Decimal point location for Analog Channel 91;
range from 0-3

40125

Decimal point location for Analog Channel 90;
range from 0-3

40124

Decimal point location for Analog Channel 30;
range from 0-3

40123

Decimal point location for Analog Channel 27;
range from 0-3

40122

Decimal point location for Analog Channel 26;
range from 0-3

40121

range from 0-3

Identification:

In addition to the above, the DE-1500 will respond to function code 17 with an
identification string as follows:

Query:

NN 17 CRC CRC

NN = node number, 17 = ID function code, CRC CRC =  two byte
Modbus RTU CRC.

Response:

NN 17 07 D E - 1 5 0 0 CRC CRC

NN = node number, 17 = ID fucntion code, 07 = number of bytes
to follow, DE-1500 ( seven byte ASCII ID string ), CRC CRC =
two byte Modbus RTU CRC

Stop/Reset:

Register 40999 can be written to to remotely trigger the STOP & RESET
functions. It will only respond to a single write ( function code 06 ). The stop
Command is 0xAC53. The reset command is 0xBE41.

Remote Keypad Emulation:

The DE has a feature called the "Remote Keypad Emulation" that can be accessed
through function code 20 as follows

Query:

NN 20 KP CRC CRC

NN = node number, 20 = KP function code, KP is the single byte
"Key Press" from the table below, CRC CRC =  two byte Modbus
RTU CRC.

"Key Press" Table
00 = NONE ( no keypress, returns
current display )

Summary of Contents for DE-1500

Page 1: ...nsists of the node number associated with the particular DE 1500 The range is from 01 to 99 SPACE 4 7 ASCII value 20h COMMAND 5 6 The letters D and L which stand for data log REQUESTED RECORD NUMBER 8...

Page 2: ...L4 222 223 2 CR LF 202 221 20 EGT1 1022 F VIEW scn 1 L3 200 201 2 CR LF 180 199 20 MAT1 145 F VIEW scn 1 L2 178 179 2 CR LF 158 177 20 VAC1 67 9 PSIG VIEW scn 1 L1 156 157 2 CR LF 136 155 20 MAP1 12...

Page 3: ...on label name Location 12 16 occupy the analog value 100 4 Location 17 contains a space Location 18 20 contain the units of measure PSI TABLE II 203 204 2 CR LF 198 202 177 202 26 NOT USED SERV MSG 3...

Page 4: ...MSG 6 259 260 2 CR LF 254 258 233 258 26 NOT USED SERV MSG 5 231 232 2 CR LF 226 230 205 230 26 NOT USED SERV MSG 4 The CHARACTER LOCATION for the service messages consists of 20 characters which was...

Page 5: ...elow Key Press Table 0 NONE no keypress returns current display C CANCEL TIMERS T TEST R RESET S STOP P VIEW N NEXT U UP UNITS V VIEW CHAN 1 F1 A RIGHT TENS X ENTER L LEFT TENS 2 F2 M MENU D DOWN UNIT...

Page 6: ...point location for Analog Channel 20 range from 0 3 0 no decimal place 1 1 decimal place etc 40115 Current Channel 91 range from 0 to 100 40110 Current Channel 90 range from 0 to 100 40109 RPM Channel...

Page 7: ...two byte Modbus RTU CRC Response NN 17 07 D E 1 5 0 0 CRC CRC NN node number 17 ID fucntion code 07 number of bytes to follow DE 1500 seven byte ASCII ID string CRC CRC two byte Modbus RTU CRC Stop R...

Page 8: ...14 MENU 15 DOWN UNITS 16 ESC Response NN 20 88 20bytes 1st line of display CR LF 20 bytes 2nd line CR LF 20bytes 3rd line CR LF 20bytes 4th line CR LF CRC CRC NN node number 20 KP fucntion code 88 nu...

Reviews: