26
MOSTOSTAL Plus FRAME SCAFFOLDINGS Assembly Manual
* closed facade, when number of openings is less than 20% of
facade surface
Type of facade filling
Closed facade
Vertical anchoring spacing
8 m
Horizontal anchoring spacing
every second bay
Maximum force in the anchor
(kN)
||
2,8
4,2
Maximum force in the foot
(kN)
Internal
stand
20,5
13
External
stand
34,1
Scaffolding without covering, closed facade*
Gate crossing option
Working platform load of 2 kN/m²
Safety platform 1 kN/m²
* closed facade, when number of openings is less than 20% of
facade surface
Type of facade filling
Closed facade
Vertical anchoring spacing
8 m
Horizontal anchoring spacing
every second bay
Maximum force in the anchor
(kN)
||
2,8
4,2
Maximum force in the foot
(kN)
Internal
stand
14,0
15
External
stand
37,0
Scaffolding without covering, closed facade*
Basic option
Working platform load of 2 kN/m²
Safety platform 1 kN/m²
horizontal brace
pipe
horizontal brace
– anchor fastening two stands
– anchor fastening one stand
– double V-anchor
– single anchor
– vertical brace
– vertical brace from the wall
– protective railings
– horizontal brace
–
double V-anchor, one for 5 bays – horizontally
– anchor fastening two stands
– anchor fastening one stand
– double V-anchor
– single anchor
– vertical brace
– vertical brace from the wall
– protective railings
– horizontal brace
–
double V-anchor, one for 5 bays – horizontally
3 ASSEMBLY OF SCAFFOLDINGS UP TO 34 m HIGH