SAMPLE AIR – the adjusted jet size, based on the current ADR, will
automatically be shown in the lower right corner of the display as
JS=XXX.X
PREDICT – will display the type of jet followed, by the base settings,
and then prompt for input of the new ADR. After the ADR is entered the
adjusted Jet Size will be displayed.
Example:
Holley
Base ADR=X.XXX BASE JET=XXX.X
New ADR=X.XXX
JET SIZE=XXX.X
EZ PLATE MODE
: By pressing "4" sets the unit to the PLATE MODE.
PLATE MODE
Index = 9.90
CHANGE?
YES = 1 NO = 2
If the user presses "1" the following will be displayed:
ENTER INDEX
Now the user can enter an index, such as 8.90, then he must press the
ENTER key.
SELECT SERIES
4150 = 1
4500 = 2
Next you can select which Plate series you use by pressing 1 or 2.
Predict with
DA=1 OA=2
CF=3 VP=4
Now you must choose which weather variable to reference your
prediction against. The standard is to use DA or OA (if the unit is
oxygen sensor equipped), but you can select CF or VP if you wish.