (-- )
terminals constant
12VDC or 24VDC
Protective
Circuit
+
---
4
3
2
1
J3
CUT J2 FOR DELA
Y PULSE J2
CUT J1 FOR REPEA
T J1
45
60
TRG
--
+N
OC
NC
1
ON
ON
1 2 3 4
OFF
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELA
Y CONTROL
Use appropriate contacts
to reporting devices
Normally Open
Triggering Device
Pos (+) and Neg (-- )
terminals constant
12VDC or 24VDC
+
---
4
3
2
1
J3
CUT J2 FOR DELA
Y PULSE J2
CUT J1 FOR REPEA
T J1
45
60
TRG
--
+N
OC
NC
1
ON
ON
1 2 3 4
OFF
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELA
Y CONTROL
Bell
or
Siren
+
---
4
3
2
1
J3
CUT J2 FOR DELA
Y PULSE J2
CUT J1 FOR REPEA
T J1
45
60
Bell
Output
Control Panel
12VDC or 24VDC
Fig. 1 - Timed Door Annunciator:
Fig. 5 - Timed Door Strike:
For this application Switch #1 and Switch #4
should be in the OFF position.
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 3 - Swinger Eliminator:
Fig. 7 - Bell Cut Off Timer:
For this application Switch #1 should be in the OFF position
and Switch #4 should be in the ON position.
For this application Switch #1 should be in the ON position
and Switch #4 is not used in this application.
Fig. 4 - Delay Timer: Use for Door Ajar Alarm, Delayed
Activation of Digital Dialer, Defrost Cycle Timer, etc...
Fig. 8 - Closed Circuit Trigger Option:
For this application Switch #1 should be in the ON
position and Switch #4 is not used in this application.
For this application a resistor [for 12VDC - 2K (2,000 ohm)
or for 24VDC - 4.7K (4,700 Ohm)] must be installed as
shown (resistor not supplied).