Altronic 6715 D Manual Download Page 9

 

6715D/Rev. Jul.2020 

Page 9 

Altronic Research Inc. 

switch is "ON" or when one of the fan thermostats senses a temperature equal to or greater 
than 120

°

 (

±

 7

°

) F. 

 
 

The transmitter interlock circuit consists of two thermal switches wired in series to control 
the interlock relay.  Power is supplied to this relay whenever the equipment is attached to 
the correct power supply and the motor temperature senses a temperature equal to or less 
than 160°F and the resistor compartment temperature switch senses a temperature equal to 
or less than 250°(±7°)F.  A lamp is provided to indicate when one or more of the over- 
temperature switches opens.  It is labeled "OVERHEAT", indicating a change in state of 
the interlock.

 

 
1-6. Mechanical Description.

  The Model 6715D RF Coaxial Load is a 50-ohm non-reactive 

resistor assembly which is cooled by forced ambient air.  The blower assembly is a 1/3 HP 
direct-drive centrifugal blower depending on the voltage rating of the load.  The blower 
moves air from floor level into a closed plenum surrounding the resistor assembly.  Air then 
enters the resistor assembly and flows downward through it to the transition duct and then 
out of the enclosure via the discharge grill.  This places the RF input connector at the 
coolest point in the air stream and affords exceptionally quiet operation. 

 

1-7.

 

General Principle of Operation.  

After ascertaining that the Model 6715D is connected 

to the correct power supply, connect the transmitter interlock circuit and RF source.  Turn 
the main power switch ON to start the fan and enable the transmitter.  Operate the 
transmitter as desired.  To stop operation, it is necessary to first turn off the transmitter, 
then the main power switch on the Model 6715D.  The fan may continue to run for some 
time.  This depends upon the power level at which the load was operating and upon the 
ambient air temperature.  This feature is necessary to prevent damage to the load.  The 
Model 6715D can be operated in a "Standby" or "Reject" mode with the blower off.  
Current draw in this mode is 60 milliamperes.  To operate in this mode, connect the unit 
as before and leave the main power switch on the front panel "Off".  It is highly 
recommended that the normally open pair on the interlock terminal board be used to 
control a user-supplied alarm circuit.  This pair will close on power failure or overheat 
and the alarm, if independent of the AC power supply for the unit, will notify the 
operator of a fault. 

 

1-8.

 

Operating and Adjustment Controls.

  The only operating control is the main power 

switch.  No field adjustments are necessary or possible.  

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 6715 D

Page 1: ...ALTRONIC RESEARCH INC P O BOX 249 YELLVILLE ARKANSAS U S A 72687 0249 PHONE 870 449 4093 FAX 870 449 6000 1 800 482 LOAD 5623 in US altronic com MODEL 6715 D COAXIAL LOAD RESISTOR...

Page 2: ...6715D Rev Jul 2020 Page 2 Altronic Research Inc MODEL 6715D 15 KW DIGITAL UHF AIR COOLED COAXIAL RESISTOR...

Page 3: ...ement fails to be a satisfactory solution our limit of obligation shall be no more than full refund of the purchase price This warranty is limited to products of our own manufacture Equipment and comp...

Page 4: ...echanical Description 9 1 7 General Principle of Operation 9 1 8 Operating and Adjustment Controls 9 1 9 Operator Training 10 II Test Equipment and Special Tools 2 1 Test Equipment Required 11 2 2 Spe...

Page 5: ...0 Page 5 Altronic Research Inc SECTION PAGE V Maintenance 5 1 Cleaning 16 5 2 Lubrication 16 5 3 RF Circuit 16 VI Diagrams 6 1 Outline and Dimensions 17 6 2 Schematic Diagram 18 6 3 Parts List 19 VII...

Page 6: ...AL PROTECTION TO SHUT OFF FAN WHICH WILL CAUSE DAMAGE TO UNIT PROVISIONS ARE MADE TO TRIP THE INTERLOCK IN THE EVENT OF OVERHEAT BUT THE INTERLOCK MUST BE PROPERLY CONNECTED TO THE RF SOURCE FOR THIS...

Page 7: ...and or cause the unit to fail CAUTION Do not connect the unit to an RF power source without first ensuring that the load is connected to the proper line voltage and that the interlock circuit is prope...

Page 8: ...le phase 50 60 Hz 230 208 230VAC single phase 50 60 Hz 1 3 Equipment Required But Not Supplied The Model 6715D Coaxial Load is complete as supplied but the user must furnish AC Mains input RF input in...

Page 9: ...rill This places the RF input connector at the coolest point in the air stream and affords exceptionally quiet operation 1 7 General Principle of Operation After ascertaining that the Model 6715D is c...

Page 10: ...ent An understanding of the normal and abnormal indications which may be presented at the control point The proper procedures for starting using and stopping the equipment under normal conditions The...

Page 11: ...ial outlet air minus inlet air and ambient air temperature which the equipment is experiencing We recommend the John B Fluke Mfg Co Model 52 or equivalent instrument for this function 2 2 Special Tool...

Page 12: ...pecification sheet at the end of this manual Reading should be 1 ohm If not consult factory 3 3 Pre installation Tests Prior to installation connect the load to AC Mains power for the following tests...

Page 13: ...TTACHED TO THE PROPER AC POWER SUPPLY WITH INTERLOCK CONNECTED WHENEVER THE RF CONNECTOR IS ATTACHED TO THE SOURCE INADVERTENT APPLICATION OF RF POWER TO THE UNIT WITHOUT AC POWER MAY DAMAGE OR DESTRO...

Page 14: ...ible to minimize back pressure Design of the ducting and wall or ceiling penetrations should be referred to a competent heating and air conditioning firm Make up air is a ventilation term used to indi...

Page 15: ...ck Circuit Two thermal switches are connected in series from Control Line 1 to Interlock Relay RY2 terminal 13 These thermal switches are Single Pole Normally Closed and open at a specified temperatur...

Page 16: ...fan and motor by vacuuming Do not use solvents or an air jet as these can damage the motor Remove dirt and dust accumulations from the grills and resistor assembly with an air jet and a soft brush 5 2...

Page 17: ...6715D Rev Jul 2020 Page 17 Altronic Research Inc SECTION VI 6 1 OUTLINE AND DIMENSIONS...

Page 18: ...6715D Rev Jul 2020 Page 18 Altronic Research Inc 6 2 SCHEMATIC DIAGRAM...

Page 19: ...6715D Rev Jul 2020 Page 19 Altronic Research Inc 6 3 REPLACEMENT PARTS LIST MODEL 6715D CONSULT FACTORY...

Page 20: ...ating Sea Level 15 KW Frequency Range UHF Cooling Method Forced Air Ductable Ambient Temperature 30 C to 43 C Fan Assembly 3 4 hp direct drive centrifugal AC Power Requirements 115 VAC 60 Hz 9 Amp 1 P...

Reviews: